Nellcor SC-PR Compatible Pediatric/Infant Disposable SpO2 Sensor, Non-Adhesive Foam, OxiMax, Box of 24, 3.0 ft (0.9 m)
The Nellcor SC-PR compatible pediatric/infant non-adhesive foam SpO2 sensor (SKU SSD-001XC-S09PI) is a disposable aftermarket replacement (not OEM) with a 3.0 ft (0.9 m) cable, supplied 24 per box, for use with Nellcor OxiMax technology.
| Sensor Type | Non-Adhesive Foam |
| Patient Size | Pediatric/Infant |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 3.0 ft (0.9 m) |
| Lifecycle | Disposable |
| Packaging | Box of 24 |
| Replaces | Nellcor SC-PR |
Works with: select Nellcor, GE Healthcare, Mindray / Datascope, Welch Allyn, and Smiths Medical / BCI models, plus other brands. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SSD-001XC-S09PI |
| Replaces OEM Part | Nellcor SC-PR |
| Category | Cables & Sensors > SpO2 |
| Sensor Type | Non-Adhesive Foam |
| Patient Size | Pediatric/Infant |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 3.0 ft (0.9 m) |
| Lifecycle | Disposable |
| Packaging | 24 per box |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Artema S&W | Diascope |
| Baxter | Explorer, Monarch |
| Biolight | M8500, M9500, Q3 |
| Bionics | BPM-200 |
| Bird | Sentry |
| Cardell | 9403, 9405, 9500 Series, 9500HD, MAX-12 Duo HD |
| Charmcare | CX100 |
| Criticare / CSI | 506DNV3, 506DNVP3, 506LN3, 506LNP3, 506LNT3, 506LNTP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
| Datex-Ohmeda | Cardiocap/5, enGuard CM5 |
| Digicare | LW600 |
| Draeger | Narkomed 6400 |
| DRE | ASM 5000, Waveline, Waveline EZ MAX, Waveline Plus |
| Edan | Elite V8, iM3, iM50 |
| Fukuda Denshi | Dynascope DS-7100, LX-7230N |
| GE Healthcare | 129, 188, 511, 9710, 9720 Plus, Carescape B650, Carescape V100, Compact, Compact DINAMAP MPS, E-NSAT, M-NSAT Modules, MPS, Pro 200, Pro 300, Pro 400, Pro 1000, Pro 1000 V3, Pro Series, Pro Series V2, ProCare, ProCare 200, ProCare 400, ProCare Auscultatory 400, Select |
| GE Healthcare / Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, i/9500, PDM Module, Procare B40, Solar 8000, Solar 8000M, Tram 451 |
| Goldway | Vet 420A, Vet 600A |
| Guthan | 1000 |
| Invivo | Escort II OPT30, MDE Escort Prism, Prism |
| Ivy Biomedical | 405P, 405T, 450C, 700, CM5 |
| Mindray / Datascope | Accutorr Plus, BeneHeart D3, BeneView T1, BeneVision ePM 10M, BeneVision ePM 12, BeneVision ePM 12M, BeneVision ePM 15, BeneVision N1, BeneVision N12, BeneVision N12 Neo, BeneVision N15, BeneVision N17, BeneVision N22, BeneVision VS-900, DPM5, DPM6, DPM7, Duo, Expert, MEC-1200Vet, Passport 2, Passport 8, Passport 12, Passport V, Passport XG, PM-9000Vet, Spectrum, Spectrum OR, Trio, V12, V-Series |
| Nellcor | N-10, N-20, N-30, N-45, N-65, N-85, N-100, N-180, N-190, N-200, N-390, N-395, N-560, N-595, N-600, N-600x, N-3000, N-6000, NPB-40, NPB-70, NPB-75, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3900, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-4000, NPB-4000C, PM10N, PM100N, Symphony N-3000 |
| Nihon Kohden | BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100 |
| Nonin | 8500, 8604, 9700 |
| Omron / Colin | BP-88, BP-88S, BP-306, BP-508, BP-808, BP-S510, Press-Mate, T105NXM |
| Oridion | Capnostream 20 |
| Philips | Heartstream XL, IntelliVue MP2, IntelliVue MP70, IntelliVue MX450, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, Prodigy, SureSigns VS2, SureSigns VS3, VS1 |
| Physio-Control | Lifepak 12, Lifepak 15 |
