Draeger/Siemens 5592162 Compatible 3-Lead ECG Adapter Cable with Respiration, Round 7-Pin to Safety DIN, for NeoMed Pod, 8.2 ft (2.5 m), AHA
The Draeger/Siemens 5592162 compatible 3-lead ECG adapter cable (SKU ET-3027-D-A) is a reusable, aftermarket replacement (not OEM) for the ECG cable that plugs into the Draeger NeoMed Pod and other Draeger/Siemens round 7-pin ECG inputs. It has a round 7-pin pod connector, an 8.2 ft (2.5 m) cable, and a 3-lead AHA yoke that accepts Safety DIN leadwires, and it carries both ECG and impedance respiratory rate signals.
| Cable Type | 3-Lead ECG Adapter Cable with Respiration |
| Connects To | Draeger NeoMed Pod and Round 7-Pin Draeger/Siemens ECG Inputs |
| Leadwire End | 3-Lead Yoke, Safety DIN, AHA |
| Cable Length | 8.2 ft (2.5 m); OEM is 4.9 ft (1.5 m) |
| Patient Size | All Sizes (Standard 3-Lead Safety DIN Yoke) |
| Construction | TPU, Reusable, Latex-Free |
Works with: the Draeger NeoMed Pod on Infinity Delta, Delta XL, Kappa, and Vista monitors and on Siemens/Draeger SC 5000 through SC 9000XL monitors. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for Draeger and Siemens patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | ET-3027-D-A |
| OEM Reference | Siemens/Draeger 5592162 (OEM is 1.5 m) |
| Cable Type | 3-Lead ECG Adapter Cable (NeoMed Pod) |
| Lead Count | 3 Leads |
| Parameters | ECG + Impedance Respiratory Rate |
| Color Code | AHA (US): RA White, LA Black, LL Red |
| Monitor-End Connector | Round 7-Pin Draeger/Siemens (NeoMed Pod ECG Socket and Matching 7-Pin Inputs) |
| Leadwire-End Connector | 3-Lead Yoke, Accepts Safety DIN Leadwires |
| Cable Length | 8.2 ft (2.5 m); OEM 5592162 is 4.9 ft (1.5 m) |
| Cable Jacket | TPU |
| Patient Size | Adult / Pediatric / Neonatal (Standard 3-Lead Safety DIN Yoke) |
| Lifecycle | Reusable |
| Latex-Free | Yes |
| Sterile | No |
| Packaging | 1 per Bag |
| Weight | 0.4 lbs |
Compatible Monitor Models
Connects to the NeoMed Pod ECG socket; the monitors below use the pod or a matching round 7-pin ECG input.
| Manufacturer | Compatible Model |
| Draeger | Infinity Delta |
| Draeger | Infinity Delta XL |
| Draeger | Infinity Kappa |
| Draeger | Infinity Vista |
| Draeger | NeoMed Pod |
| Draeger / Siemens | SC 5000 |
| Draeger / Siemens | SC 6000 |
| Draeger / Siemens | SC 7000 |
| Draeger / Siemens | SC 8000 |
| Draeger / Siemens | SC 9000 |
| Draeger / Siemens | SC 9000XL |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Siemens | 5592162 |
| Unimed | D-1323 |
IPR Medical buys, sells, repairs, and stocks parts for the Draeger Infinity Delta, Infinity Vista, and SC series monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, Siemens, or any other manufacturer or supplier named on this page. Draeger, Siemens, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Draeger/Siemens 5592162 Compatible NeoMed Pod ECG Cable?
