Masimo Compatible M-LNC-10 SpO2 Adapter Cable 2525, 9.8 ft (3.0 m), for M-LNCS Sensors
The IPR Medical SA-008RB-30ML is a compatible aftermarket replacement (not OEM) for the Masimo 2525 (M-LNC-10) SpO2 adapter cable. This reusable 9.8 ft (3.0 m) cable connects Masimo M-LNCS sensors to monitors equipped with Masimo SET technology.
| OEM Reference | Masimo 2525 (M-LNC-10) |
| Sensor Compatibility | Masimo M-LNCS Sensors |
| Monitor Connector | Masimo SET |
| Cable Length | 9.8 ft (3.0 m) |
Works with: Mindray/Datascope Passport XG, Passport 2LT, Accutorr Plus, V12, V21, Bitmos SAT 800 series, and more. See all compatible SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Aftermarket Replacement (Non-OEM) |
| IPR Medical SKU | SA-008RB-30ML |
| OEM Reference | Masimo 2525 (M-LNC-10) |
| Cable Type | SpO2 Patient / Adapter Cable |
| Monitor Connector | Masimo SET |
| Sensor Compatibility | Masimo M-LNCS Sensors |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Device must have a Masimo SET SpO2 port and use M-LNCS sensors.
| Manufacturer | Compatible Models |
| Mindray / Datascope | Accutorr V, Accutorr Plus, EPM4, Passport 2LT, Passport XG, T8, V12, V21; Accutorr Plus, Passport 2, Passport 2LT, and Passport XG with Masimo Rainbow Option |
| Bitmos | SAT 800, SAT 801, SAT 805, SAT 816, satPuls |
| Atom | V-2100G |
| Comen | C60 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2525 (M-LNC-10) |
| Draeger | MP02989 |
| Comen | 040-000204-00 |
| IPR Medical | SA-008RB-30ML |
IPR Medical buys, sells, repairs, and stocks parts for Masimo SET pulse oximetry equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Masimo Compatible M-LNC-10 SpO2 Adapter Cable 2525?
The IPR Medical SA-008RB-30ML is a compatible aftermarket replacement for the Masimo 2525 (M-LNC-10) SpO2 adapter cable. It is not an OEM product. This 9.8 ft (3.0 m) reusable patient cable connects Masimo M-LNCS pulse oximetry sensors to monitors equipped with Masimo SET technology. It is designed to match the original 2525 cable in fit, form, and function.
Compatible Monitor Models
This cable is compatible with the following Masimo SET-equipped Mindray/Datascope monitors: Accutorr V, Accutorr Plus, EPM4, Passport 2LT, Passport XG, T8, V12, and V21. It also fits Accutorr Plus, Passport 2, Passport 2LT, and Passport XG monitors configured with the Masimo rainbow option. It is also compatible with the Bitmos SAT 800, SAT 801, SAT 805, SAT 816, and satPuls, the Atom V-2100G, and the Comen C60. Before ordering, confirm that your device has a Masimo SET SpO2 port and uses M-LNCS sensors.
Design and Construction
The cable has a Masimo SET connector on the monitor end and an M-LNCS sensor connector on the patient end, joined by a flexible, shielded 9.8 ft (3.0 m) cable. The M-LNCS interface is a different connector from the standard LNCS interface. This cable will not accept standard LNCS, LNOP, or RD SET sensors. The longer length gives clinicians room to work around the bed, OR table, or stretcher without pulling on the sensor or the monitor port. The cable is reusable and supplied one per bag.
When to Replace Your M-LNC-10 SpO2 Adapter Cable
Replace the cable if you see intermittent or dropped SpO2 readings, “sensor off” or “no cable” alarms with a known-good sensor attached, or readings that drop out when the cable is moved. Cracked or loose connector housings, bent or recessed pins, and a cut or kinked jacket are also signs it should be replaced. Longer patient cables are more prone to being rolled over, pinched in bed rails, and kinked. Biomedical technicians can confirm a cable fault by swapping in a known-good cable and sensor. If readings return to normal, the cable should be retired. Keeping a spare M-LNC-10 cable on hand reduces monitor downtime in the OR, ICU, and med-surg units.
Cross Reference and Interchange Part Numbers
The IPR Medical SA-008RB-30ML cross-references to Masimo 2525 (M-LNC-10), Draeger MP02989 and Comen 040-000204-00. This cable is for M-LNCS sensors only. If you need a shorter cable, choose the compatible M-LNC-4, IPR Medical SKU SA-008RB-12ML. If your facility uses standard LNCS sensors on a gray Masimo SET port, choose the compatible LNC-10 cable, IPR Medical SKU SA-008RB-30LS. If your device has a red Masimo rainbow SET connector and uses M-LNCS sensors, choose the compatible RC series cables, IPR Medical SKU SA-009RB-03ML or SA-009RB-12ML.
Why Source SpO2 Adapter Cables from IPR Medical?
IPR Medical is an ISO 9001:2015 certified supplier of patient monitoring accessories, infusion pump parts, and medical equipment. Our team works with biomedical departments, materials managers, and clinical staff every day to find the right compatible cables and sensors quickly and at a fraction of OEM cost. Beyond accessories, IPR Medical buys, sells, and repairs patient monitoring equipment in-house, and stocks a deep inventory of replacement parts.
IPR Medical buys, sells, repairs, and stocks parts for Masimo SET pulse oximetry equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews