Philips M1977A Compatible 5-Lead One-Piece ECG Cable, Snap, AHA, Defib-Proof, 8.2 ft + 3.0 ft (2.5 m + 0.9 m)

$70.00

The M1977A compatible 5-lead one-piece ECG cable (SKU EC-5005RS-A) is a reusable aftermarket replacement (not OEM) with snap electrode ends, limb and chest lead placement, AHA color coding, a defib-proof feature, and an 8.2 ft + 3.0 ft (2.5 m + 0.9 m) length, intended for monitoring.

Lead Count 5-Lead
Lead Placement Limb + Chest Lead
Electrode End Snap
AHA/IEC Code AHA
Cable Length 8.2 ft + 3.0 ft (2.5 m + 0.9 m)
Replaces Philips M1977A

Works with: the monitor models listed in the Specifications tab. See more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors, ECG cables, and related accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: EC-5005RS-A Categories: , Tags: ,
Send In Philips M1977A Compatible 5-Lead One-Piece ECG Cable, Snap, AHA, Defib-Proof, 8.2 ft + 3.0 ft (2.5 m + 0.9 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) EC-5005RS-A
Replaces OEM Part Philips M1977A
Category Cables & Sensors > ECG/EKG
Product One-Piece ECG Cable
Lead Count 5-Lead
Lead Placement Limb + Chest Lead
Electrode End Snap
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Cable Length 8.2 ft + 3.0 ft (2.5 m + 0.9 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Konsung Aurora 12s
Newtech NT3A
Nihon Kohden NT3B, Omnicare CMA
Philips 43100A, 43110A, 43120A, 78352C, 78354A/C, 78354C, 78355C, 78834A/B/C, 78834C, 860335, 862472, 862473, 862474, 862474 C3, 862475, 862475 C3, 862478, 862478 C3, 862479, 862479 C3, 863053, 863054 C1, 863064, 863065, 863066, 863066A, 863068, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, C3, C Series, CX50, Efficia CM10 (863301), Efficia CM12 (863303), Efficia CM100 (863300), Efficia CM120 (863302), Efficia CM150 (863304), Envisor, EPIQ, HD15, HeartStart MRx, HeartStart XL, IE33, IntelliVue MP5, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX700 Masimo Rainbow, IntelliVue MX800, IntelliVue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M2, M3, M4, M1001A, M1001B, M1002A, M1002B, M1094A, M1094B, M1165A, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1264A, M1275A, M1275A Transport, M1276A, M1280A, M1722A, M1722B, M1723A, M1723B, M1770A, M1771A, M1772A, M2475B, M2601A, M2601B, M2662A, M3000A, M3001A, M3001A Opt. C12, M3001A Opt. C18, M3002A, M3002A MMS X2, M3046A, M3046A (M4 chip), M3046A M3, M3535A, M3536A, M3536M, M3923A, M3924A, M3926A, M3927A A3, M3928A A3, M3929A, M4735A, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, M8102A Opt.C12 MP2, M8105A, M8105A MP5, M41764A, M417645A, Merlin, P60E, SureSigns VM6, SureSigns VM8, TRx4851A, V24, V24E, V26, Viridia 24, Viridia 24C, VM4
Solaris NT3C, NT3E, NT3F
Welch Allyn 242, Propaq Encore 206EL

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips M1977A, M1986A, 989803160791
AMC CB-72585R
Curbell CBM-05JA-10AS-0121
Sage A01-05S

IPR Medical buys, sells, repairs, and stocks parts for one-piece 5-lead ECG cables and the patient monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the M1977A Compatible 5-Lead One-Piece ECG Cable?

The IPR Medical EC-5005RS-A is a compatible aftermarket (not OEM) 5-lead one-piece ECG cable that replaces OEM part M1977A. It connects to the patient through five snap electrode ends arranged for limb and chest lead placement, and since the leads are integral to the cable, no separate leadwire set is needed. Monitoring is its intended use, and it is both reusable and defib-proof, with AHA lead designation.


Compatible Monitor Models

The Compatible Monitor Models table on the Specifications tab carries the full list for OEM part M1977A, the great majority of it original-equipment models. The list also takes in select Welch Allyn models (the 242 and the Propaq Encore 206EL) and select Solaris models (NT3C, NT3E, and NT3F), plus select Newtech, Nihon Kohden, and Konsung models such as the NT3A, NT3B, and Aurora 12s. Matching your model number against the table is the surest way to order correctly.


Design and Construction

On the EC-5005RS-A, each of the five leads ends in a snap connector, and AHA color coding identifies them: white for RA, black for LA, red for LL, green for RL, and brown for the V lead. Its length is listed as 8.2 ft + 3.0 ft (2.5 m + 0.9 m). The cable is defib-proof and reusable; follow facility protocol when cleaning it between patients. It is supplied one per bag.


When to Replace Your 5-Lead One-Piece ECG Cable

Replace the cable when a snap no longer holds on the electrode stud, when any lead or the main cable has a split, cracked, or kinked jacket, or when the monitor-end connector has bent pins or a damaged housing. Persistent lead-off messages, a noisy V lead, or a trace that flattens when the patient turns are other signs of a failing cable. A quick swap with a known-good cable helps biomedical staff isolate the problem.


Cross Reference and Interchange Part Numbers

M1977A is the OEM part this cable replaces, and OEM numbers M1986A and 989803160791 lead to the same cable. Aftermarket matches for this 5-lead snap cable are filed brand by brand in the Specifications tab, under Cross Reference / Interchange Part Numbers.


Why Source One-Piece ECG Cables from IPR Medical?

Five-lead snap cables are one of many accessories IPR Medical sells; the company buys, sells, repairs, and stocks parts for patient monitors and infusion pumps. In-house technicians handle IPR Medical’s repairs, and the company is certified to ISO 9001:2015 as an independent service organization. Reach us at 855-477-8866, or open our ECG cables and leadwires category for other options.

IPR Medical buys, sells, repairs, and stocks parts for one-piece 5-lead ECG cables and the patient monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.