Philips Avalon CL Wireless Toco+ MP Transducer (866075)
The Philips Avalon CL Wireless Toco+ MP Transducer (866075) is the cableless uterine activity transducer in the Avalon CL Fetal Transducer System — measuring uterine contractions via external Toco while simultaneously capturing maternal pulse through integrated Smart Pulse technology. It also includes a multi-purpose connector that accepts maternal ECG, fetal ECG (DECG), or intrauterine pressure (IUP) sensors, making the 866075 one of the most versatile transducers on the L&D floor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor at ranges up to 100 m (300 ft) line of sight.
The 866075 is watertight for underwater monitoring, weighs only about 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.
IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
Philips Avalon CL Wireless Toco+ MP Transducer (866075) Specifications
The Philips 866075 is the cableless Toco+ MP transducer in the Avalon CL Fetal Transducer System. It combines external uterine activity (Toco) measurement with Avalon Smart Pulse for maternal pulse, plus a connector for maternal ECG, fetal ECG (DECG), or intrauterine pressure (IUP) sensors. It connects to the Avalon CL base station (866074) for use with Avalon FM20/FM30/FM40/FM50 fetal monitors.
| OEM Part Number | 866075 (Philips reference 453564423421) |
| Device Type | Cableless Toco+ MP transducer with Smart Pulse |
| Primary Measurement | External uterine activity (Toco) |
| Integrated Smart Pulse | Avalon Smart Pulse maternal pulse measurement for cross-channel verification (CCV) between maternal and fetal heart rate |
| Additional Measurements via Connector | Maternal ECG (MECG), fetal ECG (DECG), or intrauterine pressure (IUP) |
| Compatible Base Station | Philips Avalon CL Base Station (866074) |
| Compatible Fetal Monitors | Philips Avalon FM20, FM30, FM40, and FM50 |
| Required Monitor Software | Avalon fetal monitor software release J.3 or higher |
| Operating Range | Up to 100 m (300 ft) line of sight from base station |
| Wireless Technology | Philips IntelliVue Instrument Telemetry (Short-Range Radio, IEEE 802.15.4) |
| System Capacity | Up to 4 CL transducers and 2 IntelliVue CL Pods per base station |
| Twins/Triplets Support | Supported when used with additional CL ultrasound transducers |
| Power Source | Rechargeable Lithium-Ion battery (recharged via base station dock) |
| Water Protection | Watertight; rated for underwater monitoring (bath/shower use) |
| Applied Part Classification | Type CF, defibrillation-resistant patient connection |
| Ventilation Knob/Membrane | Pressure-equalization membrane on Toco sensor — requires periodic inspection per OEM maintenance schedule |
| Transducer Finder LED | Built-in LED indicator to locate and identify transducers during monitoring |
| Diameter | 3.27 in (83 mm) |
| Weight | Approximately 0.6 lbs (0.27 kg) |
| Materials | Latex-free housing; sealed non-user-serviceable enclosure |
| FDA Premarket Notification | K140535 |
| Intended Use | Continuous antepartum and intrapartum fetal and maternal monitoring in a healthcare facility |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Toco+ MP Transducer (866075). Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
Toco + Smart Pulse + MECG/DECG/IUP in one transducer
The Avalon CL Toco+ MP Transducer (866075) is the most versatile transducer in the Avalon CL family. Its primary function is external uterine activity monitoring via a pressure-sensitive Toco sensor on the patient’s abdomen. The “MP” designation refers to Avalon Smart Pulse — an integrated maternal pulse sensor built into the transducer housing that captures the mother’s pulse at the same location as the Toco. Beyond those two simultaneous measurements, the 866075 includes a multi-purpose connector that accepts either a maternal ECG cable, a fetal scalp electrode (DECG) lead, or an intrauterine pressure (IUP) catheter adapter — letting a single cableless transducer deliver up to three concurrent signal streams to the monitor.
Smart Pulse and cross-channel verification
One of the most significant clinical risks in fetal monitoring is mistaking a maternal heart rate for a fetal heart rate during labor, particularly when the fetal signal is weak or the mother’s heart rate is elevated. Avalon Smart Pulse addresses this directly. Because the 866075 captures the maternal pulse in the same location as the Toco, the Avalon monitor can run Cross-Channel Verification (CCV) continuously — automatically detecting when the maternal and fetal heart rates coincide and alerting clinicians before an FHR misinterpretation occurs. This capability is a core reason facilities standardize on Avalon CL for high-acuity L&D environments.
Cableless mobility for labor and delivery
Freedom of movement during labor is linked to patient comfort, shorter labor times, and better overall experience. The 866075 eliminates the patient cable entirely — the transducer communicates wirelessly with the Avalon CL Base Station (866074) over Philips IntelliVue Instrument Telemetry at ranges up to 100 m (300 ft) in line of sight. Mothers can walk the halls, use a birthing ball, shower, or labor in a tub without losing the uterine activity trace. The transducer housing is watertight, so underwater monitoring is explicitly supported for hydrotherapy and water birth protocols.
