IPR Medical

Philips M1355A Compatible TOCO Fetal Transducer, Reusable, 9.8 ft (3.0 m)

$315.00

The M1355A compatible TOCO fetal transducer (SKU FTC-PH01) is a reusable aftermarket replacement (not OEM) for uterine activity monitoring, with a 9.8 ft (3.0 m) cable length.

Transducer Type TOCO
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Packaging 1 set per box
Replaces Philips M1355A

Works with: the monitor models listed in the Specifications tab. Browse more fetal cables and transducers.

IPR Medical buys, sells, repairs, and stocks parts for fetal transducers and patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: FTC-PH01 Categories: , Tags: ,
Send In Philips M1355A Compatible TOCO Fetal Transducer, Reusable, 9.8 ft (3.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) FTC-PH01
Replaces OEM Part Philips M1355A
Category Cables & Sensors > Fetal
Product TOCO Fetal Transducer
Transducer Type TOCO
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Packaging 1 set per box

Compatible Monitor Models

Manufacturer Compatible Models
Philips M1350, M1350B, M1350C, M1351A, M1353A, M2922A, Series 50, Series 50 XM, Series 50 XMO, Series 50A

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips M1355A, 80320090, M1355-60011
Pacific Medical NTPH100
Tenacore TFCT-PH05-2303, TFHT102
Unimed UFT200-10

IPR Medical buys, sells, repairs, and stocks parts for TOCO transducers and other fetal monitoring accessories. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the M1355A Compatible TOCO Fetal Transducer?

The IPR Medical FTC-PH01 is a compatible aftermarket (not OEM) TOCO fetal transducer that replaces OEM part M1355A. A TOCO transducer is used for uterine activity monitoring. This one is reusable, has a 9.8 ft (3.0 m) cable length, and is packaged one set per box.


Compatible Monitor Models

Compatibility for the FTC-PH01 is documented entry by entry in the Compatible Monitor Models table on the Specifications tab. That table includes both series designations and individual model numbers, each exactly as listed for this part. Compare the model number on your monitor’s label with the table before you order, and our team can help if an entry is unclear.


Design and Construction

The FTC-PH01 is a TOCO-type transducer with a 9.8 ft (3.0 m) cable. It is intended for reuse, so it should be cleaned between patients as your facility’s protocol directs and inspected before it goes back into service. It ships one set per box.


When to Replace Your TOCO Fetal Transducer

Take the transducer out of service if its housing is cracked or chipped, if the cable jacket is cut, flattened, or kinked, or if the connector is damaged or sits loosely at the monitor. A uterine activity trace that drops out, stays flat, or shifts whenever the cable is moved is another common sign of a failing transducer. Checking with a known-good transducer on the same monitor helps confirm where the fault lies.


Cross Reference and Interchange Part Numbers

In addition to replacing OEM part M1355A, this compatible TOCO transducer cross-references to OEM number M1355-60011. Further interchange numbers, grouped by brand, are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.


Why Source TOCO Transducers from IPR Medical?

From patient monitors to infusion pumps, IPR Medical buys, sells, repairs, and stocks parts, and every repair and test is performed in-house by our own technicians. As an ISO 9001:2015-certified independent service organization, we help clinical and biomedical teams identify the right replacement transducer and keep their monitors ready for use. See more fetal cables and transducers, or reach our team at 855-477-8866.

IPR Medical buys, sells, repairs, and stocks parts for TOCO transducers and other fetal monitoring accessories. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.