Philips Avalon Toco+ MP Fetal Transducer (M2735A) | DECG/MECG/IUP
The Philips Avalon Toco+ MP Transducer (M2735A) is the most versatile wired Smart Transducer in the Avalon family — it measures uterine activity via external Toco, captures maternal pulse with built-in Smart Pulse, and accepts adapter cables for direct fetal ECG (DECG), maternal ECG (MECG), or intrauterine pressure (IUP). One transducer covers four measurement modes, which is why labor and delivery floors keep the M2735A on hand even when most patients are monitored externally.
The Toco+ MP connects to any of the four fetal sensor sockets on Avalon FM20, FM30, FM40, or FM50 monitors via a standard D-shaped connector. Smart Pulse is always active when the transducer is applied, feeding maternal pulse into the monitor’s Cross-Channel Verification (CCV) feature to reduce the risk of mistaking maternal pulse for fetal heart rate. When DECG, MECG, or IUP monitoring is needed, the user simply plugs the appropriate adapter cable into the transducer’s auxiliary connector — the monitor automatically detects the mode.
| OEM Part Number | M2735A (989803143681) |
| Measurements | Toco, Smart Pulse, DECG, MECG, IUP |
| Compatible Monitors | Avalon FM20, FM30, FM40, FM50 |
| Connector | D-shaped (plug-and-play to any fetal sensor socket) |
| Auxiliary Connector | 7-pin D-type for DECG/MECG/IUP adapter cables |
| Smart Pulse | Built-in, no separate SpO2 or MECG sensor required |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact us at 855-477-8866 or cs@iprmed.com.
Also available from IPR Medical:
Philips M2734A / M2734B Smart Toco MP Transducer — wired external Toco with Smart Pulse |
Philips Avalon Ultrasound Fetal Transducer (M2736A) — wired US transducer for external FHR |
Philips Avalon CL Wireless Toco+ MP (866075) — cableless equivalent |
Philips Avalon CL Wireless ECG/IUP (866077) — cableless DECG/MECG/IUP |
Philips Avalon FM50 Fetal Monitor — host monitor
Philips Avalon Toco+ MP Transducer (M2735A) — Specifications
| Manufacturer | Philips Healthcare |
| Model / OEM Part Number | M2735A (Philips catalog 989803143681) |
| Device Type | Wired Smart Toco+ Transducer with auxiliary DECG/MECG/IUP capability |
| Intended Use | External monitoring of uterine activity and maternal pulse, with optional internal monitoring of DECG, MECG, or IUP via adapter cables, on Avalon FM series fetal monitors |
| Patient Population | Antepartum and intrapartum patients |
| Measurements Supported | External Toco (uterine activity), Smart Pulse (maternal pulse), DECG (fetal scalp ECG), MECG (maternal ECG), IUP (intrauterine pressure) |
| Toco Sensor Element | Pressure-sensitive strain gauge resistor bridge with DC excitation |
| Smart Pulse Technology | Two integrated infrared sensors continuously measure maternal pulse; active automatically when transducer is applied |
| ECG System | 3-lead (RA, LA, reference); supports DECG and MECG; auto-detects mode via adapter cable |
| IUP System | Piezoresistive bridge with AC excitation; compatible with Koala-type disposable sensor-tip IUP catheters via M1334A adapter cable |
| Primary Connector | D-shaped, plug-and-play to any of the four fetal sensor sockets on Avalon FM20/FM30/FM40/FM50 |
| Auxiliary Connector | 7-pin D-type socket for DECG, MECG, or IUP adapter cables; external mode resistor sets measurement mode automatically |
| Compatible Fetal Monitors | Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) |
| Transducer Finder LED | Active; illuminates when the corresponding measurement is selected on the monitor |
| Belt Attachment | Integrated belt button; compatible with Avalon butterfly belt clip for belts without button holes |
| Latex Content | Latex-free |
| Operating Temperature | 32 °F to 104 °F |
| Operating Humidity | Up to 95% relative humidity at 104 °F (non-condensing) |
| Operating Altitude | −1640 ft to 9840 ft |
| Storage / Transport Temperature | −4 °F to 140 °F |
| Storage / Transport Humidity | Up to 90% relative humidity at 140 °F (non-condensing) |
| Storage / Transport Altitude | −1640 ft to 43,000 ft |
| Software Requirements | Smart Pulse functionality requires Avalon fetal monitor software revision J.3x.xx or later. See the Description Tab for software platform detail. |
| FDA Regulatory Pathway | Marketed as an accessory under the Avalon fetal monitor 510(k) clearances; most recent parent clearance K140535 (Avalon FM20/FM30/FM40/FM50), product code HGM, 21 CFR 884.2740, Class II |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
Overview