| Smiths Medical / BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Advisor S#155, Autocorr, Mini Torr, Mini Torr Plus |
| Suntech | 247B |
| Waltvick | Humyzin |
| Welch Allyn | 42NT0-E1 LXi, 53N0P, 53NT0, 53NTP, 1500, 6000 Series, Atlas 6200 Series, Encore 202EL, Propaq 106-EL, Propaq 202-EL, Propaq 204-EL, Propaq 206-EL, Propaq 244, Propaq CS, Propaq LT, Series 420, Spot Vital Signs 42NTB-E1 |
| Datex-Ohmeda (with Nellcor SpO2 Option) | Vitalmax 800 Series (black) |
| Mindray / Datascope (with Nellcor SpO2 Option) | Accutorr Plus, Expert, Passport 5L, Passport EL, Passport XG |
| Welch Allyn (with Nellcor SpO2 Option) | Atlas |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Nellcor (Covidien) | SC-PR |
IPR Medical buys, sells, repairs, and stocks parts for pediatric and infant SpO2 sensors and the monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Nellcor SC-PR Compatible Pediatric/Infant Disposable SpO2 Sensor?
The IPR Medical SSD-001XC-S09PI is a compatible aftermarket (not OEM) pediatric/infant non-adhesive foam SpO2 sensor that replaces the Nellcor SC-PR. Sized for pediatric and infant patients, this disposable sensor is designed for use with Nellcor OxiMax technology and has a 3.0 ft (0.9 m) cable; it is sold 24 per box.
Compatible Monitor Models
Compatibility listings for this pediatric/infant sensor name select Nellcor models such as the N-85, N-390, and NPB-3900, select GE Healthcare Pro Series, Carescape, Dash, and Solar models, and select Mindray / Datascope DPM, Passport, Trio, and BeneVision models. Select Welch Allyn Propaq, Omron / Colin, Smiths Medical / BCI, Edan, Biolight, and Physio-Control Lifepak models are listed too, as well as models from the other brands in the table. Some Datex-Ohmeda, Mindray / Datascope, and Welch Allyn models are listed for use with the Nellcor SpO2 option; those configurations appear in separate rows. Use the Compatible Monitor Models table on the Specifications tab to verify your monitor and SpO2 option.
Design and Construction
The SSD-001XC-S09PI is a non-adhesive foam sensor sized for pediatric and infant patients and intended for use with Nellcor OxiMax SpO2 technology. It has a 3.0 ft (0.9 m) cable, with 24 sensors in each box. The sensor is disposable; once used, discard it per facility protocol.
When to Replace Your Pediatric/Infant Disposable SpO2 Sensor
Replace the sensor whenever the fit fails and it can no longer be kept securely in position, when it is soiled or damaged, or in keeping with facility protocol. SpO2 dropouts, recurring sensor-off or weak-signal alarms, and readings that change with cable movement are other signs that a fresh sensor is needed. Should the symptoms continue with a new sensor, biomedical staff can evaluate the monitor and its SpO2 connection.
Cross Reference and Interchange Part Numbers
This compatible sensor replaces the Nellcor SC-PR, the interchange number listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source SpO2 Sensors from IPR Medical?
As an ISO 9001:2015-certified independent service organization, IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our technicians repair monitors in-house, which means our team can help you pick pediatric and infant SpO2 sensors that suit your monitors. Browse more SpO2 sensors and cables, or call 855-477-8866 for orders, repairs, or parts support.
IPR Medical buys, sells, repairs, and stocks parts for pediatric and infant SpO2 sensors and the monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.