Masimo 2652 (DBI-dc8) Compatible Adult Soft Tip SpO2 Sensor, 14-Pin Direct-Connect, Reusable, 9.8 ft (3.0 m)
The Masimo 2652 (DBI-dc8) compatible SpO2 sensor (SKU SS-008RB-AS30) is a reusable, aftermarket replacement (not OEM) adult soft tip sensor that plugs directly into 14-pin Masimo SET monitors, with no patient cable required. It is built to match the original’s fit, form, and function.
| Sensor Type | Soft Tip (Finger) |
| Patient Size | Adult, >66 lbs (>30 kg) |
| Connector | 14-Pin Masimo SET, Direct-Connect |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Replaces | Masimo 2652 (DBI-dc8), Physio-Control 11171-000051, Unimed U410S-15R, Praymed PSC0020-L |
Works with: Masimo SET-equipped Mindray/Datascope Passport, Spectrum, Accutorr, and V-Series monitors, GE Dinamap ProCare and ProSeries, Zoll E, M, and R Series, Invivo Escort II, and more. See the Specifications tab for the full list. Prefer a spring clip? Ask about our 1969 adult clip version. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-008RB-AS30 |
| Replaces OEM Part | Masimo 2652 (DBI-dc8) |
| Category | Reusable SpO2 Sensor |
| Sensor Type | Soft Tip (Finger) |
| Patient Size | Adult |
| Patient Weight Range | >66 lbs (>30 kg) |
| Cable Length | 9.8 ft (3.0 m) |
| Connector | 14-Pin Masimo SET, Direct-Connect (No Patient Cable Required) |
| SpO2 Technology | Masimo SET |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Mindray / Datascope | Accutorr V, Accutorr Plus, Accutorr Plus with Masimo Rainbow Option, EPM4, Passport 2, Passport 2 with Masimo Rainbow Option, Passport 2LT, Passport 2LT with Masimo Rainbow Option, Passport Duo, Passport Trio, Passport V, Passport XG, Passport XG with Masimo Rainbow Option, Spectrum, Spectrum OR, T8, V12, V21 |
| GE Healthcare (Dinamap) | ProCare with Masimo (Pro 1000, Pro 300V2, Pro 400V2), ProCare 300, ProCare Auscultatory 400, ProSeries V2, V300 |
| Zoll | E Series, M Series, R Series |
| Invivo | Escort II OPT30 Prism, T8 |
| CASMed | 740 |
| Respironics | Alice 5 |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| Comen | C60 |
| Atom | V-2100G |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2652 (DBI-dc8) |
| Physio-Control (Stryker) | 11171-000051 |
| Praymed | PSC0020-L, PSC0204-L |
| Unimed | U410S-15R |
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2652 DBI-dc8 SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Compatible Masimo 2652 DBI-dc8 SpO2 Sensor?
The Masimo 2652 (DBI-dc8) compatible SpO2 sensor (IPR SKU SS-008RB-AS30) is a reusable adult soft tip finger sensor that plugs directly into monitors with a 14-pin Masimo SET SpO2 port. It is a compatible aftermarket replacement, not an OEM Masimo product, built to match the fit, form, and function of the original. Because the 9.8 ft (3.0 m) cable runs straight from the sensor to the monitor, no separate patient cable is needed, which simplifies setup and removes a common point of failure. Direct-connect sensors are widely used on Masimo SET-equipped Mindray/Datascope Passport and Spectrum monitors and GE Dinamap ProCare vital signs monitors.
Compatible Monitor Models
This compatible sensor works with Masimo SET-equipped Mindray and Datascope monitors including the Accutorr V, Accutorr Plus, EPM4, Passport 2, Passport 2LT, Passport V, Passport XG, Passport Duo, Passport Trio, Spectrum, Spectrum OR, T8, V12, and V21, including Masimo Rainbow Option configurations of the Accutorr Plus, Passport 2, Passport 2LT, and Passport XG. It is also compatible with GE Dinamap ProCare with Masimo (Pro 1000, Pro 300V2, Pro 400V2), ProCare 300, ProCare Auscultatory 400, ProSeries V2, and V300; Zoll E, M, and R Series; Invivo Escort II OPT30 Prism and T8; CASMed 740; Respironics Alice 5; Bitmos sat 800, 801, 805, 816, and satPuls; Comen C60; and Atom V-2100G. Confirm that your device has a 14-pin Masimo SET SpO2 input before ordering.
Design and Construction
The soft tip design wraps the fingertip without the spring pressure of a hard shell clip. That improves comfort during extended monitoring, reduces pressure points on fragile skin, and helps the sensor stay in place on restless patients. It is sized for adult patients weighing more than 66 lbs (30 kg). The 9.8 ft (3.0 m) cable gives enough reach to run from a pole- or cart-mounted monitor to the patient without an extension. The sensor is reusable and supplied one per bag.
When to Replace Your 2652 DBI-dc8 SpO2 Sensor
Because a direct-connect sensor’s cable runs all the way to the monitor, the cable takes more handling than a short sensor. Wear shows up at the soft tip, along the cable, and at the monitor connector. Replace the sensor when the soft tip material is torn, stretched, or hardened and no longer holds the finger securely, the emitter or detector windows are scratched or discolored, the connector is cracked or has bent pins, or the cable shows cuts, kinks, or exposed shielding. Persistent “sensor off” alarms or readings that drop out when the cable is moved also point to a failing sensor. If a sensor fails to read on a monitor that passes self-test, try a known-good sensor to isolate the fault quickly.
Cross Reference and Interchange Part Numbers
This compatible sensor cross-references to Masimo 2652 (DBI-dc8) and Physio-Control 11171-000051. Aftermarket interchange numbers include Praymed PSC0020-L and PSC0204-L and Unimed U410S-15R. The OEM 2652 has an 8 ft cable; this compatible version uses a 9.8 ft (3.0 m) cable with the same sensor and connector configuration.
Why Source Masimo-Compatible SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment. Compatible reusable SpO2 sensors give biomedical departments, clinics, and materials managers a cost-effective way to keep Masimo SET-equipped monitors in service without paying OEM pricing. Our team can confirm fit against your monitor model before you order, and we also offer in-house repair services, replacement parts, and refurbished equipment, so you can source accessories and service from a single partner.
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2652 DBI-dc8 SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.