The Philips Avalon Toco+ MP Transducer (M2735A) is the most capable wired Smart Transducer in the Avalon family. It combines four measurement modes — external Toco for uterine activity, Smart Pulse for maternal pulse, fetal scalp ECG (DECG), maternal ECG (MECG), and intrauterine pressure (IUP) — into a single transducer body. The “+” in the name refers to the auxiliary 7-pin D-type connector on the transducer housing, which accepts a DECG, MECG, or IUP adapter cable. The “MP” suffix refers to the integrated Smart Pulse feature, which uses two built-in infrared sensors to measure maternal pulse continuously whenever the transducer is in contact with the patient’s abdomen. Smart Pulse is patent-protected by Philips and runs automatically without any additional SpO2 sensor, ECG electrodes, or operator input. The M2735A is plug-and-play with any Avalon FM20, FM30, FM40, or FM50 fetal monitor via the standard D-shaped Smart Transducer connector, and it shares the same digital signal processing architecture as the rest of the Avalon Smart Transducer family. Each transducer contains its own CPU and signal-processing board, so adding the M2735A to a monitor does not place an additional processing burden on the host — the transducer delivers its measurement result as a digital data stream.
Toco Measurement and Smart Pulse
External Toco measurement is performed by a pressure-sensitive strain gauge resistor bridge inside the transducer housing. The strain gauge requires a DC excitation voltage, and its differential output is proportional to the pressure applied to the transducer surface as the maternal abdomen hardens during a contraction. The signal is digitized by an A/D converter inside the transducer and sent to the monitor as processed data. Smart Pulse, the “MP” function, runs in parallel: two built-in optical sensors emit low-power infrared light comparable to a TV remote and detect the reflected signal from the maternal abdomen, allowing the transducer to derive maternal pulse without electrodes, cables, or a SpO2 sensor. When the M2735A is applied, Smart Pulse becomes available a few seconds after contact is established. Maternal pulse is then continuously compared against any fetal heart rate channels on the monitor via Cross-Channel Verification (CCV), which alerts the clinician when a fetal channel and the maternal channel begin tracking the same rhythm — the classic signal-ambiguity scenario where the maternal pulse is mistaken for fetal heart rate.
DECG, MECG, and IUP via Adapter Cables
The auxiliary 7-pin D-type socket on the M2735A accepts one of three Philips adapter cables, each of which automatically configures the transducer for the corresponding measurement mode. The M1362B DECG Reusable Legplate Adapter Cable connects to a Philips fetal scalp electrode (such as the 15133E Qwik Connect Plus Spiral Electrode) via an M1349A attachment electrode, and the transducer captures the fetal cardiac signal directly from the presenting part. The M1363A MECG Adapter Cable connects to two pre-gelled foam electrodes applied to the mother for maternal ECG capture, useful for high-acuity cases where direct rhythm monitoring is needed alongside obstetric trending. The M1334A Adapter Cable TTIUP connects to a Koala-style disposable sensor-tip intrauterine pressure catheter for direct uterine pressure measurement, used in labor management cases where external Toco does not provide adequate pressure resolution. Mode detection is automatic — an external mode resistor inside each adapter cable identifies itself to the transducer’s frontend so the user does not need to navigate menus to switch between modes. The ECG frontend is a 3-lead system (RA, LA, and reference) with ESD-protected inputs and a 16-bit A/D converter shared with the IUP channel.
Software Versions and Platform Evolution
The M2735A Toco+ MP Transducer requires the appropriate Avalon FM-series monitor software to expose its full measurement set. Avalon fetal monitor software has evolved through several major releases — early Avalon platforms shipped with software revisions in the F, G, and H families, which supported the original Toco transducer (M2734A) and the Toco+ transducer (M2735A) for DECG, MECG, and IUP but did not yet expose Smart Pulse functionality. Smart Pulse was introduced with the J-series software releases. Specifically, the integration of Smart Pulse into the Toco MP and Toco+ MP transducers requires Avalon fetal monitor software revision J.3x.xx or later, sometimes referred to as “Rel. J.3” in Philips application notes. From J.3 onward, the monitor exposes Smart Pulse maternal pulse as a separate numeric and trace channel and uses it as a CCV input alongside any active fetal channels. The DECG/MECG/IUP capabilities of the M2735A continued to work on earlier software but without the maternal pulse cross-check that Smart Pulse provides. Hospitals running pre-J.3 Avalon software may need a service upgrade before deploying the M2735A in its full Toco+ MP configuration. IPR Medical can confirm the software revision installed on a monitor at the time of refurbishment and advise on upgrade paths through Philips authorized service.
Clinical Workflow and Belt Attachment
The Toco+ MP attaches to the patient with a standard Avalon abdominal belt; the integrated belt button on the transducer housing accepts buttonhole belts directly, and for belts without buttonholes a butterfly belt clip is supplied with the system. The transducer should be applied without gel or water between the skin and the transducer surface, because conductive media can compromise the Toco baseline and interfere with Smart Pulse infrared reception. When the transducer is applied, Smart Pulse activation is automatic — no operator action is required. Each transducer features a Finder LED on its housing; when the clinician touches the corresponding FHR or maternal numeric on the monitor’s touchscreen, the LED on the matching transducer illuminates, eliminating ambiguity over which transducer is producing which trace. This is particularly useful in twin and triplet monitoring scenarios where multiple US and Toco transducers are in use simultaneously. The M2735A is rated for use on the maternal abdomen in routine antepartum surveillance and intrapartum labor monitoring, and the auxiliary connector remains accessible while the transducer is belted in place, so DECG, MECG, or IUP can be initiated mid-labor without removing the Toco transducer.
Trending, Cross-Channel Verification, and Clinical Decision Support
All measurements from the M2735A — Toco, Smart Pulse, DECG, MECG, and IUP — are presented on the Avalon monitor display as numerics and waveform traces and are recorded to the integrated fetal recorder paper trace. The host monitor’s Cross-Channel Verification (CCV) function continuously compares every fetal channel against every maternal channel and posts an on-screen indicator when two channels begin tracking the same rate, helping the clinician identify maternal-for-fetal confusion before it affects clinical decision-making. When Smart Pulse is the source of the maternal pulse rate, the monitor does not produce an audible QRS tone and certain alarm behaviors are suppressed per Philips’ Instructions for Use, because Smart Pulse is intended as a coincidence-detection input rather than a primary alarm source. The recorder offset, paper scale, and recorder speed settings are managed by the host monitor, not by the transducer itself. Data captured during a monitoring session can be exported to Philips OB TraceVue or IntelliSpace Perinatal (ISP) over the monitor’s LAN connection, where it becomes part of the patient’s electronic obstetric record.
Network and EMR Integration
The Toco+ MP itself does not have a network interface — all connectivity is handled by the host Avalon FM-series monitor. On the FM20 and FM30, integration with OB TraceVue or IntelliSpace Perinatal is available over RS232 or LAN; the FM40 and FM50 add additional LAN capabilities and, on FM50, a VGA output for an external display. Once the transducer is connected to a network-enabled Avalon monitor, all M2735A measurement data flows through the monitor’s clinical data interface to the perinatal information system. There is no separate firmware on the transducer that requires hospital network access — the transducer’s onboard CPU stores calibration, country-specific configuration, and error logs in a serial EEPROM, and the monitor reads this data over the D-shaped Smart Transducer connector at plug-in. From a clinical engineering perspective, this means software and configuration changes affecting M2735A behavior live on the host monitor, not on the transducer, so transducer swaps are truly plug-and-play and do not require post-installation configuration.
IPR Medical — Buy, Sell, Repair, and Parts
IPR Medical buys, sells, and repairs the Philips Avalon Toco+ MP Transducer (M2735A) and stocks the OEM and OEM-equivalent parts needed to keep it in service. Common repair scenarios on the M2735A include cable damage at the strain-relief boot, intermittent contact at the D-shaped main connector, and damage to the 7-pin auxiliary D-type socket caused by side loading from adapter cables. IPR Medical can quote a full functional refurbishment that includes connector inspection, cable replacement where required, full Toco/Smart Pulse/DECG/MECG/IUP functional testing per Philips service manual procedures, and electrical safety testing. IPR Medical also stocks compatible Avalon abdominal belts, butterfly belt clips, M1362B DECG legplate adapter cables, M1363A MECG adapter cables, M1334A IUP adapter cables, and disposable spiral fetal scalp electrodes and attachment electrodes. Facilities with surplus Avalon transducers from monitor fleet retirements can contact IPR Medical for an evaluation and offer.
