Mindray 0010-20-42594 Compatible SpO2 Adapter Cable for Nellcor OxiSmart Sensors, 6-Pin, 7.9 ft
The Mindray 0010-20-42594 compatible SpO2 adapter cable (SKU SA-052-24) is a reusable, aftermarket replacement (not OEM). It connects Nellcor OxiSmart-compatible SpO2 sensors to the compatible Mindray and Datascope monitors listed below.
| Cable Type | SpO2 Adapter (Extension) Cable, Reusable |
| SpO2 Technology | Nellcor OxiSmart Compatible |
| Monitor Connector | 6-Pin |
| Cable Length | 7.9 ft (2.4 m) |
| Replaces | Mindray 0010-20-42594 |
Works with: Datascope Passport XG, DPM1 through DPM5, MEC 100, MEC 200, PM 600, PM 6000 (New), PM 9000 Express, VS 800, and VS 900, plus Mindray Accutorr V, Duo, Trio, Passport V, MEC 1000/1200/2000, PM 7000, PM 8000, PM 9000, and VS-800 monitors. See the Specifications tab for the full list. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SA-052-24 |
| Replaces OEM Part | Mindray 0010-20-42594 |
| Category | SpO2 Adapter (Extension) Cable |
| SpO2 Technology | Nellcor OxiSmart Compatible |
| Monitor Connector | 6-Pin |
| Cable Length | 7.9 ft (2.4 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Mindray | Accutorr V, Duo, MEC 1000, MEC 1200, MEC 2000, Passport V, PM 7000, PM 8000, PM 8000 Express, PM 9000, Trio, VS-800 |
| Mindray (with Nellcor SpO2 Option) | Accutorr V, DPM 3, DPM 4, DPM 5, MEC 1000, MEC 1200, MEC 2000, Passport V, PM 5000, PM 6000, PM 7000, PM 7000 Standard, PM 8000, PM 8000 Express, PM 9000, PM 9000 Express, VS 800 |
| Datascope | 6201, 809B, DPM1, DPM2, DPM3, DPM4, DPM5, MEC 100, MEC 200, Passport XG, PM 600, PM 6000 (New), PM 9000 Express, VS 800, VS 900 |
| Edan | elite V5, elite V8, iM3, iM8, iM8A, iM8B, iM9, iM9A, iM20, iM50, iM60, iM70, iM80, iM80 (without Nellcor OxiMax technology), M3A, M3B, M8, M8A, M8B, M9, M9A, M50, M80 |
| Edan (with Nellcor SpO2 Option) | F9, F9 Express, iM8, iM8A, iM8B, iM9, iM9A, iM50, iM60, iM70, iM80, M3, M3A, M3B, M8, M8A, M8B, M9, M9A, M50, M80 |
| Edan VET (with Nellcor SpO2 Option) | iM8 VET, iM60 VET, iM70 VET, iM80 VET |
| Kontron | 7138, 7840, 7845 |
| Draeger | Vista 120 |
| Philips | M3 |
| Advanced Instrumentations | PM-2000A Pro, PM1000F |
| ARI | 800B |
| CardioTech | GT-900 |
| Carewell | CPM-9000T |
| Contec | CMS 9000 |
| Creative | PC9000, UP-6000 |
| Medec | M-1000, M-1100, MEDEC-1000 |
| Sonolife | SmartWave 7 |
| Venni | VI-3510P, VI-8410P |
| Yonker | YK8000c |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Mindray | 0010-20-42594, 0010-30-43110, 512D-30-16752, 040-001274-00 |
| Draeger | 2606487 |
| DRE | P02796EXT |
| Edan | M13-36091, 01.13.210001-13, 01.13.210001-14, 01.13.036336-11 |
| Kontron | MXC009 |
| Unimed | U708-29 |
IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, including compatible SpO2 adapter cables. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Mindray, Philips, or any other manufacturer or supplier named on this page. Nellcor, Mindray, Philips, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Mindray 0010-20-42594 Compatible SpO2 Adapter Cable?
The Mindray 0010-20-42594 compatible SpO2 adapter cable (SKU SA-052-24) is a reusable, aftermarket replacement (not OEM). It is the extension cable that connects a Nellcor OxiSmart-compatible SpO2 sensor to the monitor's SpO2 input. The monitor end uses a 6-pin connector, and the sensor end accepts the sensor plug. The cable is 7.9 ft (2.4 m) long.
Compatible Monitor Models
This cable is compatible with Datascope monitors including the Passport XG, DPM1 through DPM5, MEC 100 and MEC 200, PM 600, PM 6000 (New), PM 9000 Express, VS 800, VS 900, 6201, and 809B. It is also compatible with Mindray Accutorr V, Duo, Trio, Passport V, MEC 1000, MEC 1200, and MEC 2000, PM 7000, PM 8000, and PM 9000, and VS-800 monitors, and with Nellcor SpO2-equipped versions of the Mindray DPM 3, DPM 4, DPM 5, PM 5000, and PM 6000. Select Edan, Kontron, Draeger, and other monitors are compatible as well, several of them only when equipped with the Nellcor SpO2 option. The complete model list, including which models require the Nellcor option, is in the Specifications tab.
Design and Construction
The adapter cable is designed for Nellcor OxiSmart sensor technology, so it should be paired with OxiSmart-compatible sensors. At 7.9 ft (2.4 m), the cable gives staff room to position the monitor away from the bedside while the sensor stays on the patient. It is reusable and ships one per bag.
When to Replace Your SpO2 Adapter Cable
Replace the adapter cable when the monitor shows sensor-off or no-sensor messages with a known-good sensor attached, or when SpO2 and pulse readings drop out or turn erratic as the cable is moved. Cracked or kinked jackets, bent or recessed pins at the monitor connector, and a loose or worn connector at the sensor end are also signs the cable should be retired. Testing with a known-good adapter cable is a quick way for biomedical staff to separate a cable fault from a sensor or monitor SpO2 board fault.
Cross Reference and Interchange Part Numbers
This cable interchanges with Mindray 0010-20-42594, 0010-30-43110, 512D-30-16752, and 040-001274-00, Edan M13-36091, 01.13.210001-13, 01.13.210001-14, and 01.13.036336-11, Draeger 2606487, Kontron MXC009, Unimed U708-29, and DRE P02796EXT. Contact IPR Medical with your monitor model or existing cable part number and we will confirm the match.
Why Source Mindray-Compatible SpO2 Cables from IPR Medical?
IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, so our team can help match SpO2 sensors and adapter cables to the monitors in your fleet. Our in-house technicians repair and refurbish monitoring equipment, and we keep compatible SpO2 cables and other monitoring accessories in stock to keep units in service. Browse more SpO2 sensors and adapter cables or contact us for help confirming the right part.
IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, including compatible SpO2 adapter cables. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Mindray, Philips, or any other manufacturer or supplier named on this page. Nellcor, Mindray, Philips, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.