Infusion Pump Repair

Curlin Painsmart IOD

$1,095.00 Original price was: $1,095.00.$995.00Current price is: $995.00.

The Curlin Infusion Pump is a versatile and user-friendly infusion device designed for both hospital and alternate site patients. It can be used in various positions and offers a low rate resolution of 2 microliters for precise medication delivery. The pump’s compact and lightweight design enhances mobility for ambulatory patients, allowing them to move freely. It can be carried in one of four convenient carryall soft-packs or securely pole-mounted. Additionally, it can be placed into locked “safety shells” or positioned on a suitable surface for stationary use. The pump’s adaptability and high level of accuracy make it a reliable choice for healthcare settings. Its design prioritizes patient convenience and the flexibility required by healthcare providers. Overall, the Curlin Infusion Pump meets the dynamic needs of patients and professionals, ensuring effective and controlled infusion therapy.

Categories: ,
Send In Curlin Painsmart IOD for Repair
  • Dimensions: 4 in ( cm) x 5 in ( cm) x 2.5 in ( cm)
  • Weight: 1.13 lb (0.52 kg)
  • Power RequirementsOperating Time with Full Charge Batteries
    • (2 “C size” Single-Use Batteries AC Power) – Nominal 85 hours at a rate of 2 ml/hr
  • Internal Memory Battery: 5 years life
  • Volume Accuracy:
    • ± 5% for volume delivery >1 ml under the following conditions:
    • Temperature 55° to 90° F
    • Back pressure to 300 mmHg (5.8 PSI)

    ±10% for volume delivery >1 ml under the following conditions:

    • Temperature 45° to 55°F
    • Temperature 90° to 104°F
    • Back pressure to 750 mmHg (14.5 PSI)

    The maximum volume that may be infused under Single Fault Conditions is 0.8 ml. Recommended administration set usage not to exceed 72* hours. *follow standards of practice for set changes

  • PCA No time limit
  • Operating Environment:
    • Operating Temperature:
    • ± 5% Accuracy: 55° to 90°F
    • ±10% Accuracy: 45° to 55°F
    • ±10% Accuracy: 90° to 104°F
    • Operating Relative Humidity:
    • 15 to 95% non condensing
  • Bolus Volumes (Microbore tubing with occlusion at distal Luer)
    • Low Pressure: <0.1 ml
    • High Pressure: <0.1 ml

Curlin Painsmart IOD

So here you will be able to find the specifications of Curlin Painsmart IOD and the curlin medical painsmart iod. Here are the mechanism, width, height, depth, weight and case material of Curlin Painsmart IOD Infusion Pump Repair.

  • Small, accurate, ambulatory, volumetric infusion pump that provides reliable and safe delivery of infusion therapies.
  • The Info-On-Demand feature of the Curlin Infusion PainSmart™ IOD pump safely provides additional information to the user when the pump is in the “RUN” mode.
  • Customized Maximum Basal Rate Limit.
  • Customized Maximum Bolus and Dose Limits.
  • Customized Lock Level setting.
  • Large screen with Tallman Lettering.
  • Larger font, single information display.
  • Patient side (downstream) “Line Pressure” displayed.
  • medLIMITS™ features.
  • PCA dose and medLIMITS™ schedules that can be maintained on Repeat.
  • Pump will not permit the user to enter any programming value that is outside of its predetermined default range, or further restricted through medLIMITS™.
  • Ability, at the institution level, to configure the pump for specific Administration Route or Units of Measure:
  • ° Units (Factory, ml, mg, mcg, ml fixed, mg fixed or mcg fixed);
  • ° Route (Intravenous, Epidural, Subcutaneous, Intravenous fixed, Epidural fixed or Subcutaneous fixed).
  • Patient and therapy specific programming features via the Curlin Infusion BIOMED SETUP and Options Menus (when not limited by the institution).
  • Selection by user from three units of delivery, milliliters, milligrams, and micrograms (when not limited by the institution).
  • Choice of five or nine digits Clinician Access Code.
  • Maintenance Due Date that is automatically set, the first time, after 12 hours of use.
  • Shift Totals that can be greater than 24 hours.
  • Hourly Totals.
  • Automatic scrolling of the programmed prescription with “quick-repeat” function.
  • Cost effective, safe and easy-to-load disposable Curlin Infusion administration sets featuring a unique, spring-activated, self-clamping, set-based “Integral Flow-Stop” device that automatically clamps the tubing when the door of the pump is opened and prevents inadvertent fluid flow.
  • User-friendly, easy-to-teach programming that shortens staff inservice time and patient teaching time.
  • “Helpful” help screens and display messages.
  • Three tamper-resistant lock settings to assist in maintaining patient compliance and safety.
  • Retention of programmed infusion settings until cleared by the clinician, thus eliminating the need to reprogram before each use.
  • Mandatory requirement of two independent key press actions before a running pump can be turned off, thus minimizing the accidental interruption of a therapy in progress.
  • Powered by two readily available, cost-effective “C” size alkaline batteries.
  • Attractive yet robust design that is impact resistant and water resistant.
  • Audio alarms that can be adjusted from 1 (very quiet) to 9 (loudest) to meet specific patient and clinical setting needs but that cannot be totally disabled.
  • Four sizes of convenient carry packs to assist the ambulatory patient in maintainingindependence of lifestyle.
  • Retained memory features that allow the pump to easily resume a therapy exactly from where it left off when it is interrupted before completion or to repeat a therapy using the same programmed prescription.
  • Compact, lockable safety shells that provide additional security when needed and that are designed to be free standing, pole mounted, or placed in the convenient, soft, carry case.
  • Backlit illumination for display screen. Backlight remains on continuously if AC Adapter is in use.
  • Integral Up as well as Down Occlusion alarms to notify user if an occlusion is present on either side of the pumping chamber.
  • Integral High Upstream pressure alarm to notify user of excessive upstream pressure.
  • Integral Air-In-Line alarm to notify user of presence of air in the tubing.
  • Adjustable Down Occlusion settings of “High” and “Low” to customize the pump’s down pressure requirements.

 

  • Mechanism: Curvilinear peristaltic finger action
  • Case Material: UL-rated flame-retardant, non-toxic high impact plastic

Storage Environment:

  • Temperature Range: -20° to 140°F
  • Relative Humidity: 5 to 95% non-condensing

Administration Sets: Proprietary Curlin Infusion non-DEHP, PVC administration sets available in different configurations.

Fill Volume for Administration Sets: Nonfiltered microbore sets ± 4 ml. See individual administration set label for specific fill volume.

Related Keyphrase:

  • Curlin Painsmart IOD Infusion Pump
  • curlin medical painsmart iod
Condition

Refurbished
Patient Ready

  • AC Power Adapter
  • Bolus/ Patient Cable
  • Lock Box (500 mL)
  • Pole Clamp
  • Holster