IPR Medical

Philips M1195A Compatible Infant Soft Tip SpO2 Sensor, Philips FAST, 6.6 ft (2.0 m)

$90.00

The M1195A compatible infant soft tip SpO2 sensor (SKU SS-024-IS20) is a reusable aftermarket replacement (not OEM) with a soft tip design and a 6.6 ft (2.0 m) cable, for use with the SpO2 technology shown in the table below.

Sensor Type Soft Tip
Patient Size Infant
SpO2 Technology Philips FAST
Cable Length 6.6 ft (2.0 m)
Lifecycle Reusable
Replaces Philips M1195A

Works with: the monitor models listed in the Specifications tab. Browse more SpO2 sensors and cables.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors and infant SpO2 accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: SS-024-IS20 Categories: , Tags: ,
Send In Philips M1195A Compatible Infant Soft Tip SpO2 Sensor, Philips FAST, 6.6 ft (2.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SS-024-IS20
Replaces OEM Part Philips M1195A
Category Cables & Sensors > SpO2
Sensor Type Soft Tip
Patient Size Infant
SpO2 Technology Philips FAST
Cable Length 6.6 ft (2.0 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Goldway G40
Mindray / Datascope V12
Philips 862108, 862231, 862439, 862472, 862474 C3, 863063 VM4, 863064, 863065, 863066, 863068, 863071, 863071 VS3, 863072, 863073, 863074, 863077, 863080, 863081, 863082, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, Avalon FM20, Avalon FM30, Avalon FM40, Avalon FM50, C1, C3, Codemaster 100, HeartStart 4000, HeartStart MPx, HeartStart MRx, HeartStart XL, HeartStart XLT, Heartstream XL, IntelliVue MP5SC, IntelliVue MP5T, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, IntelliVue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M3, M4, M1020A, M1020B, M1350A, M1350C, M2475B, M2601A, M2601B, M2702A, M2703A, M2704A, M2705A, M3000A, M3001A, M3001A A01, M3001A A01C06, M3001A A01C12, M3001A A01C18, M3002A MMS X2, M3002A Opt. C12, M3046A (M4 chip), M3046A M3, M3500B, M3535A, M3536A, M3536M, M4735A, M4841A, M5500B, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, M8102A Opt.C12 MP2, M8105A, M8105A MP5, M8105A Opt. C12 MP5, M8105AS, M8105AT, MX4841A, MX Series, P60E, SureSigns VM1, SureSigns VM4, SureSigns VM6, SureSigns VM8, SureSigns VS2, SureSigns VS2+, SureSigns VS3, SureSigns VS4, SureSigns VSi, TRx 4851A, TRx M4841A, TRx+ M4841A, Viridia 24C, Viridia 50 XMO
Solaris NT2A, NT2C

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips M1195A, 989803103261
AMC PR-A800-1006V
Sage P018S-30M
Unimed U208S-91, U203S-91

IPR Medical buys, sells, repairs, and stocks parts for infant SpO2 sensors and the patient monitors they work with. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the M1195A Compatible Infant Soft Tip SpO2 Sensor?

The IPR Medical SS-024-IS20 is a compatible aftermarket (not OEM) infant soft tip SpO2 sensor that replaces OEM part M1195A. Sized for infants, it pairs a soft tip with a 6.6 ft (2.0 m) cable, and the Specifications table identifies the SpO2 technology it works with. It is built for repeated use, with cleaning between patients.


Compatible Monitor Models

Infant care areas can confirm fit in the Compatible Monitor Models table on the Specifications tab, which lists the original equipment manufacturer’s monitors by model name and number. Other brands are in the table too, among them select Solaris models (the NT2A and NT2C) and the Mindray / Datascope V12. Before you order, find your monitor in that table.


Design and Construction

A soft tip sized for infants is joined to a 6.6 ft (2.0 m) cable on this reusable sensor, which is packed one per bag. Clean the sensor between patients per facility protocol. Small sensors are easy to overlook during routine checks, so give the tip, the cable, and the connector a careful look before each use.


When to Replace Your Infant Soft Tip SpO2 Sensor

Start with what you can see: a split or hardened soft tip, a cable jacket with cuts, cracks, or tight kinks, and a connector with bent pins all mean the sensor should come out of service. Performance clues include SpO2 values that wander, intermittent loss of signal, and alarms that clear only when the cable is repositioned. If you are unsure, compare the results against a known-good sensor on the same monitor.


Cross Reference and Interchange Part Numbers

Along with OEM part M1195A, OEM number 989803103261 cross-references to this compatible sensor. If you order by another brand’s part number, look it up in the Cross Reference / Interchange Part Numbers table on the Specifications tab.


Why Source Infant SpO2 Sensors from IPR Medical?

IPR Medical’s technicians perform repairs in-house. Alongside that repair work, we buy, sell, and stock parts for patient monitoring equipment and infusion pumps, operating as an ISO 9001:2015-certified independent service organization. Reach our team at 855-477-8866, or look over the rest of our SpO2 sensors and cables.

IPR Medical buys, sells, repairs, and stocks parts for infant SpO2 sensors and the patient monitors they work with. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.