- Dimension: 89 x 149 x 41 mm (W x L x H)
- Weight: With Battery – 1.28 lbs (0.58 kg). Without Battery – 0.62 lbs (0.28 kg).
- Battery: Li-Ion; 3,000 mAh
- Power supply: 110 – 240 V; 50/60 Hz; 0.3 A max.
- Flow rate: 0.1 – 1,200 ml/h; 0.0 – 100 ml/h in PCA mode
- Accuracy: ± 5%
- Volume: 0.1 – 9,999.0 ml
- KVO rate: 0.1 – 5.0 ml/h
- Pressure: max. 990 mmHg or 19.9 psi adjustable
Trademark Notice: CME, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by CME.
Quick answer: The CME BodyGuard 121 Twins is a dual-channel piston infusion pump that runs two independent regimens from one keypad for antibiotics, chemotherapy, TPN, and PCA, at the bedside or on the go. It delivers 0.1 to 1,200 ml/h with ±5% accuracy and weighs 580 g with battery. Contact IPR Medical for availability and repair.
- Air: ultrasound sensor, threshold value 0.1 -1.0 ml
- Pump system: piston mechanism
- Alarms: end program; battery low; battery empty; air in line; occlusion; door open; pump locked; lock mode; pump unattended; error; check set
- 2 Independent Infusion Channels
- Deliver 2 separate treatment regimens using one keypad.
- Piston Mechanism
- Delivers ± 5 % accuracy and 1.8μl linear infusion even at the low flow rates.
- BodyComm™ Software
- Review patient history with charts and up to 1000 events log or manage pump settings on your PC.
- EMR Ready
- Connect to Electronic Medical Record systems to increase safety and optimize clinical workflow.
Frequently asked questions
Can the BodyGuard 121 Twins run two therapies at the same time?
Yes. It has two independent infusion channels that deliver two separate treatment regimens from one keypad. Each uses a piston mechanism with ±5% accuracy. Flow rates run from 0.1 to 1,200 ml/h, or 0.0 to 100 ml/h in PCA mode, with volumes from 0.1 to 9,999 ml.
Can I review BodyGuard 121 Twins history on a computer?
Yes. BodyComm software lets you review patient history with charts and an event log of up to 1,000 events, or manage pump settings on a PC. The pump is also EMR ready, so it can connect to electronic medical record systems to support safety and clinical workflow.
Does IPR Medical service the BodyGuard 121 Twins?
IPR Medical repairs infusion pumps in-house; call (855) 477-8866 to confirm service for your 121 Twins. U.S. customers can request a free inbound FedEx or UPS shipping label through our RMA form, approve a written estimate before any work, and receive a 90-day warranty on completed repairs.
Repair service: IPR Medical also repairs this type of equipment in house, with a free shipping label, a free evaluation and a 90-day repair warranty. See our repair service.
Trademark Notice: CME, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by CME.
| Weight | 1.2 lbs |
|---|---|
| Dimensions | 5.75 × 3.3 × 1.57 in |
- Charging Station
Reviews
There are no reviews yet.