Mindray 650-206M Compatible IBP Adapter Cable for Utah Transducers, 12-Pin, 13 ft (4.0 m)

$62.50 Original price was: $62.50.$50.00Current price is: $50.00.

The Mindray 650-206M compatible IBP adapter cable (SKU IBP-MRA-UT40) is a reusable, aftermarket replacement (not OEM). It connects a disposable Utah-style pressure transducer to the 12-pin IBP input on a compatible Mindray, Datascope, or Edan monitor.

Cable Type IBP Adapter Cable, Reusable
Monitor End Round, Male 12-Pin, Keyed
Transducer End Utah Compatible
Cable Length 13 ft (4.0 m)
Jacket Gray, Latex-Free
Replaces Mindray 650-206M, 115-017849-00, AMC CB-91028, and more

Works with: select Mindray and Datascope Passport, DPM, BeneView, BeneVision N, ePM, iMEC, iPM, uMEC, cPM, BeneHeart, and VS models, plus select Edan monitors (see the Specifications tab for the exact compatible models). Browse more IBP cables and accessories.

IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: IBP-MRA-UT40 Categories: , Tags: ,
Send In Mindray 650-206M Compatible IBP Adapter Cable for Utah Transducers, 12-Pin, 13 ft (4.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) IBP-MRA-UT40
Replaces OEM Part Mindray 650-206M
Category IBP Adapter Cable
Monitor Connector Round, Male 12-Pin, Keyed
Transducer Connector Utah Compatible
Cable Length 13 ft (4.0 m)
Cable Jacket Gray, Latex-Free
Lifecycle Reusable
Packaging 1 per Bag

Compatible Equipment

For equipment with a 12-pin IBP input; used with Utah-style disposable pressure transducers.

Manufacturer Compatible Models
Mindray / Datascope BeneHeart D3, BeneHeart D6, BeneView T1, BeneView T5, BeneView T6, BeneView T7, BeneView T8, BeneView T9, BeneVision N1, BeneVision N12, BeneVision N12 Neo, BeneVision N15, BeneVision N15 Neo, BeneVision N15 OR, BeneVision N17, BeneVision N17 Neo, BeneVision N19, BeneVision N22, cPM 8, cPM 12, DPM 6, DPM 7, ePM 10, ePM 10 Neo, ePM 10M, ePM 12, ePM 12M, ePM 15, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM 6, iPM 8, iPM 10, iPM 12, iPM 12Vet, iPM-9800, Passport, Passport 8, Passport 12, Passport 12m, Passport 17m, uMEC7, uMEC10, uMEC12, uMEC15, uMEC15S, VS 9, VS 900
Edan Elite V5, Elite V6, Elite V8, iM8, iM8 Vet, iM8A, iM8B, iM9, iM9A, iM50, iM60, iM60 Vet, iM70, iM70 Vet, iM80, iM80 Vet, M3, M3A, M3B, M8, M8A, M8B, M9, M9A, M50, M80, X10, X12
Pronk Technologies SL-8

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Mindray 650-206M, 115-017849-00
Utah Medical 650-206M
AMC CB-91028, 10 ft (3.0 m)
Unimed BC-MR-UT

IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, including compatible IBP cables. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Utah Medical, Mindray, or any other manufacturer or supplier named on this page. Utah Medical, Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Mindray 650-206M Compatible IBP Adapter Cable?

The Mindray 650-206M compatible IBP adapter cable (SKU IBP-MRA-UT40) is a reusable, aftermarket replacement (not OEM) for the Mindray / Datascope 12-pin invasive blood pressure cable for Utah transducers. It connects a disposable Utah-style pressure transducer to the 12-pin IBP input on a compatible patient monitor, carrying the transducer signal for arterial, central venous, and other invasive pressure monitoring. The cable is 13 ft (4.0 m) long.


Compatible Equipment

This cable is compatible with Mindray and Datascope monitors that use the 12-pin IBP input, including the Passport, Passport 8, 12, 12m and 17m, DPM 6 and DPM 7, BeneView T1, T5, T6, T7, T8 and T9, BeneVision N1, N12, N15, N17, N19 and N22 (including the Neo and N15 OR versions listed), ePM 10, 10M, 12, 12M and 15, iMEC, iPM, uMEC, cPM 8 and 12, BeneHeart D3 and D6, and VS 9 and VS 900. It is also compatible with the Edan Elite V5, V6 and V8, the iM8, iM9, iM50, iM60, iM70 and iM80 families, the M3, M8, M9, M50 and M80 families, and the X10 and X12, as well as the Pronk Technologies SL-8. The full list is in the Specifications tab.


Design and Construction

The monitor end is a round, keyed, male 12-pin connector, and the patient end is a Utah-compatible transducer connector. Confirm that the monitor has a 12-pin IBP input before ordering. The gray cable jacket is latex-free, and the cable is reusable and ships one per bag.


When to Replace Your IBP Adapter Cable

Replace the cable when pressure waveforms show noise, drift, or dropouts that change when the cable is moved, when the monitor reports a transducer or IBP cable fault that clears with a known-good cable, or when zeroing becomes unstable. Cracked connector housings, bent or recessed pins, loose transducer latches, and cuts or kinks in the jacket are also reasons to retire the cable. Swapping in a known-good cable is a quick way for biomedical staff to separate a cable fault from a transducer or monitor IBP module fault.


Cross Reference and Interchange Part Numbers

This cable interchanges with Mindray 650-206M and 115-017849-00 and cross-references Utah Medical 650-206M, AMC CB-91028, and Unimed BC-MR-UT. The AMC CB-91028 is listed at 10 ft (3.0 m), so length differs from this 13 ft (4.0 m) cable.


Why Source Mindray-Compatible IBP Cables from IPR Medical?

IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, so our team can help match IBP cables and transducers to the monitors in your fleet. Our in-house technicians repair and refurbish monitoring equipment, and we keep compatible IBP cables and other monitoring accessories in stock to keep units in service. Browse more IBP cables and accessories or contact us for help confirming the right part.

IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, including compatible IBP cables. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Utah Medical, Mindray, or any other manufacturer or supplier named on this page. Utah Medical, Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.