Nihon Kohden BR-916PA Compatible 6-Lead ECG Leadwire, Snap, AHA, Molded, 3.0 ft (0.9 m)
The Nihon Kohden BR-916PA compatible 6-lead ECG leadwire (SKU EL-NKB6-90S-A) is a reusable aftermarket replacement (not OEM) with snap electrode ends, limb and chest lead placement, AHA color coding, and a 3.0 ft (0.9 m) length.
| Lead Count | 6-Lead |
| Lead Placement | Limb + Chest Lead |
| Electrode End | Snap |
| AHA/IEC Code | AHA |
| Cable Length | 3.0 ft (0.9 m) |
| Replaces | Nihon Kohden BR-916PA |
Works with: select Nihon Kohden BSM, Life Scope, PVM, and TEC models, plus select Skanray / Larsen & Toubro models. See the Specifications tab for the full list. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EL-NKB6-90S-A |
| Replaces OEM Part | Nihon Kohden BR-916PA |
| Category | Cables & Sensors > ECG/EKG |
| Product | ECG Leadwire |
| Lead Count | 6-Lead |
| Lead Placement | Limb + Chest Lead |
| Electrode End | Snap |
| AHA/IEC Code | AHA |
| Distal Connector | Molded |
| Feature | Shielded |
| Lead Type | Nihon Kohden (BR-9XXP) |
| Cable Length | 3.0 ft (0.9 m) |
| Intended Use | Monitoring |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Nihon Kohden | BSM-73, BSM-73C, BSM-230K, BSM-1101, BSM-1101K, BSM-1102, BSM-1102K, BSM-1700 Series, BSM-2000, BSM-2101, BSM-2102, BSM-2300, BSM-2300 Life Scope I, BSM-2300 Series, BSM-2300 with YJ 230P, BSM-2300C, BSM-2301, BSM-2301C, BSM-2303, BSM-2303C, BSM-2304, BSM-2351, BSM-2351C, BSM-2353, BSM-2353C, BSM-2354A, BSM-3000, BSM-3000 Series, BSM-3000 with AY 631P, BSM-3000 with AY 633P, BSM-3000 with AY 651P, BSM-3000 with AY 653P, BSM-3101, BSM-3500, BSM-3532, BSM-3552, BSM-3562, BSM-3700, BSM-3733, BSM-3753, BSM-3763, BSM-4100, BSM-4100 Life Scope P, BSM-4100 Series, BSM-4101, BSM-4101K, BSM-4102, BSM-4103, BSM-4103K, BSM-4104, BSM-4111, BSM-4111K, BSM-4112, BSM-4113, BSM-4113K, BSM-4114, BSM-5000 Series, BSM-5100, BSM-5100 Life Scope A, BSM-5100 Series, BSM-5100 with YJ 510P, BSM-5105, BSM-5105K, BSM-5135, BSM-5135K, BSM-6000 Series, BSM-6000 with AY 631P, BSM-6000 with AY 633P, BSM-6000 with AY 651P, BSM-6000 with AY 653P, BSM-6301, BSM-6301C, BSM-6301K, BSM-6311, BSM-6312, BSM-6312-NKFL/ZA, BSM-6313, BSM-6331, BSM-6332, BSM-6333, BSM-6501, BSM-6501C, BSM-6501K, BSM-6531, BSM-6532, BSM-6533, BSM-6571, BSM-6572, BSM-6573, BSM-6701, BSM-6701C, BSM-6701K, BSM-6731, BSM-6732, BSM-6733, BSM-6771, BSM-6772, BSM-6773, BSM-7100, BSM-7102A, BSM-7200, BSM-7201K, BSM-7211K, BSM-8200, BSM-8201, BSM-8300, BSM-8301, BSM-8301A, BSM-8302, BSM-8302A, BSM-8500, BSM-8500A, BSM-8502, BSM-8502A, BSM-8800, BSM-8800A, BSM-9100, BSM-9100 with AY 631P, BSM-9100 with AY 633P, BSM-9100 with AY 651P, BSM-9100 with AY 653P, BSM-9100 with YJ 671P, BSM-9101, BSM-9172, BSM-9173, BSM-9510, BSM-9510 Life Scope M, BSM-9510K, BSM-9800 Life Scope S, BSS 9800K, Life Scope 6700 Series, Life Scope LC BSM-3101K, Life Scope SVM 7200 Series, Life Scope TR, Lifescope G Series, Lifescope GZ-130, Lifescope GZ-140, Lifescope GZ-140P, NTX ZM-540/541P, PVM 2700, PVM 2703, PVM-2701, TEC 8300, Vismo PVM 2701, Vismo PVM 2703, ZM 920PG, ZM 930PG, ZM 940PG, ZM-520-PA, ZM-521-PA, ZM-530-PA, ZM-531-PA, ZM-900 Series Transmitters |
| Skanray / Larsen & Toubro | Galaxy, Planet 55, Star 50, Star 55 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Nihon Kohden | K915A, BR-916PA, BR-916P |
| AMC | LW-28100MX/6A |
| Curbell | LDW-06AF-29AN-0000 |
| Sage | L07-06-29S |
| Unimed | NKB6-90S |
IPR Medical buys, sells, repairs, and stocks parts for ECG leadwires for Nihon Kohden patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, or any other manufacturer or supplier named on this page. Nihon Kohden, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Nihon Kohden BR-916PA Compatible 6-Lead ECG Leadwire?
The IPR Medical EL-NKB6-90S-A is a compatible aftermarket (not OEM) 6-lead ECG leadwire that replaces the Nihon Kohden BR-916PA. It covers limb and chest lead placement with snap electrode ends, follows AHA color coding, and is 3.0 ft (0.9 m) long. This reusable leadwire is intended for ECG monitoring, and its lead type is listed as Nihon Kohden BR-9XXP.
Compatible Monitor Models
Monitors listed for this snap leadwire include select Nihon Kohden BSM models such as the BSM-2351, BSM-4100 Series, BSM-6701, and BSM-9510, plus select Life Scope, PVM, TEC, and ZM models, for example the Life Scope SVM 7200 Series and the ZM-900 Series Transmitters. Select Skanray / Larsen & Toubro models (Galaxy, Planet 55, Star 50, and Star 55) are included as well. Where a BSM entry is listed with a YJ or AY part number, the table reproduces that configuration as listed. Before ordering, confirm your monitor in the Compatible Monitor Models table on the Specifications tab.
Design and Construction
Six leads provide combined limb and chest placement, and each one ends in a snap that connects to a standard electrode stud. The leads use AHA color coding, the shielded leadwire has a molded distal connector, and it measures 3.0 ft (0.9 m). Being reusable, it can be cleaned between patients in line with facility protocol and kept in rotation while it continues to pass inspection. It ships one per bag.
When to Replace Your 6-Lead ECG Leadwire
Replace the leadwire when a snap feels loose or will not stay seated on the electrode, when the jacket on any lead is cracked, frayed, or kinked, or when the connector shows bent pins or other physical damage. Watch for chest or limb leads that drop out intermittently, persistent noise on one or more ECG leads, and lead-off alarms that come and go as the patient moves. Comparing against a known-good leadwire on the same monitor lets biomedical staff confirm whether the leadwire is at fault.
Cross Reference and Interchange Part Numbers
This compatible leadwire replaces the Nihon Kohden BR-916PA and cross-references to Nihon Kohden BR-916P and K915A. The Cross Reference / Interchange Part Numbers table on the Specifications tab lists the remaining interchange numbers.
Why Source ECG Leadwires from IPR Medical?
IPR Medical is an independent service organization certified to ISO 9001:2015. We buy, sell, repair, and stock parts for patient monitoring equipment and infusion pumps. Because our technicians handle monitor repair and testing in-house, we can help you select leadwires that suit your Nihon Kohden monitors and keep that equipment ready for use. Browse our ECG cables and leadwires, or call 855-477-8866 for assistance with orders, repairs, or parts.
IPR Medical buys, sells, repairs, and stocks parts for ECG leadwires for Nihon Kohden patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, or any other manufacturer or supplier named on this page. Nihon Kohden, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.