Curlin Painsmart IOD
The Curlin Infusion pump, an easy-to-use, ambulatory or pole mounted infusion device designed to meet the needs of the hospital or alternate site patient. It operates accurately in any position, has a low rate resolution of 2 microliters, and its small, compact, lightweight design allows mobility for ambulatory patients. The Curlin Infusion pump can be carried in any of the four convenient carryall soft-packs, pole mounted, placed into the locked “safety shells,” or set on a suitable surface for use.
Features
- Small, accurate, ambulatory, volumetric infusion pump that provides reliable and safe delivery of infusion therapies.
- The Info-On-Demand feature of the Curlin Infusion PainSmart™ IOD pump safely provides additional information to the user when the pump is in the “RUN” mode.
- Customized Maximum Basal Rate Limit.
- Customized Maximum Bolus and Dose Limits.
- Customized Lock Level setting.
- Large screen with Tallman Lettering.
- Larger font, single information display.
- Patient side (downstream) “Line Pressure” displayed.
- medLIMITS™ features.
- PCA dose and medLIMITS™ schedules that can be maintained on Repeat.
- Pump will not permit the user to enter any programming value that is outside of its predetermined default range, or further restricted through medLIMITS™.
- Ability, at the institution level, to configure the pump for specific Administration Route or Units of Measure:
- ° Units (Factory, ml, mg, mcg, ml fixed, mg fixed or mcg fixed);
- ° Route (Intravenous, Epidural, Subcutaneous, Intravenous fixed, Epidural fixed or Subcutaneous fixed).
- Patient and therapy specific programming features via the Curlin Infusion BIOMED SETUP and Options Menus (when not limited by the institution).
- Selection by user from three units of delivery, milliliters, milligrams, and micrograms (when not limited by the institution).
- Choice of five or nine digits Clinician Access Code.
- Maintenance Due Date that is automatically set, the first time, after 12 hours of use.
- Shift Totals that can be greater than 24 hours.
- Hourly Totals.
- Automatic scrolling of the programmed prescription with “quick-repeat” function.
- Cost effective, safe and easy-to-load disposable Curlin Infusion administration sets featuring a unique, spring-activated, self-clamping, set-based “Integral Flow-Stop” device that automatically clamps the tubing when the door of the pump is opened and prevents inadvertent fluid flow.
- User-friendly, easy-to-teach programming that shortens staff inservice time and patient teaching time.
- “Helpful” help screens and display messages.
- Three tamper-resistant lock settings to assist in maintaining patient compliance and safety.
- Retention of programmed infusion settings until cleared by the clinician, thus eliminating the need to reprogram before each use.
- Mandatory requirement of two independent key press actions before a running pump can be turned off, thus minimizing the accidental interruption of a therapy in progress.
- Powered by two readily available, cost-effective “C” size alkaline batteries.
- Attractive yet robust design that is impact resistant and water resistant.
- Audio alarms that can be adjusted from 1 (very quiet) to 9 (loudest) to meet specific patient and clinical setting needs but that cannot be totally disabled.
- Four sizes of convenient carry packs to assist the ambulatory patient in maintainingindependence of lifestyle.
- Retained memory features that allow the pump to easily resume a therapy exactly from where it left off when it is interrupted before completion or to repeat a therapy using the same programmed prescription.
- Compact, lockable safety shells that provide additional security when needed and that are designed to be free standing, pole mounted, or placed in the convenient, soft, carry case.
- Backlit illumination for display screen. Backlight remains on continuously if AC Adapter is in use.
- Integral Up as well as Down Occlusion alarms to notify user if an occlusion is present on either side of the pumping chamber.
- Integral High Upstream pressure alarm to notify user of excessive upstream pressure.
- Integral Air-In-Line alarm to notify user of presence of air in the tubing.
- Adjustable Down Occlusion settings of “High” and “Low” to customize the pump’s down pressure requirements.
Call for price:
(855) 477-8866
Description
- Mechanism: Curvilinear peristaltic finger action
- Width: 4 inches
- Height: 5 inches
- Depth: 2.5 inches
- Weight: 18.1 ounces
- Case Material: UL rated flame-retardant, non-toxic high impact plastic
Operating Environment:
- Operating Temperature:
- ± 5% Accuracy: 55° to 90°F
- ±10% Accuracy: 45° to 55°F
- ±10% Accuracy: 90° to 104°F
- Operating Relative Humidity:
- 15 to 95% non condensing
Storage Environment:
- Temperature Range: -20° to 140°F
- Relative Humidity: 5 to 95% non-condensing
Power Requirements:
- 2 “C size” Single-Use Batteries AC Power
Operating Time with Full Charge Batteries:
- Nominal 85 hours at a rate of 2 ml/hr
Internal Memory Battery: 5 years life
Display: Graphic LCD, 4 text fields, 16 characters per field
- Flow Rates: 0.1 to 50 ml/hr
- Bolus Rate: Up to 125 ml/hr
Volume Accuracy:
- ± 5% for volume delivery >1 ml under the following conditions:
- Temperature 55° to 90° F
- Back pressure to 300 mmHg (5.8 PSI)
±10% for volume delivery >1 ml under the following conditions:
- Temperature 45° to 55°F
- Temperature 90° to 104°F
- Back pressure to 750 mmHg (14.5 PSI)
The maximum volume that may be infused under Single Fault Conditions is 0.8 ml. Recommended administration set usage not to exceed 72* hours. *follow standards of practice for set changes
Administration Sets: Proprietary Curlin Infusion non-DEHP, PVC administration sets available in different configurations.
Fill Volume for Administration Sets: Nonfiltered microbore sets ± 4 ml. See individual administration set label for specific fill volume.
Curlin Painsmart IOD
Up Occlusion Detection Time: Microbore tubing with occlusion below spike.
Rate | Time to Alarm |
0.1 ml/hr | <20 minutes |
1 ml/hr | < 4 minutes |
10 ml/hr | <20 seconds |
50 ml/hr | <10 seconds |
Down Occlusion Detection Time: Microbore tubing with occlusion at distal Luer
Rate | Low Pressure | High Pressure |
0.1 ml/hr | <45 min | <1 hr, 30 min |
1 ml/hr | <5 min | <7 min |
10 ml/hr | <20 seconds | <45 seconds |
50 ml/hr | < 5 seconds | <15 seconds |
125 ml/hr | < 3 seconds | < 5 seconds |
Programmable Time (HH:MM)
PCA No time limit
Bolus Volumes
Microbore tubing with occlusion at distal Luer
Low Pressure: <0.1 ml
High Pressure: <0.1 ml