Draeger 3368391 Compatible MultiMed 5 Multi-Parameter Cable, 5-Lead ECG, Dual 7-Pin Aux Ports, 8.2 ft (2.5 m), AHA/IEC
The Draeger 3368391 compatible multi-parameter cable (SKU ETM-SM-E5ST) is a reusable, aftermarket replacement (not OEM) for the Draeger MultiMed 5 cable that combines a 5-lead ECG trunk with dual auxiliary connectors on a single cable, built to match the original’s fit, form, and function.
| Cable Type | Multi-Parameter ECG Trunk Cable (Long Trunk) |
| Lead Count | 5 Leads (Supports 3-Lead Configuration) |
| Color Code | AHA/IEC |
| Cable Length | 8.2 ft (2.5 m) |
| Patient Size | Adult/Pediatric |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
| Replaces | Draeger 3368391, 5950192 |
Works with: select Draeger Infinity monitors, including the Delta, Gamma, Kappa, Vista, Omega S, C500, and C700, and the Draeger SC 6000, SC 7000, and SC 9000. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | ETM-SM-E5ST |
| OEM Reference | Draeger 3368391 (MultiMed 5 Cable) |
| Cable Type | Multi-Parameter ECG Trunk Cable (Long Trunk) |
| Lead Count | 5 Leads (Supports 3-Lead Configuration) |
| Lead Placement | Limb + Chest |
| Color Code | AHA/IEC |
| ECG Leadwire Connector | Twin-Pin, Molded DIN-Style |
| Auxiliary Connectors | Dual Round 7-Pin |
| Cable Length | 8.2 ft (2.5 m) |
| In-Line Resistance | 1K Ohms |
| Cable Jacket | TPU, Gray |
| Patient Size | Adult/Pediatric |
| Lifecycle | Reusable |
| Latex-Free | Yes |
| Sterile | No |
| Packaging | 1 per Bag |
| Weight | 0.6 lbs (279 g) |
Compatible Monitor Models
| Manufacturer | Compatible Model |
| Draeger | Infinity C500 |
| Draeger | Infinity C700 |
| Draeger | Infinity Delta |
| Draeger | Infinity Delta XL |
| Draeger | Infinity Gamma |
| Draeger | Infinity Gamma X |
| Draeger | Infinity Gamma XL |
| Draeger | Infinity Kappa |
| Draeger | Infinity Kappa XLT |
| Draeger | Infinity Omega S |
| Draeger | Infinity Vista |
| Draeger | Infinity Vista XL |
| Draeger | SC 6000 |
| Draeger | SC 7000 |
| Draeger | SC 9000 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Draeger | 3368391 |
| Draeger | 5950192 |
| Argo Biomedical | ARETM-SM-E5ST |
| Diagramm | 852220 |
| MAC | SMM-STE5 |
| Sage Services Group | T09-25M |
| Unimed | SM-STE5 |
| Aftermarket Equivalent | TM-STE50 |
| Aftermarket Equivalent | NESM6253 |
IPR Medical buys, sells, repairs, and stocks parts for the Draeger Infinity Delta, Infinity Vista, Infinity Kappa, and SC series monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, or any other manufacturer or supplier named on this page. Draeger, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Draeger 3368391 Compatible Multi-Parameter Cable?
The Draeger 3368391 compatible multi-parameter cable is a reusable, aftermarket replacement for the Draeger MultiMed 5 cable. It is a long-trunk cable that brings several patient connections into one line back to the monitor. Instead of running separate cables for each parameter, the MultiMed 5 design combines a 5-lead ECG trunk with two auxiliary 7-pin inputs, which keeps the bedside tidier and makes transport and setup faster. It is a compatible replacement, not an original Draeger part, and it is built to the same fit, form, and function as the OEM 3368391 cable.
Compatible Monitor Models
This compatible cable is confirmed for use across the Draeger Infinity monitor family, including the Infinity Delta, Delta XL, Gamma, Gamma X, Gamma XL, Kappa, Kappa XLT, Vista, Vista XL, and Omega S, as well as the Infinity C500 and C700 workstations. It also fits the SC 6000, SC 7000, and SC 9000 monitors. Because these platforms share the MultiMed connection, a single cable type can serve a mixed fleet of older and newer Draeger monitors. That simplifies stocking for biomedical and materials management teams.
Design and Construction
The cable runs 8.2 ft (2.5 m), which gives the long-trunk reach needed to route from the monitor to the patient at the bedside or on a transport stretcher. At the patient end, a molded DIN-style twin-pin ECG connection accepts 5-lead limb-and-chest leadwire sets and also supports 3-lead monitoring, with AHA/IEC labeling. Two round 7-pin auxiliary connectors let compatible parameter adapters plug into the same trunk. A 1K ohm in-line resistance is built into the signal path. The gray TPU jacket is durable, flexible, and holds up to routine hospital cleaning. The cable is latex-free, non-sterile, rated for adult and pediatric patients, weighs about 0.6 lbs (279 g), and ships one per bag.
When to Replace Your Draeger MultiMed Cable
Because a MultiMed cable carries several parameters at once, one failure can take down more than ECG monitoring. Replace the cable when every ECG lead shows noise or dropout at once, when an auxiliary parameter drops out even with a known-good sensor or adapter, when readings go intermittent as the cable is moved, or when you find bent or recessed connector pins, a cracked molded housing, a split or kinked jacket, or a connector that no longer locks securely. Swapping in known-good leadwires and adapters first is a quick way to confirm that the trunk cable is at fault before replacing it.
Cross Reference and Interchange Part Numbers
This compatible multi-parameter cable, IPR Medical SKU ETM-SM-E5ST, cross-references to Draeger part numbers 3368391 and 5950192. It also interchanges with Argo Biomedical ARETM-SM-E5ST, Diagramm 852220, MAC SMM-STE5, Sage Services Group T09-25M, and Unimed SM-STE5, as well as aftermarket equivalents TM-STE50 and NESM6253. Materials managers and purchasing staff can use any of these numbers to confirm the match against existing inventory, work orders, or requisitions. Contact IPR Medical if you are replacing a part number not listed here and need help confirming compatibility.
Why Source MultiMed Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. Our compatible cables and sensors give biomedical departments an affordable alternative to OEM accessories while matching OEM fit and function. This matters most for multi-parameter cables like the MultiMed 5, where OEM replacement cost is high and legacy Infinity and SC series fleets remain in wide use. Our team can help confirm the right cable and leadwire combination, source hard-to-find accessories, and support your monitors with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for the Draeger Infinity Delta, Infinity Vista, Infinity Kappa, and SC series monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, or any other manufacturer or supplier named on this page. Draeger, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.