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
| Product Condition |
|---|
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips Avalon Toco+ MP Transducer (M2735A). Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Compatible Fetal Monitors
| Avalon FM20 (M2702A) | Entry-level Avalon fetal/maternal monitor; accepts the M2735A on any of four fetal sensor sockets |
| Avalon FM30 (M2703A) | Adds DECG and IUP capability for internal monitoring; primary use case for the M2735A |
| Avalon FM40 (M2704A) | Alternative form factor of FM20 for ambulatory monitoring |
| Avalon FM50 (M2705A) | High-acuity Avalon fetal/maternal monitor with full noninvasive maternal vitals; supports M2735A in all modes |
DECG (Direct Fetal ECG) Accessories
| DECG Reusable Legplate Adapter Cable (M1362B) | Connects between the M2735A 7-pin auxiliary socket and the fetal spiral electrode; Philips catalog 989803137651 |
| Qwik Connect Plus Spiral Fetal Scalp Electrode (15133E) | Single-use fetal scalp electrode for DECG monitoring; sterile, packaged with insertion guide tube |
| Disposable Fetal Spiral Electrodes | Single-use spiral electrodes; Philips catalog 989803137631 and 989803137641 |
| Attachment Electrode for DECG (M1349A) | Self-adhesive grounding electrode applied to the patient’s thigh to complete the DECG circuit |
| Attachment Electrode (Direct ECG) (989803139771) | Alternative attachment electrode catalog reference for DECG circuit completion |
MECG (Maternal ECG) Accessories
| MECG Adapter Cable (M1363A) | Connects between the M2735A auxiliary socket and two pre-gelled foam electrodes for maternal ECG capture; pink connector color-coded to the transducer’s pink socket |
| Pre-gelled Foam Electrodes for MECG | Standard 3M, Ambu, or equivalent disposable foam electrodes compatible with the M1363A adapter cable; contact IPR Medical for current stock |
IUP (Intrauterine Pressure) Accessories
| IUP Adapter Cable TTIUP (M1334A) | Reusable connector cable between the M2735A auxiliary socket and Koala-style disposable sensor-tip IUP catheters |
| Disposable Sensor-Tip IUP Catheter | Single-use IUP catheter (Koala or equivalent sensor-tip design); contact IPR Medical for the specific OEM SKU matching your facility’s procurement standard |
Belts and Mounting
| Avalon Abdominal Belts | Disposable and reusable abdominal belts for securing Toco and US transducers to the maternal abdomen; SKU varies by length and material |
| Butterfly Belt Clip | Reusable clip that converts belts without buttonholes for use with the M2735A’s belt button |
Related Avalon Smart Transducers and Modules
| Avalon Toco Transducer (M2734A) | Original wired external Toco transducer without Smart Pulse or auxiliary connector |
| Avalon Toco MP Transducer (M2734B) | Wired external Toco with Smart Pulse but without the DECG/MECG/IUP auxiliary connector |
| Avalon Ultrasound Transducer (M2736A) | Wired external US transducer for fetal heart rate via Doppler; pairs with M2735A on the same monitor |
| Patient Module for ECG/IUP (M2738A) | Alternative wired DECG/MECG/IUP module that shares the same parameter frontends as the M2735A but without the Toco function |
| Avalon CL Toco+ MP Transducer (866075) | Cableless equivalent of the M2735A for use with the Avalon CL Base Station 866074 |
| Avalon CL ECG/IUP Transducer (866077) | Cableless wireless DECG/MECG/IUP transducer for the Avalon CL system |
Repair and Service Parts
| M2735A Cable Assembly Replacement | Replacement transducer cable with D-shaped main connector; addresses the most common failure mode on Avalon Smart Transducers. Contact IPR Medical for the specific replacement SKU matching your transducer revision. |
| M2735A Housing and Strain Gauge Assembly | Replacement housing parts for cases of physical damage to the Toco surface or strain gauge element. Contact IPR Medical to confirm OEM SKU for your revision. |
| Flat-Rate Repair Service | IPR Medical offers flat-rate functional repair on M2735A transducers, including connector replacement, cable replacement, and full DECG/MECG/IUP/Toco/Smart Pulse functional verification per Philips service manual procedures |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.