Works with the entire Avalon FM family
The 866075 is part of the Avalon CL system and requires the Avalon CL Base Station (866074). That base station in turn connects to any fetal sensor socket on the Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor — or to the rear telemetry connectors on the FM40 and FM50. Avalon fetal monitor software release J.3 or higher is required. Up to four CL transducers and two IntelliVue CL Pods can be assigned to a single base station, so a complete cableless kit can monitor twins or triplets plus maternal SpO2 and NBP simultaneously from one hub.
Automatic assignment, charging, and Transducer Finder
Setup is plug-and-play: dock the 866075 in any slot on the base station and it is automatically assigned, paired, and recharged. A green or yellow LED on the transducer confirms when it is ready for use, and the built-in Transducer Finder LED helps clinicians quickly identify which transducer on the patient corresponds to which trace on the monitor — useful when multiple CL transducers are in use for twins or during a shift change. The internal Lithium-Ion battery powers the device wirelessly throughout labor; charge status is reported to the fetal monitor, and low-battery, out-of-battery, loss-of-radio, and malfunction alarms are all built into the Avalon CL system so clinicians are alerted before the trace is interrupted.
Patient safety and construction
The 866075 is a Type CF applied part, meaning its patient connection is rated for direct cardiac application and is defibrillation-resistant — important given the MECG and DECG use cases on the auxiliary connector. The housing is latex-free and sealed at the factory. The Toco sensor includes a pressure-equalization ventilation membrane that requires periodic inspection per the Avalon CL maintenance schedule; IPR Medical includes this check in our standard 866075 service. The transducer is not user-serviceable for battery replacement, which requires the dedicated Philips CL transducer battery replacement tool used by authorized technicians.
IPR Medical — sales, repairs, parts, and service
IPR Medical sells refurbished and patient-ready Philips Avalon CL transducers and base stations, and we buy surplus or decommissioned units from facilities upgrading their fetal monitoring fleet. Our service team performs battery replacements, housing seal service, Toco membrane replacement, front-end repair, and functional testing on the 866075 using Philips-specified procedures. We also stock replacement belts, belt buttons, maternal ECG cables, DECG lead sets, and IUP catheter adapters used with the Avalon CL system — so a single call covers the transducer, the accessories, and the service that keeps it running.
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Toco+ MP Transducer (866075). Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
| Product Condition |
|---|
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips Avalon CL Wireless Toco+ MP Transducer (866075). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Avalon CL System Components
| 866074 | Philips Avalon CL Wireless Transducer Base Station — required for 866075 operation; supports up to 4 CL transducers and 2 CL Pods |
| 866075 | Philips Avalon CL Toco+ MP Cableless Transducer — this listing |
| 866076 | Philips Avalon CL Ultrasound Cableless Transducer — external fetal heart rate |
| 866077 | Philips Avalon CL ECG/IUP Cableless Transducer — MECG, DECG, and IUP measurement |
Compatible Fetal Monitors
| Avalon FM20 | Mid-tier Philips fetal monitor; connects to 866074 via fetal sensor socket (software J.3+ required) |
| Avalon FM30 | Mid-tier Philips fetal monitor with integrated maternal SpO2; connects to 866074 via fetal sensor socket (software J.3+ required) |
| Avalon FM40 | Advanced Philips fetal monitor; connects to 866074 via fetal sensor socket or rear telemetry connectors |
| Avalon FM50 | Top-tier Philips fetal monitor; connects to 866074 via fetal sensor socket or rear telemetry connectors |
IntelliVue CL Pods (Maternal Vital Signs)
| CL SpO2 Pod | Wireless maternal pulse oximetry pod; dockable on the 866074 base station alongside CL transducers |
| CL NBP Pod | Wireless maternal non-invasive blood pressure pod; enables untethered maternal vitals during labor |
Belts and Patient Accessories
| Transducer Belts (Reusable) | Washable, waterproof abdominal belts for Avalon CL transducers; button-style attachment |
| Transducer Belts (Single-Use) | Disposable abdominal belts for single-patient use; button-style attachment |
| Belt Buttons | Replacement belt attachment buttons for Avalon CL transducers |
Consumables for Auxiliary Connector (MECG/DECG/IUP)
| Maternal ECG Electrode Set | Single-use disposable ECG electrodes for maternal MECG monitoring through the 866075 connector |
| Fetal Scalp Electrodes | Single-use DECG electrodes compatible with the 866075 DECG lead interface |
| Maternal Leg Plate Electrode | Reference electrode used with DECG for fetal heart rate derivation |
| IUP Catheter (Compatible) | Intrauterine pressure catheter compatible with the 866075 IUP adapter; single-patient use |
Service and Replacement Parts
| CL Transducer Replacement Battery | Factory-spec rechargeable Lithium-Ion battery; installation requires Philips CL transducer battery replacement tool and qualified technician |
| CL Transducer Battery Replacement Tool | Philips-specified tool used to open and reseal CL transducer housings for authorized battery service |
| Toco Ventilation Knob/Membrane | Pressure-equalization membrane for Toco sensor; replacement part per Avalon CL preventive maintenance schedule |
| Base Station Power Cable | AC mains cable for the 866074 Avalon CL Base Station |
| Base Station Telemetry Interface Cable | Interface cable connecting the 866074 base station to the Avalon fetal monitor |
| Base Station Antenna | Standard antenna for 866074 Avalon CL base station; replacement and extension options available |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Toco+ MP Transducer (866075). Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Reviews
There are no reviews yet.