Philips M1671A Compatible 3-Lead ECG Leadwire, Grabber/Pinch, AHA, Molded, 3.0 ft (0.9 m)
The M1671A compatible 3-lead ECG leadwire (SKU EL-PH3-90G-A) is a reusable aftermarket replacement (not OEM) with grabber/pinch electrode ends, AHA color coding, and a 3.0 ft (0.9 m) length for limb lead placement.
| Lead Count | 3-Lead |
| Lead Placement | Limb Lead |
| Electrode End | Grabber/Pinch |
| AHA/IEC Code | AHA |
| Lead Type | Philips IntelliVue |
| Cable Length | 3.0 ft (0.9 m) |
| Replaces | Philips M1671A |
Works with: the monitor models listed in the Specifications tab. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and ECG leadwires. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EL-PH3-90G-A |
| Replaces OEM Part | Philips M1671A |
| Category | Cables & Sensors > ECG/EKG |
| Product | ECG Leadwire |
| Lead Count | 3-Lead |
| Lead Placement | Limb Lead |
| Electrode End | Grabber/Pinch |
| AHA/IEC Code | AHA (RA white, LA black, LL red) |
| Distal Connector | Molded |
| Feature | Shielded |
| Lead Type | Philips IntelliVue |
| Cable Length | 3.0 ft (0.9 m) |
| Intended Use | Monitoring |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Bexen Cardio | Reanibex 700 |
| Biolight | M7000, M8500, M9500, Q Series |
| Invivo | 101, 360SL, 450SL, 521A, Escort 100, Escort 101, Escort 102, Escort 200, Escort 300, PortaPak 80, PortaPak 90, PortaPak 1000, Prism |
| Ivy Biomedical | 101, 7800, Cardiac Trigger Monitor 3150 |
| Newtech | NT3A |
| Nihon Kohden | BSM-8301A, BSM-8302A, BSM-8500A, BSM-8502A, NT3B, OEC-6102A (s/n>20156), OEC-6105A (s/n>20226), OEC-7102A, OEC-8108A, TEC-5200A (s/n>20421), TEC-7100A, TEC-7200A, TEC-7300A |
| PaceTech | MiniMax 4000CL, Minipack 300, Minipack 3000, Minipack 3100, Vitalmax 800 Plus, Vitalmax 2100, Vitalmax 2200, Vitalmax 4000, Vitalmax 4000 Modular, Vitalmax 4000CL, Vitalmax 4100, Vitalmax 4100CL |
| Philips | 43100A, 43110A, 43120A, 78352C, 78354C, 78834C, 862472, 862473, 862474, 862474 C3, 862475, 862478, 862479, 863064, 863065, 863066, 863068, 867036, Affiniti 30, Affiniti 50, Affiniti 70, Affiniti CVx, Agilent Series 50XM, C3, CX50, Envisor, EPIQ 7, HD15, HeartStart MRx, HeartStart XL, IE33, IntelliVue MP20, IntelliVue MP30, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MX500, IntelliVue MX750, IntelliVue MX800, IntelliVue MX850, M2, M3, M4, M1001A, M1001B, M1002A, M1002B, M1165A, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1264A, M1275A Transport, M1276A, M1280A, M1722A, M1722B, M1723A, M1723B, M2475B, M2601A, M3000A, M3001A, M3002A MMS X2, M3046A, M3535A, M3536A, M4735A, M8102A MP2, M8105A MP5, SureSigns VM6, SureSigns VM8, V24E, VM4 |
| Physio-Control | Lifepak 6, VSM-1ESF |
| Solaris | NT3C, NT3E, NT3F |
| Spacelabs | 400, 500, 600, 900, 90300, 90303B, 90308, 90408, 90425, 90428, 90431, 90432, 90470, 90600, 90700, 90701, 90721, 90724, PC Bedside, PCMS, TEK-208, TEK-408, TEK-413, TEK-414, TEK-511, TEK-512, TEK-514, TEK-5214045 |
| Welch Allyn | 242, Propaq Encore 206EL |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | M1671A, 989803145131, 453561490131, 453561490132, 453561490141, 989803133841, 989803145091, M1672A, M1675A |
| Authentic Medical | DLS-PHP3L-4F |
| Curbell | LDW-03BK-51AS-0000, LDW-03BK-29AS-0000 |
| Sage | L01-03-29P |
| Unimed | HP3-90P |
IPR Medical buys, sells, repairs, and stocks parts for ECG leadwires and the patient monitoring equipment they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, SureSigns, HeartStart, Affiniti, EPIQ, Envisor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the M1671A Compatible 3-Lead ECG Leadwire?
The IPR Medical EL-PH3-90G-A is a compatible aftermarket (not OEM) 3-lead ECG leadwire that replaces OEM part M1671A. Intended for ECG monitoring with limb lead placement, it has grabber/pinch electrode ends, AHA color coding, and a 3.0 ft (0.9 m) length, and it is reusable. The Specifications table shows its lead type.
Compatible Monitor Models
The compatibility list for this leadwire is extensive. It names select Nihon Kohden models such as the BSM-8302A, OEC-7102A, and TEC-7300A, select Spacelabs models including the 90303B, 90724, and PCMS, and select Physio-Control models, with the Lifepak 6 among them. Select Welch Allyn, Ivy Biomedical, PaceTech, Solaris, Biolight, Newtech, and Bexen Cardio models are included too. The full list is in the Compatible Monitor Models table on the Specifications tab, so please confirm your model there before ordering.
Design and Construction
Three limb leads, color coded to the AHA standard as RA white, LA black, and LL red, finish in grabber/pinch electrode ends. The leadwire is shielded, uses a molded distal connector, and is 3.0 ft (0.9 m) long. It is a reusable accessory that can be cleaned between patients per facility protocol, and it is packaged one per bag.
When to Replace Your 3-Lead ECG Leadwire
A grabber that has lost its grip, insulation that is nicked or cracked, and a connector with bent pins or a loose housing are all good reasons to replace the leadwire. Watch the monitor as well: persistent lead-off alerts, a noisy trace, or an ECG signal that drops out when the leadwire is flexed usually means it is near the end of its service life. Clinical engineering staff can confirm the fault by substituting a known-good leadwire.
Cross Reference and Interchange Part Numbers
In addition to OEM part M1671A, this compatible leadwire cross-references to OEM numbers 989803145131, 989803133841, 989803145091, 453561490131, 453561490132, and 453561490141. The rest of the interchange numbers are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source ECG Leadwires from IPR Medical?
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. We are an ISO 9001:2015-certified independent service organization, and our technicians perform monitor repairs in-house, which helps us recommend leadwires that suit the equipment you run. See more ECG cables and leadwires, or reach us at 855-477-8866 for ordering, repair, and parts support.
IPR Medical buys, sells, repairs, and stocks parts for ECG leadwires and the patient monitoring equipment they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, SureSigns, HeartStart, Affiniti, EPIQ, Envisor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.