Philips M1193A Compatible Neonate Wrap SpO2 Sensor, Philips FAST, 6.6 ft (2.0 m)
The M1193A compatible neonate wrap SpO2 sensor (SKU SS-024-NW20) is a reusable aftermarket replacement (not OEM) with a wrap design and a 6.6 ft (2.0 m) cable, for use with the SpO2 technology shown in the table below.
| Sensor Type | Wrap |
| Patient Size | Neonate |
| SpO2 Technology | Philips FAST |
| Cable Length | 6.6 ft (2.0 m) |
| Lifecycle | Reusable |
| Replaces | Philips M1193A |
Works with: the monitor models listed in the Specifications tab. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and neonatal SpO2 accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-024-NW20 |
| Replaces OEM Part | Philips M1193A |
| Category | Cables & Sensors > SpO2 |
| Sensor Type | Wrap |
| Patient Size | Neonate |
| SpO2 Technology | Philips FAST |
| Cable Length | 6.6 ft (2.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Goldway | G40 |
| Mindray / Datascope | V12 |
| Philips | 862108, 862231, 862439, 862472, 862474 C3, 863063 VM4, 863064, 863065, 863066, 863068, 863071, 863071 VS3, 863072, 863073, 863074, 863077, 863080, 863081, 863082, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, Avalon FM20, Avalon FM30, Avalon FM40, Avalon FM50, C1, C3, Codemaster 100, HeartStart 4000, HeartStart MPx, HeartStart MRx, HeartStart XL, HeartStart XLT, Heartstream XL, IntelliVue MP5SC, IntelliVue MP5T, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, IntelliVue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M3, M4, M1020A, M1020B, M1350A, M1350C, M2475B, M2601A, M2601B, M2702A, M2703A, M2704A, M2705A, M3000A, M3001A, M3001A A01, M3001A A01C06, M3001A A01C12, M3001A A01C18, M3002A MMS X2, M3002A Opt. C12, M3046A (M4 chip), M3046A M3, M3500B, M3535A, M3536A, M3536M, M4735A, M4841A, M5500B, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, M8102A Opt.C12 MP2, M8105A, M8105A MP5, M8105A Opt. C12 MP5, M8105AS, M8105AT, MX4841A, MX Series, P60E, SureSigns VM1, SureSigns VM4, SureSigns VM6, SureSigns VM8, SureSigns VS2, SureSigns VS2+, SureSigns VS3, SureSigns VS4, SureSigns VSi, TRx 4851A, TRx M4841A, TRx+ M4841A, Viridia 24C, Viridia 50 XMO |
| Solaris | NT2A, NT2C |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | M1193A, 989803205881, 989803103241 |
| Sage | P013-30M |
| Unimed | U308-91, U303-91 |
IPR Medical buys, sells, repairs, and stocks parts for neonatal SpO2 sensors and the monitors that support them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the M1193A Compatible Neonate Wrap SpO2 Sensor?
The IPR Medical SS-024-NW20 is a compatible aftermarket (not OEM) neonate wrap SpO2 sensor that replaces OEM part M1193A. Made for neonatal patients, this reusable sensor has a wrap-style design and a 6.6 ft (2.0 m) cable, and it is intended for use with the SpO2 technology identified in the Specifications table.
Compatible Monitor Models
Most entries in the Compatible Monitor Models table are monitors from the original equipment manufacturer, shown with their model names and numbers on the Specifications tab. A few other brands appear as well, including select Solaris models (NT2A and NT2C) and the Mindray / Datascope V12. Match your monitor against that table before ordering, particularly in neonatal units that run equipment from more than one manufacturer.
Design and Construction
The sensor pairs a wrap design sized for neonates with a 6.6 ft (2.0 m) cable. Each sensor is reusable and comes bagged individually. Clean it between patients under facility protocol, and check the wrap, the cable, and the connector for wear each time before it is applied.
When to Replace Your Neonate Wrap SpO2 Sensor
Signs that a wrap sensor needs replacing include a wrap that is frayed, stretched, or no longer holds securely, a cable with cuts, kinks, or a cracked jacket, and a connector with bent pins. On the monitor, watch for unstable SpO2 values, a pulse rate that disagrees with the patient, or sensor-off alarms during routine handling. Trying a known-good sensor on the same monitor confirms where the fault lies.
Cross Reference and Interchange Part Numbers
OEM part M1193A is the number this sensor replaces, and it also cross-references to OEM numbers 989803205881 and 989803103241. Check the Specifications tab for the rest; its Cross Reference / Interchange Part Numbers table groups every number by brand.
Why Source Neonatal SpO2 Sensors from IPR Medical?
Neonatal care teams need a working sensor ready when a patient arrives. IPR Medical holds ISO 9001:2015 certification as an independent service organization, and in-house technicians handle every repair we take on. Our business is buying, selling, repairing, and stocking parts for patient monitoring equipment and infusion pumps; call 855-477-8866 with questions about an order, or see our full line of SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for neonatal SpO2 sensors and the monitors that support them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.