Masimo LNC-10 (1814) Compatible LNCS SpO2 Patient Cable, Reusable, 9.8 ft (3.0 m)
The Masimo LNC-10 SpO2 cable 1814 compatible replacement is a reusable, aftermarket 9.8 ft LNCS patient cable (not OEM) that connects Masimo LNCS sensors to Masimo SET oximeters, monitors, and defibrillators, built to OEM fit, form, and function.
| SpO2 Technology | Masimo LNCS |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
Works with: Masimo Radical-7, Rad-5/8/9/57/87, Physio-Control Lifepak 11/12/15/20, Zoll E/M/R Series, Masimo-equipped Datascope and Mindray Passport, Accutorr, and Spectrum, GE Dinamap ProCare, and Welch Allyn Spot Vital Signs and Connex Spot. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | SA-008RB-30LS |
| OEM Reference | Masimo 1814 (LNC-10) |
| Cable Type | SpO2 Patient / Adapter Cable |
| SpO2 Technology | Masimo LNCS |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Device must be configured with Masimo SET SpO2.
| Manufacturer | Compatible Models |
| Masimo | Radical, Radical-7; Rad-5, Rad-5v, Rad-8, Rad-9, Rad-57, Rad-87; Pronto-7; Bitmos 901 M, 901 ML |
| Physio-Control | Lifepak 11, 12, 15, 20, 20E |
| Zoll | E Series, M Series, R Series |
| Datascope | Accutorr V, Accutorr Plus (incl. Masimo Rainbow Option); EPM4; Passport 2 (Masimo Rainbow Option), Passport 2LT, Passport XG; T8; V12, V21 |
| Mindray (Masimo Option) | Accutorr V; Duo; Passport 2, Passport V; Spectrum, Spectrum OR; Trio; V12, V21 |
| GE Healthcare / Dinamap | ProCare with Masimo Pro 1000; Pro 300V2, Pro 400V2; ProCare 300, ProCare Auscultatory 400; ProSeries V2; V300; Corometrics 250cx |
| Welch Allyn | Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi, 45NE0-E1 LX; 53S00, 53S0P, 53ST0, 53STP; 73ME-B, 73MT-B, 74ME-B, 74MT-B, 74MX-B; 75ME-B, 75MT-B Connex Spot, 75MX-B; Propaq CS |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| Other | Atom V-2100G; CAS Med 740; Comen C60; DRE Waveline; Invivo Escort II OPT30 Prism; Respironics Alice 5 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 1814 (LNC-10) |
| GE Healthcare / Marquette | 2027263-001 |
| Draeger | MP00797 |
| DRE | P02054 |
| Mindray | 0012-00-1599, 0012-00-1653 |
| Physio-Control | 11171-000016 |
| Zoll | 8000-0293 |
| Pacific Medical | NXMA100 |
| Tenacore | TCEO-0208-0622, TE1417 |
| Unimed | U708M-15R, U710M-15R |
IPR Medical buys, sells, repairs, and stocks parts for Masimo-equipped patient monitors, pulse oximeters, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Masimo LNC-10 Compatible LNCS SpO2 Patient Cable?
The Masimo LNC-10 (1814) compatible SpO2 patient cable is a reusable, aftermarket adapter cable that connects Masimo LNCS pulse oximetry sensors to Masimo SET oximeters and to monitors and defibrillators from other manufacturers that use the Masimo SET patient cable connector. At 9.8 ft (3.0 m), it matches the 10 ft length of the OEM LNC-10. It is a compatible replacement, not an original Masimo part, and it is built to OEM fit, form, and function.
Compatible Monitor Models
This compatible cable is confirmed for use with Masimo Radical, Radical-7, Rad-5, Rad-5v, Rad-8, Rad-9, Rad-57, Rad-87, and Pronto-7 devices, Physio-Control Lifepak 11, 12, 15, 20, and 20E defibrillator/monitors, and Zoll E, M, and R Series defibrillators. It also fits Masimo-equipped Datascope and Mindray Accutorr, Passport, Spectrum, Duo, Trio, and V-series monitors, GE Dinamap ProCare, ProSeries, and V300 monitors, the Corometrics 250cx, Welch Allyn Spot Vital Signs, Connex Spot, Propaq CS, and 53- and 7x-series monitors, and Bitmos, Atom, Comen, CAS Med, DRE, Invivo, and Respironics devices. The monitor must be configured with Masimo SET SpO2; see the Specifications tab for the full model list.
Design and Construction
The 9.8 ft (3.0 m) cable gives extra reach for ICU, OR, and emergency department setups where the monitor sits on a boom, wall mount, or crash cart away from the patient. The sensor end accepts Masimo LNCS sensors in adult, pediatric, infant, and neonatal sizes, in both reusable and single-patient-use styles. The cable is reusable after cleaning according to facility protocol and ships one per bag.
When to Replace Your Masimo LNCS Patient Cable
Replace the cable when the monitor shows “SpO2 sensor off,” “no cable,” “replace cable,” or cable/sensor fault messages with a known-good LNCS sensor, when saturation or pleth readings drop out as the cable is moved, or when you find a cracked jacket, a loose sensor latch, or bent or corroded connector pins. Longer cables are more likely to be pinched in bed rails or stepped on, and cables on defibrillators and transport monitors are flexed and stowed often, so inspect the jacket and strain reliefs during routine checks.
Cross Reference and Interchange Part Numbers
This compatible Masimo LNCS patient cable, IPR Medical SKU SA-008RB-30LS, cross-references to Masimo 1814 (LNC-10), GE Healthcare / Marquette 2027263-001, Draeger MP00797, DRE P02054, Mindray 0012-00-1599 and 0012-00-1653, Physio-Control 11171-000016, and Zoll 8000-0293. It also interchanges with Pacific Medical NXMA100, Tenacore TCEO-0208-0622 and TE1417, and Unimed U708M-15R and U710M-15R. For a shorter cable, IPR Medical also stocks a 7.9 ft (2.4 m) version, SKU SA-008RB-24LS. For GE monitors with Masimo SET and a GE-style SpO2 connector, see the compatible GE 2027263-002 cable, SKU SA-015RB-24LS.
Why Source SpO2 Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible Masimo, Nellcor, and TruSignal SpO2 cables and sensors for multi-brand fleets of monitors, oximeters, and defibrillators, so biomedical teams can standardize sourcing at lower cost than OEM. Our team can help identify each device’s SpO2 technology and connector and support your equipment with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for Masimo-equipped patient monitors, pulse oximeters, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.