Nellcor D-YSPD Compatible Pediatric Finger Clip SpO2 Sensor, OxiMax, Hard Shell, 3.3 ft (1.0 m)
The Nellcor D-YSPD compatible pediatric finger clip SpO2 sensor (SKU SS-001XC-PF10) is a reusable aftermarket replacement (not OEM) with a hard shell finger clip and a 3.3 ft (1.0 m) cable, for use with Nellcor OxiMax technology.
| Sensor Type | Hard Shell Finger Clip |
| Patient Size | Pediatric |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 3.3 ft (1.0 m) |
| Lifecycle | Reusable |
| Replaces | Nellcor D-YSPD |
Works with: select Nellcor, GE Healthcare, Mindray / Datascope, Welch Allyn, and Nihon Kohden models, plus other brands. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-001XC-PF10 |
| Replaces OEM Part | Nellcor D-YSPD |
| Category | Cables & Sensors > SpO2 |
| Sensor Type | Hard Shell Finger Clip |
| Patient Size | Pediatric |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 3.3 ft (1.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Artema S&W | Diascope |
| Baxter | Explorer, Monarch |
| Biolight | M8500, M9500, Q3, Q5, Q7, Q Series |
| Biosys | BPM-200, Sentry |
| Cardell | 8019-001, 8019-002, 8019-003, 9402, 9403, 9405, 9500 Series, 9500HD, MAX-12 Duo HD, Touch |
| CAS Med | 511, 740 |
| Charmcare | CX100 |
| Criticare / CSI | 506DNV3, 506DNVP3, 506LN3, 506LNP3, 506LNT3, 506LNTP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
| Datex-Ohmeda | AS/3, Cardiocap/5, enGuard CM5 |
| Digicare | LW600 |
| Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Narkomed 6400 |
| DRE | ASM 5000, Waveline, Waveline EZ MAX, Waveline Plus |
| Edan | Elite V8, iM3, iM20, iM50 |
| Fukuda Denshi | Dynascope DS-7100, Dynascope DS-8100, LX-7230N |
| GE Healthcare | 129, 188, 9710, 9720 Plus, Compact, M-NSAT Modules, MPS, Pro 400, Pro Series, ProCare, Select |
| GE Healthcare / Corometrics | 250cx |
| GE Healthcare / Critikon Dinamap | B105M, B105P, B125M, B125P, B155M, Carescape B650, Carescape V100, Compact DINAMAP MPS, Compact S, Compact TS, E-NSAT, Pro 200, Pro 300, Pro 1000, Pro 1000 V3, Pro Series V2, ProCare 200, ProCare 400, ProCare Auscultatory 400 |
| GE Healthcare / Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, i/9500, PDM Module, Procare B40, Solar 8000, Solar 8000M, Tram 451 |
| Goldway | Vet 420A, Vet 600A |
| Guthan | 1000 |
| Invivo | Escort II OPT30, MDE Escort Prism, Prism |
| Ivy Biomedical | 405P, 405T, 450C, 700, CM5 |
| Mediana | M20 |
| Medtronic / Covidien | Capnostream 35 (PM35MN) |
| Mindray / Datascope | Accutorr Plus, Accutorr V, BeneHeart D3, BeneView T1, BeneVision ePM 10M, BeneVision ePM 12, BeneVision ePM 12M, BeneVision ePM 15, BeneVision N1, BeneVision N12, BeneVision N12 Neo, BeneVision N15, BeneVision N17, BeneVision N22, BeneVision VS-900, cPM 8, cPM 12, DPM4, DPM5, DPM6, DPM7, Duo, ePM 10A, Expert, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM12VET, iPM-9800, MEC-1200Vet, Passport 2, Passport 8, Passport 12, Passport V, Passport XG, PM-9000Vet, Spectrum, Spectrum OR, Trio, V12, V-Series, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C |
| Mortara | Surveyor S12/S19 |
| Nellcor | N-10, N-20, N-30, N-45, N-65, N-85, N-100, N-180, N-190, N-200, N-390, N-395, N-560, N-595, N-600, N-600x, N-3000, N-6000, NPB-40, NPB-70, NPB-75, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3900, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-4000, NPB-4000C, PM10N, PM100N, PM1000N, Symphony N-3000 |
| Nihon Kohden | AY-651P, AY-653P, BSM-1700 Life Scope PT, BSM-1753, BSM-2300, BSM-2304A, BSM-3552, BSM-3572, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100, BSM-6000 Series, BSM-6301A, BSM-6310K, BSM-6501K, BSM-6701K, Life Scope TR |
| Nonin | 8500, 8604, 9700 |
| Omron / Colin | BP-88, BP-88S, BP-306, BP-508, BP-808, BP-S510, Press-Mate, T105NXM |
| Oridion | Capnostream 20 |
| Philips | FM20, FM30, FM40, FM50, Heartstream XL, IntelliVue MP2, IntelliVue MP30, IntelliVue MP70, IntelliVue MX400, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, Prodigy, SureSigns VS2, SureSigns VS3, VS1 |
