Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A
This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.
| Device Type | Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoring |
| Replaces / Cross Reference | M2725A cordless Toco transducer (also referenced as part 862488) |
| Compatible Monitors | Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A) |
| Patient Population | Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage area |
| Key Features | Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicators |
| Mounting | Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring belts |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.
Compatible Wireless Toco Transducer for Philips Avalon (M2725A) — Specifications
| Replaces / Cross Reference | M2725A cordless Toco transducer (also referenced as part 862488) |
| Device Type | Cordless (wireless) external tocodynamometer (Toco) transducer for non-invasive uterine activity monitoring |
| Intended Function | External, non-invasive monitoring of uterine activity (duration, frequency, and relative intensity of contractions) by detecting abdominal-wall hardness via a strain-gauge pressure sensor and transmitting the signal wirelessly to the host monitor’s cordless base |
| Sensor Type | Pressure-sensitive resistor bridge (DMS / strain-gauge element) with AC excitation; output amplified and rectified to a pressure-proportional DC signal before wireless transmission |
| Compatible Host Monitors | Philips Avalon FM20 (M2702A), Avalon FM30 (M2703A), Avalon FM40 (M2704A), and Avalon FM50 (M2705A) fetal/maternal monitors |
| Required Base Station | Philips Avalon CTS Cordless Fetal Transducer System (M2720A); only one CTS base station can be connected to a host monitor at a time |
| Wireless Transmission | Digital subcarrier transmission of Toco data along with serial number, bed label, fetal movement data, and battery status to the CTS base station; PLL-synthesized RF link |
| Mode Identification | Identified to the host monitor as “Toco External Mode” via the CTS interface; the host monitor automatically configures the Toco channel and screen layout when the cordless transducer is removed from the base station |
| Mixing With Wired Transducers | Not supported — the host monitor uses either wired or cordless transducers, not both simultaneously; switch between modes by docking or undocking transducers in the CTS base station |
| Multi-Pregnancy Monitoring | Cordless monitoring of multiple pregnancies (twins/triplets) is not supported by the CTS architecture; multi-pregnancy patients should be monitored with wired transducers |
| Power | Internal rechargeable battery; charged when the transducer is docked in the CTS base station |
| Housing & Patient Contact | Lightweight handheld form factor; waterproof housing intended to support patient mobility during labor, including shower/bath use; latex-free patient contact materials |
| Belt Attachment | Snap-clip belt fixing onto compatible reusable washable fetal belts (e.g., M1562A) or waterproof washable fetal belts (e.g., M1562B); also compatible with disposable abdominal belts (e.g., M2208A) |
| Coupling Medium | No coupling gel required (Toco transducers operate by mechanical pressure, not ultrasound) |
| Cleaning & Disinfection | Surface clean and disinfect per the host system’s instructions for use; do not steam-sterilize |
| Required Host Software | Compatible with Avalon FM20/FM30/FM40/FM50 monitors at supported software revisions (host monitor software revision D.00.00 or greater is required for full CTS support, including MECG/DECG modes on the FM30/FM50) |
| Regulatory Classification | Accessory to a Class II fetal cardiotocograph under 21 CFR 884.2660 (FDA Obstetrics/Gynecology panel); host monitor and base station cleared via 510(k) by their original manufacturer |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Overview
This is an aftermarket-compatible cordless Toco transducer offered by IPR Medical as a direct replacement for the M2725A wireless Toco fetal transducer used in the Philips Avalon Cordless Transducer System (CTS). It is intended to function as part of the Avalon cordless monitoring chain together with the Avalon CTS base station (M2720A) and a host Avalon fetal monitor — the FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), or FM50 (M2705A). Like the part it replaces, this transducer measures uterine activity externally by evaluating the hardness of the mother’s abdomen during contractions, then transmits the signal wirelessly to the CTS base station so the host monitor can render a continuous Toco trace on the integrated recorder. The cordless form factor is intended to support patient mobility during labor and delivery while keeping continuous CTG documentation in place. This is a compatible aftermarket part sold and supported by IPR Medical and is not manufactured by, affiliated with, or endorsed by Philips.
