So here you will be able to find the mechanism, width, height, depth, weight and power of B Braun Horizon NXT Infusion Pump Repair.
- Mechanism: Volumetric, Positive Pressure Displacement Reservoir
- Width: 31.5 cm (12.4 in)
- Height: 12.2 cm (4.8 in)
- Depth: 31.5 cm (12.2 in)
- Weight: 5.4 kg (11.9 lbs)
- Power: 90-132 VAC, 30 Watts, 47/63 Hz USA excluding accessories
- Grounding Resistance: Meets UL Standard 544
- Leakage Current: Meets or exceeds UL Standard 544,Section 27.2 and ANSI/AAMI SafeCurrent Limits (7/9/85)
- Battery: 12 V sealed lead-acid battery forambulatory use
- Battery Operating Time: 4 hours at 125 ml/hr
- Rate Range: 0.1 to 999.9 ml/hr in 0.1 increments
- Volume to be Infused Range: 0.1 to 9999.9 ml
- Variable Occlusion Pressure: 75, 100, 200, 300, 400, 500, and 750mmHg
- KVO Rate: 3 ml/hr or selected rate, whichever is lower
- Accuracy: Volume Delivered 5%
- Alarms: Air-in-line, Container Empty, Door Open,Downstream Occlusion, Hold TimeExceeded, Low Battery, Low Flow fromContainer, System Error, UpstreamOcclusion, Set Improperly Loaded
- Memory: Permanent data retention after the pump isturned off unless alternative Data RetentionDefaults have been selected in the BiomedOptions
- Tubing: Horizon cassette tubing
- Compatible Syringes: 3-60 ml any manufacturer
- Modes/Features: Dose Mode with Drug Menu, Primary andPiggyback Modes, Set Time and Volume,Schedule Next Run, Profile Mode forTPN, Program Mode, q(x)º Mode, SiteTrend, Variable Occlusion Pressure,Micro Mode
B Braun Horizon NXT
- Mechanism: Volumetric, Positive PresssureDisplacement Reservoir
- Width: 31.5 cm (12.4 in)
- Height: 12.2 cm (4.8 in)
- Depth: 31.5 cm (12.2 in)
- Weight: 5.4 kg (11.9 lbs)
- Power: 90-132 VAC, 30 Watts, 47/63 Hz USAexcluding accessories
- Grounding Resistance: Meets UL Standard 544
- Leakage Current: Meets or exceeds UL Standard 544,Section 27.2 and ANSI/AAMI SafeCurrent Limits (7/9/85)
- Battery: 12 V sealed lead-acid battery forambulatory use
- Battery Operating Time: 4 hours at 125 ml/hr
- Rate Range: 0.1 to 999.9 ml/hr in 0.1 increments
- Volume to be Infused Range: 0.1 to 9999.9 ml
- Variable Occlusion Pressure: 75, 100, 200, 300, 400, 500, and 750mmHg
- KVO Rate: 3 ml/hr or selected rate, whichever is lower
- Accuracy: Volume Delivered 5%
- Alarms: Air-in-line, Container Empty, Door Open,Downstream Occlusion, Hold TimeExceeded, Low Battery, Low Flow fromContainer, System Error, UpstreamOcclusion, Set Improperly Loaded
- Memory: Permanent data retention after the pump isturned off unless alternative Data RetentionDefaults have been selected in the BiomedOptions
- Tubing: Horizon cassette tubing
- Compatible Syringes: 3-60 ml any manufacturer
- Modes/Features: Dose Mode with Drug Menu, Primary andPiggyback Modes, Set Time and Volume,Schedule Next Run, Profile Mode forTPN, Program Mode, q(x)º Mode, SiteTrend, Variable Occlusion Pressure,Micro Mode