GE Healthcare TS-E4-GE Compatible Adult Ear Clip SpO2 Sensor, TruSignal, Reusable, 9.8 ft (3.0 m)
The GE TruSignal ear sensor TS-E4-GE compatible replacement is a reusable, aftermarket adult ear clip SpO2 sensor (not OEM) for GE and Datex-Ohmeda monitors configured with TruSignal SpO2, built to OEM fit, form, and function.
| Sensor Type | Ear Clip |
| Patient Size | Adult / Pediatric |
| SpO2 Technology | GE TruSignal |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
Works with: TruSignal-equipped GE CARESCAPE B125/B450/B650/B850/V100, Dinamap B105/B125/B155M, ProCare B20/B40, Aisys and Aisys CS2, and Datex-Ohmeda S/5 monitors. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | SS-016-AE30 |
| OEM Reference | GE Healthcare TS-E4-GE |
| Sensor Type | Ear Clip |
| Patient Size | Adult / Pediatric |
| SpO2 Technology | GE TruSignal |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Monitor must be configured with GE TruSignal SpO2.
| Manufacturer / Series | Compatible Models |
| GE Healthcare CARESCAPE | B125, B450, B650, B850, V100 |
| GE Healthcare / Dinamap | B105M, B105P, B125M, B125P, B155M; ProCare B20, ProCare B40 |
| GE Healthcare Anesthesia | Aisys, Aisys CS2 |
| Datex-Ohmeda | S/5 (F-FM-00, F-FML-00); S/5 with E-series modules |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| GE Healthcare / Datex-Ohmeda | TS-E4-GE (OEM is 13 ft) |
| GE Healthcare / Datex-Ohmeda | TS-E2-GE (OEM is 7 ft) |
| Praymed | PSG0128-L |
| Unimed | U910-121 |
IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dinamap, ProCare, and Datex-Ohmeda patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, Nellcor, Masimo, or any other manufacturer or supplier named on this page. GE Healthcare, Nellcor, Masimo, OxiMax, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the GE TS-E4-GE Compatible Ear Clip SpO2 Sensor?
The GE Healthcare TS-E4-GE compatible SpO2 sensor is a reusable, aftermarket adult ear clip pulse oximetry sensor for GE and Datex-Ohmeda monitors configured with TruSignal SpO2. It is a direct-connect sensor with a 9.8 ft (3.0 m) integrated cable, so no separate interconnect cable is needed. It is a compatible replacement, not an original GE part, and it is built to OEM fit, form, and function.
Compatible Monitor Models
This compatible sensor is confirmed for use with TruSignal-equipped GE CARESCAPE B125, B450, B650, B850, and V100 monitors, Dinamap B105M, B105P, B125M, B125P, and B155M monitors, and GE ProCare B20 and B40 monitors. It also fits GE Aisys and Aisys CS2 anesthesia systems and Datex-Ohmeda S/5 monitors, including the F-FM-00 and F-FML-00 frames and S/5 systems with E-series modules. GE monitors have been offered with TruSignal, Masimo, or Nellcor SpO2, and each requires matching sensors, so confirm your monitor’s SpO2 configuration before ordering.
Design and Construction
The adult ear clip attaches to the earlobe, giving clinicians a monitoring site when fingers are unavailable or poorly perfused, such as during surgery, with peripheral vasoconstriction, or when the hands must remain free for procedures. The 9.8 ft (3.0 m) cable provides reach from the patient to a bedside, anesthesia, or pole-mounted monitor. The sensor is reusable after cleaning and disinfection according to facility protocol and ships one per bag.
When to Replace Your GE TruSignal Ear Clip Sensor
Replace the sensor when the monitor reports “SpO2 sensor off,” “no probe,” or sensor fault messages, when readings are erratic or the pleth waveform is weak with good sensor placement, or when the clip spring has weakened, the pads are worn or cracked, or the cable jacket is damaged near the clip or connector. Ear clip sensors are handled and repositioned often, so keeping spares on anesthesia carts and critical care units helps prevent monitoring gaps.
Cross Reference and Interchange Part Numbers
This compatible TruSignal adult ear clip SpO2 sensor, IPR Medical SKU SS-016-AE30, cross-references to GE Healthcare / Datex-Ohmeda part numbers TS-E4-GE and TS-E2-GE, and interchanges with Praymed PSG0128-L and Unimed U910-121. The OEM sensors come in different cable lengths, about 13 ft for TS-E4-GE and 7 ft for TS-E2-GE, so confirm the 9.8 ft (3.0 m) length suits your setup. For a TruSignal interconnect cable, see the compatible GE TS-G3, IPR Medical SKU SA-016-24TS.
Why Source SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible SpO2 sensors and cables for TruSignal, Masimo, Nellcor Oxismart, and Nellcor OxiMax configurations of GE monitors, so biomedical and anesthesia technology teams can supply mixed fleets from one source at lower cost than OEM. Our team can help identify each monitor’s SpO2 technology and support your GE equipment with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dinamap, ProCare, and Datex-Ohmeda patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, Nellcor, Masimo, or any other manufacturer or supplier named on this page. GE Healthcare, Nellcor, Masimo, OxiMax, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.