Kangaroo Epump
The Kangaroo™ ePump Enteral Feeding Pump (Model 382400) is a trusted, precision rotary peristaltic feeding pump developed by Kendall/Tyco Healthcare and later carried under the Covidien and Cardinal Health brands. Widely deployed across hospitals, long-term care facilities, nursing homes, and home care settings, the ePump has earned a reputation for straightforward programming, reliable accuracy, and attitude-independent operation — meaning it delivers correctly in any orientation without a drip chamber on the set.
The ePump delivers feeding formula at 1–400 ml/h in 1 ml/h increments with ±10% accuracy, and uses the MISTIC (Magnetic Intelligent Set Type Identification Connector) system to automatically recognize whether a Feed-Only or Feed & Flush pump set is loaded and adjust programming accordingly. The built-in rechargeable NiMH battery provides up to 15 hours of backup power, and the 72-hour feeding history log gives clinicians a clear record of delivered volume. The pump weighs just 2.3 lbs without the pole clamp, making it genuinely portable for ambulatory use.
IPR Medical specializes in sourcing, repairing, and supporting end-of-life platforms like the Kangaroo ePump — keeping your existing fleet running when the OEM has moved on. IPR Medical buys, sells, repairs, and stocks parts for the Kangaroo ePump. Contact us at 855-477-8866 or cs@iprmed.com.
Kangaroo™ ePump Enteral Feeding Pump — Specifications
| Manufacturer | Kendall / Tyco Healthcare (later Covidien / Cardinal Health) |
| Model Number | 382400 (US) / 482400 (International) |
| Device Type | Volumetric Enteral Feeding Pump — Rotary Peristaltic |
| Intended Use | Continuous or intermittent enteral nutrition and hydration; infant through geriatric patients; hospital, home care, long-term care, and ambulatory settings |
| Feed Rate Range | 1–400 ml/h in 1 ml/h increments |
| Volume to Be Delivered (VTBD) | 1–3,000 ml in 1 ml increments |
| Flush Volume Range | 10–500 ml in 1 ml increments (Feed & Flush sets only) |
| Flush Interval Range | 1–24 hours in 1-hour increments |
| Maximum Flush Rate | 1,960 ml/h |
| Accuracy | ±10% or 0.5 ml/h, whichever is larger (bag at 18″ above pump, room temperature 72°F ± 4°F) |
| Occlusion Alarm Threshold | 15 psi |
| Feeding Modes | Continuous; Intermittent (bolus); Keep Tube Open (KTO, 5–240 min) |
| Set Identification System | MISTIC — Magnetic Intelligent Set Type Identification Connector (auto-recognizes Feed-Only vs. Feed & Flush set) |
| Compatible Pump Sets | Kangaroo ePump MISTIC Feed-Only Sets and Feed & Flush Sets (DEHP-free; Anti-Free-Flow; AccuSystem√ design) |
| Display | Large backlit LCD with step-by-step programming prompts; “Stoplight” tri-color LED array (green/yellow/red) for at-a-glance status |
| User Interface | 5-button ATM-style keypad with guided programming prompts |
| History Memory | 72-hour feeding and flushing history log (retained between power cycles) |
| Languages | 16 languages (including English, Spanish, French, Portuguese) |
| Battery | Rechargeable NiMH Battery Pack — up to 15 hours backup at 100 ml/h; recharges continuously when plugged in; 8-hour full recharge time |
| AC Power | 9V DC, 1.5 A via included AC adapter; detachable power cord |
| Weight | 2.34 lbs (without pole clamp) / 2.69 lbs (with pole clamp) |
| Dimensions (H × W × D) | 6.6″ × 6.4″ × 4.6″ (16.8 × 16.3 × 11.7 cm) |
| Mounting Options | Tabletop or IV pole (removable pole clamp included) |
| Attitude Independence | Yes — no drip chamber required; operates in any orientation (ambulatory-compatible) |
| Auto-Prime | Yes — 30-second auto-prime; Hold-to-Prime manual option also available |
| Alarms | Occlusion (upstream/downstream), Empty Bag, Feed/Flush/Flow Error, Pump Set Dislodged, Rotor Error, Battery Low, Pump Set Use >24 Hours; adjustable audible volume |
| Safety Features | Anti-Free-Flow (AFF) system; MISTIC set-type lock; programmable Lock Screen; VTBD over-infusion safeguard; upstream and downstream flow sensing |
| Data Port | DB9 Serial I/O port (manufacturer use; software updates and data retrieval) |
| Standards Compliance | UL60601-1 (E181931); CSA-C22.2 No.601.1-M90; EN60601-1-2 (EMC) |
| OEM Production Status | Discontinued — Cardinal Health ended new ePump capital equipment sales September 2024; feeding sets/accessories end of supply anticipated mid-2025. IPR Medical continues to support existing fleets. |
| FDA Device Corrections / Recalls | Class 2 recalls on record for the ePump platform and associated feeding sets. See Documents tab and contact IPR Medical for guidance. Check FDA resources for the most current information. |
IPR Medical buys, sells, repairs, and stocks parts for the Kangaroo™ ePump Enteral Feeding Pump. Contact us at 855-477-8866 or cs@iprmed.com.
Overview
The Kangaroo™ ePump Enteral Feeding Pump (Model 382400) is a rotary peristaltic volumetric feeding pump originally developed by Kendall under the Tyco Healthcare brand and subsequently sold under the Covidien and Cardinal Health names. For nearly two decades it was one of the most widely deployed enteral feeding pumps in the United States, used in hospitals, nursing homes, home care, and long-term acute care settings. The ePump is built around a philosophy of simplicity and reliability: a five-button interface, guided on-screen prompts, and automatic set identification combine to make programming fast and minimize the risk of user error across skill levels ranging from clinical biomedical engineers down to lay home-care operators.
Feeding Capabilities and Flow Control
The ePump delivers enteral formula at rates from 1 to 400 ml/h in 1 ml/h increments and can be programmed for volumes from 1 to 3,000 ml. It supports three primary operating modes: continuous feeding, intermittent/bolus feeding with programmable intervals, and Keep Tube Open (KTO) mode, which maintains a slow flow for 5–240 minutes to preserve tube patency between scheduled feeds. Accuracy is rated at ±10% or 0.5 ml/h (whichever is larger), measured at standard conditions with the bag positioned 18 inches above the pump — a specification consistent with IEC standards for enteral feeding devices.
When used with compatible Kangaroo ePump Feed & Flush Sets, the pump adds a separate programmable flush channel: flush volumes of 10–500 ml can be scheduled at intervals from 1–24 hours, and the Flush Now feature allows an immediate on-demand flush during a running feed without resetting the main program. Maximum flush delivery rate is 1,960 ml/h. This automation eliminates the need for staff to manually flush tubes between feeds, reducing both workload and the risk of tube occlusion.
MISTIC Smart Set Identification
A standout safety feature of the ePump is its MISTIC (Magnetic Intelligent Set Type Identification Connector) system. When a pump set is loaded, a magnetic identifier in the set’s retainer ring communicates the set type — Feed-Only or Feed & Flush — directly to the pump’s firmware. The user interface then automatically presents only the programming options appropriate for that set type, preventing the accidental programming of a flush routine on a feed-only set. This smart-set architecture reduces programming errors at the point of care without requiring staff to remember which set variant is loaded.
Attitude-Independent Design and Portability
Unlike many older-generation feeding pumps, the Kangaroo ePump’s rotary peristaltic mechanism does not require a drip chamber on the feeding set. This attitude-independent design means the pump delivers accurately in any orientation — upright, tilted, or horizontal — making it genuinely suitable for ambulatory patients wearing the pump in a carry bag or vest, as well as for bedside pole mounting or tabletop placement. At 2.34 lbs without the pole clamp and measuring 6.6″ × 6.4″ × 4.6″, the pump is compact enough for home and ambulatory use without sacrificing clinical-grade performance.
The built-in rechargeable NiMH battery pack provides up to 15 hours of backup power at 100 ml/h, recharging continuously whenever the pump is connected to AC power. An eight-hour charge from fully depleted restores full capacity. The AC adapter outputs 9V DC at 1.5 A through a detachable power cord, and the battery pack itself is a replaceable field-serviceable component.
User Interface, Alarms, and Safety Systems
The ePump’s front panel features five tactile buttons arranged for intuitive step-by-step programming. The backlit LCD screen displays prompts, current settings, the amount fed, remaining VTBD, and flush data — all at a glance. A tri-color LED array (green for running, yellow for informational warnings, red for critical errors) provides quick visual status in bright or darkened rooms, useful in overnight home care settings. Alarm volume is user-adjustable for environments where noise sensitivity matters.
Safety systems include an Anti-Free-Flow mechanism integrated into every compatible pump set, which prevents uncontrolled formula flow if the set is disconnected from the pump. Upstream and downstream flow sensors detect both empty-bag conditions and downstream occlusions, triggering distinct alarm messages (Feed Error, Flow Error, Flush Error) that guide staff directly to the source of the problem. A programmable Lock Screen feature allows facilities to restrict parameter changes during active feeds, and a separate BioTech access screen provides biomedical technicians with internal calibration and service data without exposing clinical menus.
The 72-hour history log stores a running record of delivered feed and flush volumes, giving clinicians documentation of actual delivery versus prescribed volume across the previous three days — without requiring external software or connectivity.
End-of-Life Status and Continued Support
Cardinal Health officially discontinued new Kangaroo ePump capital equipment sales in September 2024, citing global supply chain challenges including aging componentry and discontinued materials. The anticipated end of supply for ePump feeding sets and accessories was mid-2025, with the platform being superseded by the Kangaroo OMNI enteral feeding pump. For facilities that have invested in ePump fleets and wish to continue operating existing equipment rather than transitioning immediately, IPR Medical provides repair services, replacement parts, and refurbished units — extending the useful life of your existing inventory and helping you manage the transition on your own timeline.
FDA Device Corrections and Safety Bulletins
The FDA has classified at least two Class 2 device recalls affecting the Kangaroo ePump platform and its associated feeding sets. One recall (FDA ID 186052) covers the Kangaroo ePump Enteral Feeding Pump and Enteral Feeding Sets; a separate Class 2 recall (FDA ID 178935) involves the Kangaroo ePump Safety Screw Spike with Flush Bag. Class 2 recalls indicate that use of the affected products may cause temporary or medically reversible adverse health consequences, or that the probability of serious adverse health consequences is remote. Facilities should verify whether their specific pump units or set lot numbers are within the scope of these actions by consulting the FDA’s official databases directly.
Action recommended: Facilities currently operating Kangaroo ePump units or using associated feeding sets should confirm their inventory against the recalled product identifiers. Do not discard pumps without consulting the recall action guidance — Class 2 actions typically involve labeling corrections, use instructions, or set-specific corrections rather than pump destruction. Contact IPR Medical at 855-477-8866 or cs@iprmed.com for service and compliance support.
Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information:
IPR Medical — Your Source for the Kangaroo ePump
IPR Medical buys, sells, repairs, and stocks parts for the Kangaroo™ ePump Enteral Feeding Pump. Whether you need a fully refurbished unit to extend an existing fleet, a replacement battery pack, technical service, or guidance on FDA recall compliance for your units, our team has the expertise and inventory to help. We understand that the ePump’s discontinuation creates urgency for facilities managing active patient populations — and we’re here to bridge that gap.
IPR Medical buys, sells, repairs, and stocks parts for the Kangaroo™ ePump Enteral Feeding Pump. Contact us at 855-477-8866 or cs@iprmed.com.
| Weight | 2.3 lbs |
|---|---|
| Dimensions | 6.6 × 6.4 × 4.6 in |
| Condition | Refurbished |
| Product Condition |
- AC Adapter
- Pole Clamp