Display and User Interface
The compatible M2725A-style transducer has no display of its own; all numeric values, waveforms, alarms, and trace recording are presented on the host Avalon fetal monitor’s touchscreen and integrated thermal recorder. The transducer carries on-board status indicators that show pairing, battery charge state, and bed-identifier assignment so clinicians at the bedside can confirm the cordless link is active. When the transducer is removed from the CTS base station, the Avalon host monitor automatically reconfigures its on-screen layout to show cordless Toco data on the appropriate channel; redocking the transducer in the base station — or putting the base station into Stand-by — returns the host monitor to wired-transducer operation. Bed-label assignment and other configuration steps are performed at the host monitor and propagate to the cordless transducer through the CTS base station.
Strain-Gauge Operation and Wireless Transmission
External tocodynamometry detects uterine contractions indirectly. As the uterus tightens during a contraction, the abdominal wall stiffens and pushes outward against the Toco transducer; inside the transducer, that mechanical force deflects a movable base plate against a pressure-sensitive resistor bridge — a strain-gauge (DMS) element. AC excitation is applied to the bridge, and the resulting differential output is amplified and synchronously rectified to produce a pressure-proportional DC signal. That signal is digitized and transmitted to the CTS base station over a digital subcarrier together with the transducer’s serial number, bed label, fetal movement data (where supported by the host monitor), and battery status. The base station forwards the data to the host Avalon monitor, which displays the result as a relative-pressure Toco channel and prints it to the trace alongside FHR data from a paired cordless or wired ultrasound transducer. As with any wired Toco transducer, the displayed value is relative rather than calibrated absolute pressure, so the operator zeroes the trace between contractions using the host monitor’s Toco baseline control.
Compatibility with the Philips Avalon Family
The compatible M2725A-style cordless Toco transducer is designed to be used with the Philips Avalon FM20 (M2702A), Avalon FM30 (M2703A), Avalon FM40 (M2704A), and Avalon FM50 (M2705A) fetal/maternal monitors. All four monitors share the same cordless transducer ecosystem and are compatible with the Avalon CTS Cordless Fetal Transducer System base station (M2720A). Two operational rules apply across the Avalon family. First, only one CTS base station can be connected to a host monitor at a time. Second, wired and cordless transducers cannot be mixed during a single monitoring session; the operator selects either the wired chain or the cordless chain by docking or undocking the cordless transducers in the CTS base station and uses one chain at a time. Cordless monitoring of twins or triplets is not supported by the CTS architecture, so multi-pregnancy patients should be moved to wired transducers. If sufficient signal quality cannot be achieved on the cordless link — for example, in a labor room with significant RF interference or with a patient who has moved outside the CTS coverage radius — switching to wired transducers is the appropriate fallback documented in the host system’s instructions for use.
Patient Mobility, Belts, and Workflow
The cordless form factor’s primary clinical benefit is freedom of movement during labor. The transducer attaches to a fetal monitoring belt with a snap-clip belt fixing identical in interface to the wired Avalon transducers, so existing belts in a Labor and Delivery unit’s circulating stock continue to work. Compatible belts include reusable washable fetal belts (e.g., M1562A), waterproof washable fetal belts (e.g., M1562B) for showering and tub labor, and disposable abdominal belts (e.g., M2208A) for single-patient use. Because the transducer housing is waterproof, it can remain in place during showering and bathing without removing the patient from continuous CTG monitoring, provided the host monitor and CTS base station coverage area extend to the bathing location. After each patient, the transducer is wiped clean of skin oils and lotions, surface-disinfected per the host system’s care and cleaning instructions, and returned to the CTS base station to recharge between uses; it should not be steam-sterilized.
Service and Maintenance Considerations
Because the compatible M2725A-style transducer participates in a wireless, battery-operated monitoring chain, its failure modes are different from a wired Toco transducer. Common service-related issues include reduced battery runtime as the internal cell ages, intermittent radio link quality in environments with significant 2.4 GHz interference or after structural changes to a Labor and Delivery floor (new walls, new equipment, new wireless networks), drift of the strain-gauge baseline that cannot be zeroed at the host monitor, and damage to the housing seal that compromises the waterproof rating after drops or rough handling. Performance verification after any repair or maintenance event should follow the same performance and safety test sequence the host system’s service guide defines for the wired Toco channel, with the addition of cordless link verification at the CTS base station. Telemetry should not be used as the primary monitoring chain when momentary loss of the Toco signal would be unacceptable; in those cases the patient should be returned to a hard-wired transducer chain. IPR Medical’s biomed team can support facilities that need bench testing, evaluation, or replacement of compatible cordless Toco transducers as part of fleet maintenance on Avalon fetal monitors.
IPR Medical — Buy, Sell, Repair, and Parts
IPR Medical buys, sells, repairs, and stocks parts and accessories for the Philips Avalon fetal monitor family and the Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers offered as direct replacements for the M2725A. Whether your facility needs a single replacement cordless Toco transducer to bring an Avalon CTS chain back into service, additional cordless transducers to expand cordless monitoring across more Labor and Delivery beds, or evaluation and repair of an existing cordless transducer that is producing baseline drift, intermittent radio link, or short battery runtime, IPR Medical’s biomed team can support the request. We also buy back surplus Avalon monitors, CTS base stations, and cordless transducers from facilities upgrading their fetal monitoring fleet. Reach out for compatibility verification against your specific Avalon host monitor software revision, fleet sourcing for multi-bed deployments, and service questions on the host monitor or CTS base station.
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
| Product Condition |
|---|
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips Avalon Cordless Transducer System (CTS) and the Avalon FM20 / FM30 / FM40 / FM50 fetal monitor family on which the M2725A-compatible cordless Toco transducer is used. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Cordless (Wireless) Transducers — Avalon CTS
| Cordless Toco Transducer (M2725A / 862488) | Aftermarket-compatible wireless Toco transducer for measuring uterine activity through the Avalon CTS base station; replaces the M2725A. |
| Cordless Ultrasound Transducer (M2726A / 862489) | Companion cordless ultrasound transducer for fetal heart rate via the Avalon CTS base station. |
| Cordless ECG Transducer (M2727A / 862490) | Companion cordless ECG transducer for direct fetal ECG and maternal ECG (depending on host monitor configuration) via the Avalon CTS base station. |
Avalon CTS Base Station
| Avalon CTS Cordless Fetal Transducer System (M2720A) | Cordless transducer base station that pairs with the M2725A cordless Toco transducer (and companion cordless US/ECG transducers) and connects to the Avalon FM20/FM30/FM40/FM50 host monitor. |
Compatible Avalon Host Monitors
| Avalon FM20 (M2702A) | Antepartum fetal/maternal monitor; supports cordless Toco via the M2725A on the CTS base station. |
| Avalon FM30 (M2703A) | Antepartum and intrapartum fetal/maternal monitor with internal monitoring options; cordless Toco supported at host software revision D.00.00 or greater. |
| Avalon FM40 (M2704A) | Antepartum fetal/maternal monitor in alternate form factor; cordless Toco supported at host software revision D.00.00 or greater. |
| Avalon FM50 (M2705A) | Antepartum and intrapartum fetal/maternal monitor with internal monitoring options; cordless Toco supported at host software revision D.00.00 or greater. |
Belts and Belt Accessories
| Reusable Washable Fetal Belts (M1562A / 989803104111) | Standard reusable abdominal belts for cordless and wired Avalon transducers; supplied in packs of 3. |
| Waterproof Washable Fetal Belts (M1562B / 989803129891) | Reusable waterproof belts intended for use with cordless transducers during shower/bath labor; supplied in packs of 3. |
| Disposable Abdominal Belts (M2208A / 989803106021) | Single-patient-use disposable abdominal belts for Avalon transducers; supplied in cases of 100. |
Companion Wired Transducers and Patient Modules
| Wired Toco / Toco+ Transducer (Avalon) | Wired external Toco transducer for use directly on the host Avalon monitor when the cordless chain is not available; Toco+ adds maternal pulse measurement on supported FM30/FM50 configurations. Contact IPR Medical for the specific part number matching your Avalon configuration. |
| Wired Ultrasound Transducer (Avalon) | Wired ultrasound transducer for FHR monitoring on the host Avalon monitor. Contact IPR Medical for the specific part number matching your Avalon configuration. |
| DECG Adapter Cable (M1362B / 989803103551) | Adapter cable for direct fetal ECG monitoring on FM30 / FM50 monitors when paired with a compatible patient module. |
| MECG Adapter Cable (M1363A / 989803103561) | Adapter cable for maternal ECG monitoring on Avalon monitors; for use with M1364A or M1365A patient modules. |
Recorder Paper and Consumables
| Avalon Trace Paper | Thermal Z-fold trace paper for the Avalon FM20/FM30 and FM40/FM50 integrated recorders; scaling and form factor vary by monitor model and region. Contact IPR Medical for the specific part number matching your Avalon model and region. |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.