Infusion Pump Repair

Alaris Medsystem III 2865

$1,895.00

The MedSystem III® (MSIII) multi-channel infusion pump offers clinical versatility in a compact design. It features a customized drug library, three independent fluid delivery channels, and a drug dose calculator for safe and efficient infusion therapy. Its small size enhances flexibility in patient transport and organization of bedside space. Lightweight and portable, the MSIII is ideal for ambulatory, EMT, and air transport use. The pump’s flexible system parameters can be tailored to meet specific patient needs. A unique, easy-to-use pole clamp allows the pump to be attached almost anywhere. Its user-friendly design ensures quick setup and operation. Overall, the MedSystem III® provides a reliable and adaptable solution for diverse infusion needs.

Send In Alaris Medsystem III 2865 for Repair
  • Dimensions: 7.88 in (20.01 cm)  x 6 in (15.24 cm) x 2.10 in (5.33 cm)
  • Weight: Approx.  5.1 lbs. (2.31 kg) including Pole Clamp
  • Occlusion Pressure (Default): 15 psi except for Controller Pressure device type which is 3 ft. H20
  • Operating Temperature: 50-104° F (10° – 40° C)
  • Transport/Storage Temperature: -4 to 131° Fahrenheit (-20 to 55°C)
    • (<95°F or 35°C for optimum battery life)
  • Rate Range: 0.1 – 999 ml/hr (each channel)
  • Volume Range: 0.1 – 9999 ml (each channel)
  • KVO Rate Range: 0.1 – 20.0 ml/hr
  • Rate Accuracy: 1.0 – 999 ml/hr. ±5% with a standard deviation of 1.96 under specified conditions. 0.1 – 0.9 ml/hr. ±10% with a standard deviation of 1.96.
  • Administration Sets: Use only MedSystem III Administration Sets.
  • Batteries: Main – Rechargeable NiCd Battery Pack
    • Memory Back-up – Non rechargeable Lithium
    • Power Consumption: 6 watts AC power. Use only Instrument AC Adapter, Model 1555, 1565, 1560A ordered as part number 2861089.
    • NOTE: Use only approved CareFusion Battery packs.

Alaris Medsystem III 2865

So here you will be able to find the dimensions, weight, standards, case material and operating temperature of Alaris Medsystem III 2865 Infusion Pump Repair.

  • Standards: UL 544, CSA C22.2, No. 125
  • Case Material: Impact resistant poly carbonate/ABS alloy
  • Air-in-Line (Default): 500 μl (except for Neonatal device type which is 50μl)

Battery Charge: A fully charged battery has a minimum of 6 hours running time with all channels running at 125 ml/hr and backlight usage of 2 minutes per hour.

The main battery retains 80% of its capacity after 500 charging cycles, and retains 90% of its capacity after 3 months of continuous AC charging.

NOTE: Replacement of both the main and memory backup batteries must be performed by qualified service technicians.

AC Adapter & Cord Length: Model 1555, 7.5 Vdc @ 1 Amp with 10 ft. cord.

Model 1560A, 7.5 Vdc @ 1.65 Amp with 10.5 ft. cord.

Model 1565C 7.5Vdc @ 1.7Amp with a 10-ft. cord.

AC Power Requirements: Voltage-90 VAC to 132 VAC, Frequency-47 Hz to 63 Hz

Fuses: 3 amp fast-blow internal

Ground Continuity: Maximum 0.9 ohm

Leakage Current: Maximum 100 microamps

Three independent infusion channels
Small, compact size and lightweight design (5.1 lbs.)
Set-based, free-flow protection with needle-free access
Delivers intravenous, intra-arterial, epidural and subcutaneous applications
Infuses a wide range of fluids from various containers, including syringes, utilizing a syringe adapter set
Dose rate calculation, single-page programming, a selectable drug library and titration of drugs by the user in either dose or volumetric rate
Infuses a wide range of fluids from various containers, including syringes, utilizing a syringe adapter set
Non-rechargeable lithium backup battery

Keyphrase Related:

  • Alaris Medsystem III 2865 Infusion Pump
  • Pole Clamp
  • AC Adapter