IPR Medical

GE Healthcare Compatible SpO2 Adapter Cable, Masimo SET Monitor to Nellcor Oxismart Sensor, 9.8 ft (3.0 m)

$70.00

This GE Masimo to Nellcor SpO2 cable is a reusable, aftermarket adapter (not OEM) that lets GE monitors with Masimo SET SpO2 use Nellcor Oxismart sensors.

Monitor Technology Masimo SET
Sensor Compatibility Nellcor Oxismart
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable

Works with: Masimo-equipped GE CARESCAPE B450/B650/B850 and V100, Dinamap ProCare, Dash 2000–5000, Solar 7000/8000/i9500, Tram modules, Corometrics 250 series, and Datascope Accutorr, DPM, and Passport monitors. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.

IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: SA-015RB-30 Categories: , Tags: ,
Send In GE Healthcare Compatible SpO2 Adapter Cable, Masimo SET Monitor to Nellcor Oxismart Sensor, 9.8 ft (3.0 m) for Repair
Product Type Compatible Replacement (Aftermarket, Not OEM)
IPR Medical SKU SA-015RB-30
Cable Type SpO2 Adapter Cable (Masimo to Nellcor)
Monitor SpO2 Technology Masimo SET
Sensor Compatibility Nellcor Oxismart
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Packaging 1 per Bag

Compatible Monitor Models

Monitor must be configured with Masimo SET SpO2.

Manufacturer / Series Compatible Models
GE Healthcare CARESCAPE B450, B650, B850; V100, V100 with Masimo Technology
GE Healthcare / Dinamap ProCare 300, ProCare Auscultatory 400, ProCare with Masimo Pro 1000; Pro 300V2; ProSeries V2; V300
GE Healthcare / Marquette Dash 2000, 2500, 3000, 4000, 5000; Dash Series; Eagle, Eagle 1000; Procare B40
GE Healthcare / Marquette SOLAR, Solar 7000, 8000, 8000M; Solar Series; i/9500, i/9500 (Tram 451N5/851N5)
GE Healthcare / Marquette Tram 451, TRAM Modular, x50SL Series; PDM Module; CardioLab; MAC-Lab
GE Healthcare / Corometrics 128, 250, 250cx, 259; TRAM 450SL
Datascope Accutorr V, Accutorr 3, Accutorr 7, Accutorr Plus; DPM4, DPM6, DPM7; EPM4; MEC 12; MPM; Passport 2LT, Passport XG; PM 6800; T8; V12, V21; VS 800
Bitmos sat 800, sat 801, sat 805, sat 816, satPuls

Cross Reference / Interchange Part Numbers

GE and Masimo numbers identify the monitor-end interface. This cable’s sensor end accepts Nellcor Oxismart sensors.

Manufacturer / Supplier Part Number
GE Healthcare 2027263-002, 2017002-002
Masimo LNC-10-GE, M-LNC-GE10, M-LNC-10-GE, RD SET GE-12
Argo Biomedical ARSA-015RB-30
Medicable MCSA015RB30

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dash, Solar, and Dinamap patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Nellcor, GE Healthcare, Masimo, OxiSmart, SET, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the GE Masimo to Nellcor Oxismart SpO2 Adapter Cable?

This GE Healthcare compatible SpO2 adapter cable lets a GE monitor equipped with Masimo SET pulse oximetry use Nellcor Oxismart sensors. The monitor end connects to the GE Masimo SpO2 port, and the sensor end accepts Nellcor Oxismart-style sensors, so a facility can run Masimo-equipped GE monitors with the Nellcor sensors it already stocks. It is a compatible aftermarket replacement, not an original GE, Masimo, or Nellcor part.


Compatible Monitor Models

This compatible cable is confirmed for use with Masimo-equipped GE CARESCAPE B450, B650, B850, and V100 monitors and with Dinamap ProCare 300, ProCare Auscultatory 400, ProCare with Masimo Pro 1000, Pro 300V2, ProSeries V2, and V300 monitors. It also fits the Procare B40, Marquette Dash 2000 through 5000, Eagle and Eagle 1000, Solar 7000, 8000, 8000M, and i/9500 systems, Tram 451, TRAM modular, and x50SL-series modules, the PDM module, and CardioLab and MAC-Lab systems. Corometrics 128, 250, 250cx, and 259 monitors and the TRAM 450SL are supported, along with Masimo-equipped Datascope Accutorr, DPM, and Passport monitors and Bitmos sat-series oximeters. The monitor must be configured with Masimo SET SpO2. For GE monitors with Nellcor SpO2 built in, use a standard Nellcor adapter cable instead.


Design and Construction

The cable runs 9.8 ft (3.0 m), a longer reach that suits ICU, OR, and NICU setups where the monitor is boom- or wall-mounted away from the bedside. The monitor end matches the GE Masimo SET interface, and the sensor end accepts Nellcor Oxismart sensors. The cable is reusable after cleaning according to facility protocol and ships one per bag.


When to Replace Your GE Masimo to Nellcor SpO2 Adapter Cable

Replace the cable when the monitor shows “SpO2 sensor off,” “no cable,” or cable/sensor fault messages with a known-good Nellcor Oxismart sensor, when saturation or pleth readings drop out as the cable is moved, or when you find a cracked jacket, a loose sensor latch, or bent or corroded connector pins. Longer cables see more foot traffic and bed-rail pinching, so inspect them regularly. Swapping in a known-good cable and sensor quickly identifies which component is at fault.


Cross Reference and Interchange Part Numbers

This compatible Masimo-to-Nellcor Oxismart SpO2 adapter cable, IPR Medical SKU SA-015RB-30, references the GE Masimo SET interface family, including GE Healthcare 2027263-002 and 2017002-002 and Masimo LNC-10-GE, M-LNC-GE10, M-LNC-10-GE, and RD SET GE-12. It also corresponds to Argo Biomedical ARSA-015RB-30 and Medicable MCSA015RB30. Those GE and Masimo numbers identify the monitor connection this cable fits; unlike the OEM Masimo cables, this cable’s sensor end accepts Nellcor Oxismart sensors. To use Masimo LNCS sensors, see IPR Medical SKU SA-015RB-24LS (GE 2027263-002 compatible). For GE monitors with Nellcor SpO2 built in, see the compatible GE 2006644-001 (Oxismart) and 2021406-001 (OxiMax) cables.


Why Source SpO2 Cables from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible SpO2 cables for Masimo, Nellcor Oxismart, and Nellcor OxiMax configurations of GE monitors, including adapter cables that let one sensor line serve a mixed fleet. Our team can help identify each monitor’s SpO2 technology and support your GE equipment with in-house repair services.

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dash, Solar, and Dinamap patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Nellcor, GE Healthcare, Masimo, OxiSmart, SET, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.