GE Healthcare 2006644-001 Compatible SpO2 Adapter Cable for Nellcor Oxismart Sensors, 7.9 ft (2.4 m)
The GE Healthcare 2006644-001 compatible SpO2 adapter cable is a reusable, aftermarket replacement (not OEM) for GE’s Nellcor-compatible SpO2 extension cable, built to match the original’s fit, form, and function.
| SpO2 Technology | Nellcor Oxismart |
| Cable Length | 7.9 ft (2.4 m) |
| Lifecycle | Reusable |
Works with: Nellcor-equipped GE Dash 2500–5000, Solar 8000/8000M and i/9500, Tram 451 and TRAM x50SL modules, PDM module, Eagle, Responder, MAC-Lab, CARESCAPE B650/B850/V100, and Corometrics 120/128/250/259 monitors. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | SA-015-24 |
| OEM Reference | GE Healthcare 2006644-001 |
| Cable Type | SpO2 Adapter / Extension Cable |
| SpO2 Technology | Nellcor Oxismart |
| Cable Length | 7.9 ft (2.4 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Monitor must be configured with Nellcor SpO2.
| Manufacturer | Compatible Models |
| GE Healthcare / Marquette | Dash 2500, 3000, 4000, 5000; Dash Series |
| GE Healthcare / Marquette | Solar, Solar 8000, Solar 8000M; i/9500 |
| GE Healthcare / Marquette | Tram 451, TRAM 450SL, TRAM Modular, x50SL Series; PDM Module |
| GE Healthcare / Marquette | Eagle; Responder 2000, Responder 3000; MAC-Lab; Procare B40 |
| GE Healthcare CARESCAPE | B650, B850; V100, V100 with Nellcor Technology (no OxiMax) |
| GE Healthcare / Corometrics | 120, 128, 250, 250cx, 259 (with OxiMax Technology) |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| GE Healthcare | 2006644-001 |
| GE Healthcare / Marquette | 407252-002 |
| GE Healthcare / Marquette | E9004DE, E9004GE |
| AMC | CB-A400-1102A |
| Caremed | 131050021, SZ22-15 |
| Sage Services Group | E02-22M |
IPR Medical buys, sells, repairs, and stocks parts for GE Dash, Solar, CARESCAPE, and Corometrics equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Nellcor, GE Healthcare, Masimo, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the GE 2006644-001 Compatible SpO2 Adapter Cable?
The GE Healthcare 2006644-001 compatible SpO2 adapter cable is a reusable, aftermarket extension cable that connects Nellcor Oxismart-type pulse oximetry sensors to GE and Marquette monitors equipped with Nellcor SpO2. The patient’s sensor plugs into the end of this cable, which carries the signal back to the monitor for continuous oxygen saturation and pulse rate monitoring. Because the cable is separate from the sensor, facilities can replace sensors on their own and keep the reusable cable in service. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 2006644-001 cable. The OEM cable is 9.5 ft (2.9 m); this compatible version is 7.9 ft (2.4 m), so confirm the length suits your setup.
Compatible Monitor Models
This compatible cable is confirmed for use with Nellcor-equipped GE Marquette Dash 2500, 3000, 4000, and 5000 monitors, Solar 8000, 8000M, and i/9500 systems, Tram 451, TRAM 450SL, and TRAM modular x50SL-series modules, the PDM module, Eagle and Responder 2000 and 3000 monitors, MAC-Lab, and the Procare B40. It also fits GE CARESCAPE B650, B850, and V100 (Nellcor configuration without OxiMax) and Corometrics 120, 128, 250, 250cx, and 259 monitors. Many GE monitors were built with either Nellcor or Masimo SpO2, and the two technologies use different cables and sensors, so confirm your monitor’s SpO2 configuration before ordering.
Design and Construction
The cable runs 7.9 ft (2.4 m) from the monitor to the sensor connection, a comfortable reach for bedside, OR, and labor and delivery setups without a second extension. The sensor end accepts Nellcor Oxismart-compatible sensors in adult, pediatric, infant, and neonatal sizes. The cable is reusable after cleaning according to facility protocol and ships one per bag.
When to Replace Your GE Nellcor SpO2 Adapter Cable
SpO2 adapter cables flex constantly and are often pinched in bed rails or wrapped tightly around monitors. Replace the cable when the monitor shows “SpO2 sensor off,” “no sensor,” or cable fault messages with a known-good sensor, when readings or the pleth waveform drop out as the cable is moved, or when you find a cracked jacket, a loose sensor latch, or bent or recessed connector pins. Checking with a known-good sensor and a second cable quickly shows whether the cable, sensor, or monitor is at fault.
Cross Reference and Interchange Part Numbers
This compatible Nellcor Oxismart SpO2 adapter cable, IPR Medical SKU SA-015-24, cross-references to GE Healthcare part numbers 2006644-001, 407252-002, E9004DE, and E9004GE. It also interchanges with AMC CB-A400-1102A, Caremed 131050021 and SZ22-15, and Sage Services Group E02-22M. Materials managers and purchasing staff can use any of these numbers to confirm the match against existing inventory, work orders, or requisitions. For GE monitors with Masimo SpO2, IPR Medical also stocks the compatible GE 2027263-002 Masimo LNCS adapter cable.
Why Source SpO2 Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible SpO2 cables for both Nellcor and Masimo configurations of GE monitors, so biomedical teams can supply mixed fleets from one source at lower cost than OEM. Our team can help identify which SpO2 technology each of your monitors uses and support your GE equipment with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for GE Dash, Solar, CARESCAPE, and Corometrics equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Nellcor, GE Healthcare, Masimo, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.