IPR Medical

Philips M1940A Compatible SpO2 Adapter Cable, for Use with Philips FAST Sensors, 7.9 ft (2.4 m)

$70.00

The M1940A compatible SpO2 adapter cable (SKU SA-023-24) is a reusable aftermarket replacement (not OEM) with a 7.9 ft (2.4 m) cable, for use with the SpO2 sensor technology listed in the table below.

Cable Type SpO2 Adapter Cable
SpO2 Technology Philips FAST
Cable Length 7.9 ft (2.4 m)
Lifecycle Reusable
Packaging 1 per bag
Replaces Philips M1940A

Works with: the monitor models listed in the Specifications tab. Browse more SpO2 sensors and cables.

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems and SpO2 accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: SA-023-24 Categories: , Tags: ,
Send In Philips M1940A Compatible SpO2 Adapter Cable, for Use with Philips FAST Sensors, 7.9 ft (2.4 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SA-023-24
Replaces OEM Part Philips M1940A
Category Cables & Sensors > SpO2
Cable Type SpO2 Adapter Cable
SpO2 Technology Philips FAST
Used With Philips FAST sensors
Cable Length 7.9 ft (2.4 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Philips 78352A, 78352C, 78354A, 78354C, 78833A, 78833C, 78834A, 78834C, Agilent Series 50XM Fetal Monitor, Codemaster XL, HeartStart XL, M1020A, M1025A, M1025B, M1092A, M1094A, M1094B, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1275A, M1350, M1350B, M1351A, M1353A, M1722A, M1722A/B, M1722B, M1723A, M1723B, M1732A, M1732A/B, M1732B, M2475B, M3046A (M4 chip), Merlin, V24, V24E, Virida 50 IP, Viridia 24, Viridia 24C, Viridia A1, Viridia A3

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips M1940A, M1940B
AMC CB-A400-1006V
Beta Biomed B400-0600
Curbell 5566
Pacific Medical NXPH1940
Sage E08-22M
Tenacore TE1503
Unimed U708-40

IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and the patient monitors they support. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, HeartStart, Viridia, Codemaster, Merlin, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the M1940A Compatible SpO2 Adapter Cable?

The IPR Medical SA-023-24 is a compatible aftermarket (not OEM) SpO2 adapter cable that replaces OEM part M1940A. At 7.9 ft (2.4 m), this reusable adapter pairs with sensors of the technology identified in the Specifications table.


Compatible Monitor Models

Compatibility for OEM part M1940A spans dozens of listed models, all collected in the Compatible Monitor Models table on the Specifications tab. Because several model numbers carry letter suffixes or are listed in combined form, match the exact number on your equipment label to the table before ordering.


Design and Construction

Intended for use with the sensor technology shown in the Specifications table, the SA-023-24 is a reusable adapter with a 7.9 ft (2.4 m) cable, packaged one per bag. Clean it between patients according to facility protocol, and look it over for wear each time it is reconnected.


When to Replace Your SpO2 Adapter Cable

An adapter that is due for replacement usually shows physical wear first: cracks or cuts along the jacket, kinks that will not relax, a damaged connector body, bent pins, or a strain relief that is coming loose. On the monitor, watch for intermittent SpO2 values, repeated sensor alarms, and readings that shift when the cable is bumped. A quick swap to a known-good adapter, with the same sensor still attached, confirms whether the cable needs replacing.


Cross Reference and Interchange Part Numbers

Order this compatible adapter in place of OEM part M1940A; OEM number M1940B cross-references to it as well. Further down the Specifications tab, the Cross Reference / Interchange Part Numbers table sorts the matching aftermarket numbers by brand.


Why Source SpO2 Adapter Cables from IPR Medical?

Adapters like this one are part of what IPR Medical, an independent service organization with ISO 9001:2015 certification, buys, sells, repairs, and stocks for patient monitoring systems and infusion pumps. The repairs themselves are carried out in-house by IPR Medical technicians. Phone 855-477-8866, or look through our SpO2 sensors and cables for other accessories.

IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and the patient monitors they support. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, HeartStart, Viridia, Codemaster, Merlin, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews