Masimo Compatible M-LNC-4 SpO2 Adapter Cable 2524, 4 ft (1.2 m), for M-LNCS Sensors
The IPR Medical SA-008RB-12ML is a compatible aftermarket replacement (not OEM) for the Masimo 2524 (M-LNC-4) SpO2 adapter cable. This reusable 4 ft (1.2 m) cable connects Masimo M-LNCS sensors to Masimo SET-equipped monitors and defibrillators.
| OEM Reference | Masimo 2524 (M-LNC-4) |
| Sensor Compatibility | Masimo M-LNCS Sensors |
| Monitor Connector | Masimo SET |
| Cable Length | 4 ft (1.2 m) |
Works with: Masimo Radical-7, Rad-8, Rad-5, Rad-57, Physio-Control LIFEPAK 12/15/20, Zoll E/M/R Series, and more. See all compatible SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Aftermarket Replacement (Non-OEM) |
| IPR Medical SKU | SA-008RB-12ML |
| OEM Reference | Masimo 2524 (M-LNC-4) |
| Cable Type | SpO2 Patient / Adapter Cable |
| Monitor Connector | Masimo SET |
| Sensor Compatibility | Masimo M-LNCS Sensors |
| Cable Length | 4 ft (1.2 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Device must have a Masimo SET SpO2 port and use M-LNCS sensors.
| Manufacturer | Compatible Models |
| Masimo Monitors | Radical, Radical-7, Rad-8, Rad-5, Rad-5v, Rad-9, Rad-87 |
| Masimo Handheld | Rad-57, Pronto-7 |
| Physio-Control | LIFEPAK 11, LIFEPAK 12, LIFEPAK 15, LIFEPAK 20, LIFEPAK 20e |
| Zoll | E Series, M Series, R Series |
| Welch Allyn | Propaq CS, Spot Vital Signs LXi, Spot Vital Signs 42MTB-E1, 45NE0-E1 LX, 53STP |
| Bitmos | SAT 800, SAT 801, SAT 805, SAT 816, satPuls, 901 M, 901 ML |
| GE Healthcare | Dinamap ProCare 300, ProCare Auscultatory 400, ProCare with Masimo Pro 1000, Pro 300V2, ProSeries V2, V300 |
| Mindray / Datascope | Accutorr V, Accutorr Plus, Duo, Trio, Passport 2, Passport 2LT, Passport V, Passport XG, Spectrum, Spectrum OR, EPM4, T8, V12, V21 (Masimo option models) |
| Philips (Invivo) | Escort II OPT30 Prism |
| Philips Respironics | Alice 5 |
| Other | Atom V-2100G, Comen C60 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2524 (M-LNC-4) |
| Draeger | MP02988 |
| IPR Medical | SA-008RB-12ML |
IPR Medical buys, sells, repairs, and stocks parts for Masimo SET pulse oximetry equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Masimo Compatible M-LNC-4 SpO2 Adapter Cable 2524?
The IPR Medical SA-008RB-12ML is a compatible aftermarket replacement for the Masimo 2524 (M-LNC-4) SpO2 adapter cable. It is not an OEM product. This 4 ft (1.2 m) reusable patient cable connects Masimo M-LNCS series pulse oximetry sensors to monitors and defibrillators equipped with Masimo SET technology. It is designed to match the original 2524 cable in fit, form, and function.
Compatible Monitor Models
This cable is compatible with Masimo Radical, Radical-7, Rad-8, Rad-5, Rad-5v, Rad-9, and Rad-87 monitors, and with the Rad-57 and Pronto-7 handhelds. On the defibrillator side, it supports the Physio-Control LIFEPAK 11, 12, 15, 20, and 20e and the Zoll E Series, M Series, and R Series. It also fits Masimo-equipped Welch Allyn Propaq CS and Spot Vital Signs monitors, Bitmos SAT 800-series and 901 units, and GE Dinamap ProCare and ProSeries monitors. Mindray/Datascope Accutorr, Duo, Trio, Passport, and Spectrum monitors with the Masimo option, the Philips Invivo Escort II, and the Philips Respironics Alice 5 are also supported. Please confirm that your device has a Masimo SET SpO2 port and uses M-LNCS sensors before ordering.
Design and Construction
The cable has a Masimo SET connector on the monitor end and an M-LNCS sensor connector on the patient end, joined by a flexible, shielded 4 ft (1.2 m) cable. The M-LNCS interface is a different connector from the standard LNCS interface. This cable will not accept standard LNCS, LNOP, or RD series sensors. The shorter length keeps the cable run tidy at bedside, on transport monitors, and on defibrillators, where extra cable can tangle or snag. The cable is reusable and supplied one per bag.
When to Replace Your M-LNC-4 SpO2 Adapter Cable
Replace the cable if you see any of the following: intermittent or dropped SpO2 readings, “sensor off” or “no cable” alarms when a known-good sensor is attached, cracked or loose connector housings, bent or recessed pins, or a cut or kinked jacket. Biomedical technicians can confirm a cable fault by swapping in a known-good cable and sensor. If readings return to normal, the cable should be retired. Keeping a spare M-LNC-4 cable on hand reduces monitor downtime on crash carts, in transport, and in procedural areas.
Cross Reference and Interchange Part Numbers
The IPR Medical SA-008RB-12ML cross-references to Masimo 2524 (M-LNC-4) and Draeger MP02988. This cable is for M-LNCS sensors only. If your facility uses standard LNCS sensors on a gray Masimo SET port, choose the compatible LNC-4 cable, IPR Medical SKU SA-008RB-12LS. If your device has a red Masimo rainbow SET connector and uses M-LNCS sensors, choose the compatible RC-4 cable, IPR Medical SKU SA-009RB-12ML.
Why Source SpO2 Adapter Cables from IPR Medical?
IPR Medical is an ISO 9001:2015 certified supplier of patient monitoring accessories, infusion pump parts, and medical equipment. Our team works with biomedical departments, materials managers, and clinical staff every day to find the right compatible cables and sensors quickly and at a fraction of OEM cost. Beyond accessories, IPR Medical buys, sells, and repairs patient monitoring equipment in-house, and stocks a deep inventory of replacement parts.
IPR Medical buys, sells, repairs, and stocks parts for Masimo SET pulse oximetry equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.


