The Draeger/Siemens 5592162 compatible 3-lead ECG adapter cable (IPR SKU ET-3027-D-A) connects a 3-lead set of Safety DIN leadwires to the round 7-pin ECG socket on the Draeger NeoMed Pod and to other Draeger/Siemens equipment that uses the same round 7-pin ECG input. It is a compatible aftermarket replacement, not an original Draeger or Siemens part, built to match the connector, lead configuration, and function of the OEM 5592162 adapter cable. The NeoMed Pod is the neonatal multiparameter pod used with Draeger Infinity and Siemens SC series monitors, and this cable supplies its ECG input. Because the patient end is a standard 3-lead Safety DIN yoke, the cable is not limited to neonatal leads; it accepts adult, pediatric, and neonatal Safety DIN leadwire sets. Along with the ECG signal, the cable carries the thoracic impedance signal the monitor uses to calculate respiratory rate, so one cable and electrode set provide both parameters at the bedside.
Compatible Monitor Models
This compatible adapter cable plugs into the Draeger NeoMed Pod. Through the pod it works with the Draeger Infinity Delta, Infinity Delta XL, Infinity Kappa, and Infinity Vista monitors, and with the SC 5000, SC 6000, SC 7000, SC 8000, SC 9000, and SC 9000XL monitors, which were first sold under the Siemens name and later supported by Draeger. On these monitors the NeoMed Pod provides the round 7-pin ECG socket; the cable also fits other Draeger and Siemens equipment with the same round 7-pin ECG input. Respiratory rate display depends on the monitor configuration, so biomedical technicians should confirm that respiration monitoring is enabled on the unit if that parameter is needed.
Design and Construction
The cable runs 8.2 ft (2.5 m) from the pod to the patient yoke, which gives more reach than the OEM cable in incubator, warmer, and bedside layouts where the pod sits away from the patient. The pod end has a round 7-pin connector keyed to the NeoMed Pod ECG socket. The patient end has a 3-lead yoke with Safety DIN (touch-proof) receptacles, labeled with the AHA color code used in US facilities: white for right arm, black for left arm, and red for left leg. The yoke accepts standard 3-lead Safety DIN leadwires in snap or grabber style and in adult, pediatric, or neonatal sizes, so each facility can choose the electrode attachment it prefers and replace worn leadwires without replacing the whole cable. The TPU jacket is durable, flexible, and holds up to routine cleaning. The cable is latex-free, non-sterile, and ships one per bag.
When to Replace Your NeoMed Pod ECG Cable
Adapter cables take constant strain at the pod connector and the yoke from incubator access, bed movement, patient repositioning, and cable management. Replace the cable when every lead shows noise or dropout at once (a sign the problem is upstream of the leadwires), when respiratory rate readings become erratic while the ECG looks normal, or when you find bent or recessed connector pins, a cracked yoke, a split jacket, or a connector that no longer seats securely in the pod. Swapping in a known-good leadwire set first is a quick way to confirm whether the adapter cable or the leads are at fault.
Cross Reference and Interchange Part Numbers
This compatible 3-lead ECG adapter cable with respiration, IPR Medical SKU ET-3027-D-A, cross-references to Siemens/Draeger part number 5592162 and Unimed part number D-1323. The OEM 5592162 is a 4.9 ft (1.5 m) cable; this compatible version is 8.2 ft (2.5 m) with the same connectors and lead configuration. This cable takes Safety DIN leadwires, not the single-pin lead sets used with the Infinity M540 and MultiMed Plus, and it is not a replacement for the NeoMed Pod itself (Draeger 5590539). Contact IPR Medical if you are replacing a part number not listed here and need help confirming compatibility.
Why Source Draeger-Compatible ECG Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. Our compatible cables and sensors give biomedical departments an affordable alternative to OEM accessories while matching OEM fit and function. This matters most for legacy Draeger and Siemens fleets such as the Infinity Delta and SC series, where OEM accessories can be hard to find. Our team can help confirm the right pod, adapter cable, and leadwire combination, source hard-to-find accessories, and support your monitors with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for the Draeger Infinity Delta, Infinity Vista, SC series monitors, and NeoMed Pod. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, Siemens, or any other manufacturer or supplier named on this page. Draeger, Siemens, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.