| Physio-Control | Lifepak 12, Lifepak 15 |
| Siemens | SC8000 |
| Skanray | Star 55 |
| Smiths Medical / BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Advisor S#155, Autocorr, Mini Torr, Mini Torr Plus, Spectro2 10, Spectro2 20, Spectro2 30 |
| Spacelabs | Telemetry Transmitter (96281), Ultraview SL, Ultraview SL 2700 |
| Suntech | 247B |
| Waltvick | Humyzin |
| Welch Allyn | 42NT0-E1 LXi, 52N Series, 53N0P, 53NT0, 53NTP, 64N Series, 65N Series, 67N Series, 68N Series, 71WT-B Connex Spot, 73C Series, 73WT-B Connex Spot, 74C Series, 1500, 4400 44WT-B, 6000 Series, 901058, Atlas 6200 Series, Connex 6000 Series, Connex Vital Signs, Encore 202EL, Propaq 106-EL, Propaq 202-EL, Propaq 204-EL, Propaq 206-EL, Propaq 244, Propaq CS, Propaq LT, Series 420, Spot Vital Signs 42MOB, Spot Vital Signs 42NOB, Spot Vital Signs 42NTB-E1 |
| Mindray / Datascope (with Nellcor SpO2 Option) | Accutorr Plus, Expert, Passport 5L, Passport EL, Passport XG |
| PaceTech (with Nellcor SpO2 Option) | Vitalmax 800 Series (black) |
| Welch Allyn (with Nellcor SpO2 Option) | Atlas |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Nellcor (Covidien) | D-YSPD |
| Mediaid | CST062-3120 |
| Praymed | PSB0026-S |
| Unimed | U103-01P |
IPR Medical buys, sells, repairs, and stocks parts for SpO2 sensors and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Nellcor D-YSPD Compatible Pediatric SpO2 Sensor?
The IPR Medical SS-001XC-PF10 is a compatible aftermarket (not OEM) pediatric finger clip SpO2 sensor that replaces the Nellcor D-YSPD. It is a reusable hard shell sensor intended for use with Nellcor OxiMax technology, and it comes with a 3.3 ft (1.0 m) cable.
Compatible Monitor Models
The compatibility listings for this pediatric sensor cover select Nellcor models such as the N-395, N-600x, and NPB-295, select GE Healthcare Dinamap, Dash, Solar, and Carescape monitors, select Mindray and Datascope Passport, Spectrum, DPM, iMEC, and BeneVision models, and select Welch Allyn, Nihon Kohden, Smiths Medical BCI, Criticare, Draeger, Edan, and Physio-Control Lifepak models, as well as models from the other brands shown in the table. Some Mindray / Datascope, PaceTech, and Welch Allyn models are listed for use with the Nellcor SpO2 option, and those configurations sit in their own rows. Refer to the Compatible Monitor Models table on the Specifications tab for every listed model, and confirm your monitor and SpO2 option before ordering.
Design and Construction
The SS-001XC-PF10 has a hard shell finger clip housing sized for pediatric patients and is intended for use with Nellcor OxiMax SpO2 technology. Its cable is 3.3 ft (1.0 m) long, and each sensor is packaged one per bag. The sensor is reusable, so it can be cleaned between patients according to facility protocol and returned to service while it continues to pass inspection.
When to Replace Your Pediatric SpO2 Sensor
Pull the sensor from service if the finger clip housing is cracked, the clip no longer stays closed on the finger, the cable jacket is nicked, split, or kinked, or the connector has bent or damaged pins. Readings that fluctuate or drop out, repeated sensor-off or poor-signal alarms, and values that change when the cable is flexed are also signs of a worn sensor. Swapping in a known-good sensor on the same monitor lets biomedical staff confirm whether the sensor is at fault.
Cross Reference and Interchange Part Numbers
This compatible sensor replaces the Nellcor D-YSPD. Other interchange numbers are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our technicians repair monitors in-house, which lets our team help you match pediatric SpO2 sensors to the monitors you have in service. Shop our SpO2 sensors and cables, or call 855-477-8866 for help with an order, a repair, or parts.
IPR Medical buys, sells, repairs, and stocks parts for SpO2 sensors and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews