IPR Medical

Nihon Kohden JP-920P Compatible IBP Adapter Cable, for Edwards Transducers, 13.1 ft (4.0 m)

$112.50

The Nihon Kohden JP-920P compatible IBP adapter cable (SKU IBP-NKB-EW40) is a reusable aftermarket replacement (not OEM) with a 13.1 ft (4.0 m) length, for use with Edwards transducers.

Product IBP Adapter Cable
Transducer Brand Edwards
Cable Length 13.1 ft (4.0 m)
Lifecycle Reusable
Replaces Nihon Kohden JP-920P

Works with: select Nihon Kohden BSM, Life Scope, PVM, and TEC models. See the Specifications tab for the full list. Browse more IBP cables and accessories.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors and IBP accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: IBP-NKB-EW40 Categories: , Tags: ,
Send In Nihon Kohden JP-920P Compatible IBP Adapter Cable, for Edwards Transducers, 13.1 ft (4.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) IBP-NKB-EW40
Replaces OEM Part Nihon Kohden JP-920P
Category Cables & Sensors > IBP
Product IBP Adapter Cable
Transducer Brand Edwards
Cable Length 13.1 ft (4.0 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Nihon Kohden BSM-73, BSM-73C, BSM-1101, BSM-1101K, BSM-1102, BSM-1102K, BSM-1700 Series, BSM-2000, BSM-2101, BSM-2102, BSM-2300, BSM-2300 Series, BSM-2300 with YJ 230P, BSM-2300C, BSM-2301, BSM-2301C, BSM-2303, BSM-2303C, BSM-2304, BSM-2351, BSM-2351C, BSM-2353, BSM-2353C, BSM-2354A, BSM-3000, BSM-3000 Series, BSM-3000 with AY 631P, BSM-3000 with AY 633P, BSM-3000 with AY 651P, BSM-3000 with AY 653P, BSM-3101, BSM-3500, BSM-3532, BSM-3552, BSM-3562, BSM-3700, BSM-3733, BSM-3753, BSM-3763, BSM-4100, BSM-4100 Series, BSM-4101, BSM-4101K, BSM-4102, BSM-4103, BSM-4103K, BSM-4104, BSM-4111, BSM-4111K, BSM-4112, BSM-4113, BSM-4113K, BSM-4114, BSM-5000 Series, BSM-5100, BSM-5100 Series, BSM-5100 with YJ 510P, BSM-5105, BSM-5105K, BSM-5135, BSM-5135K, BSM-6000 Series, BSM-6000 with AY 631P, BSM-6000 with AY 633P, BSM-6000 with AY 651P, BSM-6000 with AY 653P, BSM-6301, BSM-6301C, BSM-6301K, BSM-6311, BSM-6312, BSM-6313, BSM-6331, BSM-6332, BSM-6333, BSM-6501, BSM-6501C, BSM-6501K, BSM-6531, BSM-6532, BSM-6533, BSM-6571, BSM-6572, BSM-6573, BSM-6701, BSM-6701C, BSM-6701K, BSM-6731, BSM-6732, BSM-6733, BSM-6771, BSM-6772, BSM-6773, BSM-7100, BSM-7102A, BSM-7200, BSM-7201K, BSM-7211K, BSM-8200, BSM-8201, BSM-8300, BSM-8301, BSM-8301A, BSM-8302, BSM-8302A, BSM-8500, BSM-8500A, BSM-8502, BSM-8502A, BSM-8800, BSM-8800A, BSM-9100, BSM-9100 with AY 631P, BSM-9100 with AY 633P, BSM-9100 with AY 651P, BSM-9100 with AY 653P, BSM-9100 with YJ 671P, BSM-9101, BSM-9101K, BSM-9172, BSM-9173, BSM-9510, BSM-9510K, BSS 9800K, Life Scope J, Life Scope LC BSM-3101K, Life Scope TR, PVM 2703, TEC 8300, TEC 8321, TEC 8322, TEC 8332, TEC 8342, TEC 8352, Vismo PVM-2703

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Nihon Kohden JP-902P, JP-920P, JP-921P, K952, L901, L902
Edwards TWC-NKD1000
Unimed BC-NK2-ED

IPR Medical buys, sells, repairs, and stocks parts for invasive blood pressure cables for Nihon Kohden monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, Edwards, or any other manufacturer or supplier named on this page. Nihon Kohden, Edwards, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Nihon Kohden JP-920P Compatible IBP Adapter Cable?

The IPR Medical IBP-NKB-EW40 is a compatible aftermarket (not OEM) IBP adapter cable that replaces the Nihon Kohden JP-920P. Intended for use with Edwards transducers in invasive blood pressure (IBP) monitoring, this reusable cable is 13.1 ft (4.0 m) long.


Compatible Monitor Models

Select Nihon Kohden BSM models appear on the compatibility list for the IBP-NKB-EW40, with the BSM-2303, BSM-4100 Series, BSM-6501K, and BSM-9100 among them. The list also covers select Life Scope, PVM, and TEC models; the Life Scope J, Life Scope TR, and TEC 8322 are examples. For certain BSM models, a YJ or AY number is part of the listed entry, and the table preserves those entries in full. To make sure your monitor is covered, review the Compatible Monitor Models table on the Specifications tab first.


Design and Construction

The IBP-NKB-EW40 connects Edwards transducers to the compatible Nihon Kohden monitors in the table. The cable measures 13.1 ft (4.0 m) and ships one per bag. Clean it between patients as your facility protocol directs; it is reusable and can go back into use once it passes inspection.


When to Replace Your IBP Adapter Cable

Take the cable out of service if the outer jacket is split, crushed, or kinked, if the transducer connection feels loose or will not stay seated, or if the monitor connector has bent pins or a cracked shell. Dampened or intermittent pressure waveforms, zeroing errors, and pressure values that jump when the cable is handled are other common indicators of wear. Swapping in a known-good adapter cable with the same Edwards transducer and monitor is a quick way for biomedical staff to confirm the cause.


Cross Reference and Interchange Part Numbers

Along with the Nihon Kohden JP-920P, this compatible adapter cable cross-references to Nihon Kohden JP-902P, JP-921P, K952, L901, and L902. You will find the remaining interchange numbers, including those from other brands, in the Cross Reference / Interchange Part Numbers table on the Specifications tab.


Why Source IBP Cables from IPR Medical?

With its ISO 9001:2015 certification, IPR Medical works as an independent service organization that buys, sells, repairs, and stocks parts for patient monitors and infusion pumps. Monitor repair and testing are handled in-house by our own technicians, so we can help your team pair the right IBP adapter cable with your Nihon Kohden monitors and Edwards transducers and keep that equipment running. See more IBP cables and accessories, or call 855-477-8866 for ordering, repair, or parts support.

IPR Medical buys, sells, repairs, and stocks parts for invasive blood pressure cables for Nihon Kohden monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, Edwards, or any other manufacturer or supplier named on this page. Nihon Kohden, Edwards, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.