Philips Compatible M1355A External Toco Transducer | Series 50
The Philips M1355A is the external tocodynamometer (Toco) transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It uses a strain-gauge–based pressure sensor strapped over the fundus of the maternal abdomen to detect the duration, frequency, and relative intensity of uterine contractions, and it pairs with the M1356A ultrasound transducer to provide a complete external CTG trace.
| Device Type | External tocodynamometer (Toco) transducer for non-invasive uterine activity monitoring |
| Compatible Monitors | Philips Series 50 A (M1351A Single and Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 fetal monitors |
| Patient Population | Antepartum and intrapartum monitoring of uterine activity |
| Connector | Keyed round multi-pin connector to the dedicated Toco socket on the Series 50 monitor |
| Mounting | Snap-clip to M1562A reusable transducer belt; transducer knob adapter (M1356-43201) optional |
| Housing Color Variants | Brown (M1355-60001) and Blue (M1355-60011) — color matches monitor housing |
IPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact us at 855-477-8866 or cs@iprmed.com.
Philips M1355A External Toco Transducer — Specifications
| Manufacturer | Philips Healthcare |
| Model | M1355A External Toco Transducer |
| Color Variants | Brown (P/N M1355-60001) and Blue (P/N M1355-60011); housing color is selected to match the Series 50 monitor it is paired with |
| Device Classification | Accessory to a fetal cardiotocograph (CTG) — non-invasive external tocodynamometer for uterine activity |
| Intended Use | External, non-invasive monitoring of uterine activity (duration, frequency, and relative intensity of contractions) using a strain-gauge pressure sensor applied to the maternal abdomen |
| Compatible Monitors | Philips Series 50 A (M1351A Single Ultrasound and Dual Ultrasound Twins), Series 50 IP-2 (M1353A); also used with earlier Philips/HP M1350 series fetal monitors |
| Monitor Socket Used | Dedicated Toco socket on the front face of the Series 50 monitor (separate from the US, US1, and US2/ECG sockets) |
| Sensor Type | Strain-gauge pressure transducer with a movable base plate that detects abdominal-wall tension changes during uterine contractions |
| Baseline / Zeroing | Toco baseline key on the monitor zeroes the Toco display and trace to 20 units (relative units) when monitoring externally; coupling gel is not required |
| Belt Attachment | Integrated snap-clip designed to slide on M1562A reusable transducer belt; optional fixing-button adapter (M1356-43201) supplied with the Series 50 monitor |
| Patient Contact Material | Latex-free; no coupling gel required for external Toco |
| Compatible Accessories | Reusable transducer belt M1562A; transducer knob adapter M1356-43201 |
| Cleaning & Disinfection | Surface clean and disinfect per Series 50 IFU; do not immerse the transducer in liquid while connected to the monitor; do not steam-sterilize |
| Reference Documentation | Philips Series 50 A (M1351A) / Series 50 IP-2 (M1353A) Instructions for Use (M1353-9001J) and Service and Installation Guide (M1353-9000J) |
| Regulatory Classification | Accessory to a Class II fetal cardiotocograph under 21 CFR 884.2660 (FDA Obstetrics/Gynecology panel); host monitor cleared via 510(k) by the original manufacturer |
| FDA Device Corrections | An FDA Class 2 device recall record exists for the External Toco Transducer (M1355A) in the FDA Medical Device Recalls Database (Recall Event ID 175941). See the Description Tab for further detail and links to the FDA’s official record. |
IPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Overview
The Philips M1355A is the external tocodynamometer (Toco) transducer designed for use with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) Single Ultrasound model, the Series 50 A Dual Ultrasound Twins model, and the Series 50 IP-2 (M1353A) intrapartum model. It is also used as a service replacement on earlier Philips/HP M1350 series monitors. The transducer is strapped to the maternal abdomen — typically over the fundus uteri, the area where contraction-induced tension changes are most pronounced — and uses a strain-gauge pressure sensor with a movable base plate to convert mechanical force into an electrical signal. The host monitor processes that signal into a continuous Toco trace on the integrated thermal recorder, providing the “uterine activity” channel of a complete external cardiotocograph (CTG) study. The M1355A is intended for both antepartum and intrapartum external monitoring and is paired with the M1356A ultrasound transducer for FHR.
Connector, Cable, and Belt Attachment
The M1355A terminates in a keyed round multi-pin connector that mates with the dedicated Toco socket on the front face of the Series 50 monitor. This Toco socket is physically and electrically distinct from the US, US1, and US2/ECG sockets used by the M1356A ultrasound transducer, the M1357A DECG legplate, and the M1359A MECG transducer, so the monitor automatically recognizes the connected transducer type and selects the correct operating mode without operator action. On the M1353A Series 50 IP-2, the Toco socket can additionally accept the M1350A / 8040A compatible internal Toco transducer when intrauterine pressure (IUP) monitoring is being substituted for external Toco. The transducer body includes a snap-shut clip that secures it to the M1562A reusable abdominal belt and is designed to slide along the belt for repositioning during monitoring; an optional transducer knob adapter (M1356-43201) is available where the buttoned belt-attachment style is preferred.
Strain-Gauge Operation and Baseline Behavior
External tocodynamometry detects uterine contractions indirectly. As the uterus tightens during a contraction, the abdominal wall over the fundus stiffens and pushes outward against the Toco transducer, deflecting its movable base plate. A strain gauge inside the transducer housing converts that deflection into an electrical signal proportional to the relative contraction force. The Series 50 monitor displays the result in unitless relative pressure on the Toco channel and on the right-hand scale of the recorder paper. Because the signal is relative rather than calibrated absolute pressure, the Toco baseline key on the monitor is used to zero the trace to 20 units between contractions (or to 0 units when an internal IUP transducer is in use on the IP-2). Belt tightness, transducer placement over the fundus, and patient body habitus all affect signal amplitude, so brief repositioning of the transducer or re-tensioning of the belt is normal during a study. Unlike the M1356A ultrasound transducer, the M1355A does not use ultrasound coupling gel and is not affected by gel availability or contact medium quality.
Compatibility with the Series 50 Monitor Family
The M1355A is the standard external Toco transducer specified for the Series 50 A and Series 50 IP-2 monitors in the Philips Instructions for Use and Service and Installation Guide. The Series 50 A Single Ultrasound model, the Series 50 A Dual Ultrasound Twins model, and the Series 50 IP-2 (M1353A) all ship with one M1355A as a standard accessory. Philips supplied the transducer in two housing color variants — Brown (M1355-60001) and Blue (M1355-60011) — to color-match the monitor cabinet; the two variants are functionally identical and are interchangeable on any Series 50 Toco socket regardless of monitor housing color. The M1355A is also commonly used as a service replacement on the earlier Hewlett-Packard / Philips M1350 series fetal monitor lineage from which the Series 50 platform evolved. When monitoring uterine activity together with FHR on a Series 50 monitor, the M1355A and M1356A are typically applied simultaneously using two M1562A belts.
Use with Belts and the Series 50 Workflow
The M1355A is held in position with the M1562A reusable abdominal belt, fastened around the mother with the fixing button positioned to one side and the loose ends arranged so they remain at the patient’s side rather than under her body. Two belts are typically used when monitoring uterine activity and FHR simultaneously, and three belts are supplied with twin and IP-2 configurations. After the belt is in place, the operator palpates for the fundus, positions the M1355A over that area, snaps it onto the belt, tensions the belt to a comfortable but firm fit, and presses the Toco baseline key on the monitor to zero the trace between contractions. The recorder then prints the Toco channel on the right-hand side of the trace paper, alongside the FHR channel from the M1356A ultrasound transducer on the left, producing the standard external CTG layout. Belts are reusable and should be cleaned per the IFU between patients; the transducer body itself should be wiped clean and surface-disinfected per the Care and Cleaning chapter of the IFU and never immersed in liquid while connected to the monitor.
Service, Testing, and Preventive Maintenance
The Philips Series 50 Service and Installation Guide (M1353-9000J) defines a structured Toco parameter test that biomedical staff use to validate M1355A function in the field. The Series 50 monitor includes a built-in Self Test, Quick Test, and Parameter Test, and the dedicated Toco Parameter Test exercises the front-end Toco circuitry together with an attached M1355A to confirm correct strain-gauge response and baseline behavior. Common bench failures on aged Toco transducers include drifting baseline that cannot be zeroed (typically pointing to strain-gauge degradation or moisture ingress at the base plate), intermittent signal as the patient moves (often cable flex damage near the strain relief or at the connector backshell), and connector pin damage from repeated insertion and removal. The Service Guide identifies the transducer as a field-replaceable unit; component-level repair of the strain-gauge assembly is not recommended by Philips, and the standard remedy for a failed transducer is replacement of the assembly. Routine preventive maintenance is described in the Care and Cleaning chapter of the IFU and the Regular Maintenance section of the Service Guide.
Service and Maintenance Considerations
The M1355A is a passive strain-gauge transducer rather than a networked device and has no software, cybersecurity, or EMR integration of its own; data transmission, alerts, trend storage, and integration with obstetrical surveillance systems such as Philips OB TraceVue are handled by the host Series 50 monitor and its optional Combined Interface Module or Modem Interface Module. From a clinical engineering perspective the transducer should be inspected at each preventive maintenance interval for housing cracks, wear of the patient-contact base plate, cable jacket integrity, strain-relief integrity at both the transducer body and the monitor connector, and connector pin condition. Because the M1355A does not use coupling gel and has no ultrasound emitting element, its failure modes are different from the M1356A and tend to manifest as baseline drift, sluggish response to contractions, or amplitude loss rather than signal-quality faults. IPR Medical’s biomed team can support facilities that need bench testing, evaluation, or replacement of M1355A transducers as part of fleet maintenance on Philips Series 50 monitors.
FDA Device Corrections and Safety Bulletins
A Class 2 medical device recall record exists in the FDA Medical Device Recalls Database for the External Toco Transducer (M1355A) under Recall Event ID 175941. Class 2 indicates a situation in which use of, or exposure to, the device may cause temporary or medically reversible adverse health consequences, and the probability of serious adverse health consequences is remote. IPR Medical recommends that clinical engineering teams review the FDA’s official record for this recall directly to confirm the affected lot or date ranges, the recalling firm’s reference and reason, the specific corrective action requested, and the current status of the recall, because these details may be updated by FDA after the date of this listing. Facilities operating Philips Series 50 fetal monitors should also review the broader Philips fetal-monitoring transducer safety communications referenced on the Philips customer support portal, including any field correction or service notices that affect transducers refurbished beyond their useful life.
Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.
FDA resources for further review:
FDA Medical Device Recalls Database |
FDA Medical Device Safety
IPR Medical — Buy, Sell, Repair, and Parts
IPR Medical buys, sells, repairs, and stocks parts and accessories for the Philips Series 50 fetal monitor family, including the M1355A external Toco transducer in both Brown and Blue housing variants. Whether your facility needs a single replacement Toco transducer to bring a Series 50 A or Series 50 IP-2 back into service, a bench-tested unit for a Labor and Delivery floating cart, or evaluation and repair of an existing M1355A that is producing baseline drift or amplitude loss, IPR Medical’s biomed team can support the request. We also buy back surplus Series 50 monitors and accessories from facilities decommissioning older fetal monitor fleets, and can supply matching M1356A ultrasound transducers, M1357A DECG legplates, M1359A MECG transducers, M1364A patient modules, and thermal recorder paper to keep existing units in service. Reach out for color confirmation, lot/serial verification against current FDA recall scope, and service or software questions on the host monitor.
IPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
| Product Condition |
|---|
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips M1355A external Toco transducer and the Philips Series 50 fetal monitor family on which it is used. The sections below cover the most commonly requested companion components with part numbers where confirmed by Philips Series 50 documentation. Some accessory SKUs vary by monitor configuration (Single Ultrasound, Dual Ultrasound Twins, IP-2), region, and revision, so part numbers should be verified for your specific monitor before ordering. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Heart Rate and Activity Transducers
| External Toco Transducer, Brown (M1355A) | Strain-gauge external tocodynamometer for uterine activity; brown housing variant for color-matched monitors (M1355-60001). |
| External Toco Transducer, Blue (M1355A) | Strain-gauge external tocodynamometer for uterine activity; blue housing variant for color-matched monitors (M1355-60011). |
| Ultrasound Transducer (M1356A) | Wide-beam Doppler ultrasound transducer for fetal heart rate; supplied in brown (M1356-60001) and blue (M1356-60011) housing variants. |
| DECG Transducer / Legplate (M1357A) | Direct fetal ECG legplate for use with fetal scalp electrodes on the Series 50 IP-2 (M1353A). |
| MECG Transducer (M1359A) | Maternal ECG transducer for the Series 50 IP-2 US2/ECG socket. |
| DECG/MECG Patient Module (M1364A) | Patient-worn module that accepts DECG legplate adapter cable M1362B and MECG adapter cable M1363A. |
IUP Transducers (Internal Toco Alternative on Series 50 IP-2)
| IUP Quartz Transducer (1290C, option J05) | Reusable intrauterine pressure transducer used as an internal alternative to the M1355A external Toco on the Series 50 IP-2. |
| IUP Pressure Transducer (CPJ840J5) | Disposable IUP pressure transducer used with compatible IUP catheters on the Series 50 IP-2. |
Belts and Belt Accessories
| Reusable Transducer Belt (M1562A) | Standard reusable abdominal belt for securing the M1355A and M1356A to the maternal abdomen; supplied two with Series 50 A Single Ultrasound and three with Twins / IP-2 configurations. |
| Transducer Knob Adapter (M1356-43201) | Optional fixing-button adapter for attaching the M1355A or M1356A to the abdominal belt via a buttoned mounting style. |
DECG / MECG Cables and Electrodes
| DECG Legplate Adapter Cable (M1362B) | Adapter cable that connects the M1357A DECG legplate to the M1364A patient module on the Series 50 IP-2. |
| MECG Adapter Cable (M1363A) | Adapter cable that connects MECG electrodes to the M1364A patient module. |
| Disposable Spiral Scalp Electrode, Single (15133D) | Single-spiral fetal scalp electrode (US configuration) supplied with M1353A IP-2 monitors. |
| Disposable Spiral Scalp Electrode, Double (15133E) | Double-spiral fetal scalp electrode (Europe configuration) supplied with M1353A IP-2 monitors. |
Coupling Gel and Disposables (for Companion Ultrasound Channel)
| Aquasonic Ultrasound Coupling Gel (40483A) | ultrasound coupling gel supplied with Series 50 monitors; required for use with the M1356A ultrasound transducer (the M1355A Toco transducer itself does not require gel). |
Recorder Paper
| Series 50 Trace Paper, USA / Canada (M1910A) | thermal Z-fold recorder paper for the Series 50 internal recorder; US/Canada scaling. |
| Series 50 Trace Paper, Europe (M1911A) | thermal Z-fold recorder paper for the Series 50 internal recorder; European scaling. |
| Series 50 Trace Paper, Japan (M1913A) | thermal Z-fold recorder paper for the Series 50 internal recorder; Japan scaling. |
Remote Event Marker and Interface Modules
| Remote Event Marker (15249A) | Patient-held event marker that connects to the dedicated event marker socket on the Series 50 monitor. |
| Combined Interface Module | Optional add-on interface module providing RS232 serial, NIBP monitor, FSpO₂, and barcode reader connectivity. Contact IPR Medical for the specific part number matching your Series 50 revision. |
| Modem Interface Module | Optional add-on module supporting trace transmission to obstetrical surveillance systems via a PCMCIA modem. Contact IPR Medical for the specific part number matching your Series 50 revision. |
Field-Replaceable Boards (Series 50 Host Monitor)
| Front End Board, M1351A (M1353-66501 / M1353-66511) | Front-end signal acquisition board for M1351A Series 50 A monitors; revision varies by build. |
| Front End Board, M1353A (M1353-66512 / M1350-66517) | Front-end signal acquisition board for M1353A Series 50 IP-2 monitors; revision varies by build. |
| Power Supply Board (M1353-66502) | Mains and battery power supply board for the Series 50 chassis. |
| CPU Board (M1353-66503 / M1353-66513) | Main CPU board for the Series 50 platform; revision varies by build and software level. |
| Display Board (M1350-66520) | Front-panel digital display board. |
| Recorder Interface Board (M1353-66510) | Interface board for the integrated thermal strip-chart recorder. |
IPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.