Masimo Red LNC-14 (2057) Compatible SpO2 Patient Cable for LNCS Sensors, Reusable, 11.8 ft (3.6 m)
The Masimo Red LNC-14 SpO2 cable 2057 compatible replacement is a reusable, aftermarket 11.8 ft cable (not OEM) that connects Masimo LNCS sensors to rainbow SET devices with the red 20-pin connector, built to OEM fit, form, and function.
| Monitor Connector | Masimo Red (Rainbow SET), 20-Pin |
| Sensor Compatibility | Masimo LNCS |
| Cable Length | 11.8 ft (3.6 m) |
| Lifecycle | Reusable |
Works with: Masimo Radical-7, Rad-97, Rad-87, Rad-8, Rad-57 family, and Pronto/Pronto-7, Physio-Control Lifepak 15, Zoll X Series, and Comen K12 Pro. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | SA-009RB-36LS |
| OEM Reference | Masimo 2057 (Red LNC-14) |
| Cable Type | SpO2 Patient / Adapter Cable |
| Monitor Connector | Masimo Red (Rainbow SET), 20-Pin |
| Sensor Compatibility | Masimo LNCS |
| Cable Length | 11.8 ft (3.6 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Device must have a red Masimo rainbow SET patient cable connector.
| Manufacturer | Compatible Models |
| Masimo Monitors | Radical-7, Radical (20-pin); Rad-97, Rad-97 NIBP, Rad-97 with NomoLine Capnography; Rad-87; Rad-8; Rad-5, Rad-5v |
| Masimo Handheld | Rad-57, Rad-57c, Rad-57cm, Rad-57m; Pronto, Pronto-7, Pronto with Next Generation SpHb |
| Physio-Control | Lifepak 15 |
| Zoll | X Series |
| Comen | K12 Pro |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2057 (Red LNC-14) (OEM is 14 ft) |
| GE Healthcare | 2059007-001 |
| Physio-Control | 11996-000325 |
| Draeger | MP03196 |
IPR Medical buys, sells, repairs, and stocks parts for Masimo rainbow SET oximeters, monitors, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Masimo Red LNC-14 Compatible SpO2 Patient Cable?
The Masimo Red LNC-14 (2057) compatible SpO2 patient cable is a reusable, aftermarket long-reach cable that connects standard Masimo LNCS pulse oximetry sensors to Masimo rainbow SET devices with the red 20-pin patient cable connector. It lets rainbow-platform monitors, oximeters, and defibrillators use LNCS sensors for routine SpO2 and pulse rate monitoring. It is a compatible replacement, not an original Masimo part, and it is built to OEM fit, form, and function.
Compatible Monitor Models
This compatible cable is confirmed for use with Masimo Radical-7 and Radical (20-pin) monitors, Rad-5, Rad-5v, Rad-8, Rad-87, and Rad-97 devices including Rad-97 NIBP and Rad-97 with NomoLine capnography, Rad-57, Rad-57c, Rad-57cm, and Rad-57m oximeters, and Pronto and Pronto-7 devices, including Pronto with Next Generation SpHb. It also fits the Physio-Control Lifepak 15, the Zoll X Series, and the Comen K12 Pro. The device must have a red Masimo rainbow SET patient cable connector; devices with the gray Masimo SET connector require a standard LNCS cable instead.
Design and Construction
The 11.8 ft (3.6 m) cable provides the longest reach in the Red LNC family, suited to ICU, OR, and NICU layouts where the monitor is boom- or wall-mounted well away from the patient. The monitor end uses the red 20-pin rainbow connector, and the sensor end accepts Masimo LNCS sensors in adult, pediatric, infant, and neonatal sizes, in both reusable and single-patient-use styles. Rainbow parameters such as SpHb and SpCO require rainbow sensors and cables; with LNCS sensors, this cable supports standard SpO2 and pulse rate monitoring. The cable is reusable after cleaning according to facility protocol and ships one per bag.
When to Replace Your Masimo Red LNC-14 Cable
Replace the cable when the device shows “SpO2 sensor off,” “no cable,” “replace cable,” or cable/sensor fault messages with a known-good LNCS sensor, when saturation or pleth readings drop out as the cable is moved, or when you find a cracked jacket, a loose sensor latch, or bent or corroded pins at the red connector. Long cables are more likely to be pinched in bed rails, rolled over by equipment, or stepped on, so inspect the full length of the jacket and both strain reliefs during routine checks.
Cross Reference and Interchange Part Numbers
This compatible Masimo Red LNC-14 patient cable, IPR Medical SKU SA-009RB-36LS, cross-references to Masimo 2057 (Red LNC-14), GE Healthcare 2059007-001, Physio-Control 11996-000325, and Draeger MP03196. The OEM Red LNC-14 is a 14 ft cable, so confirm the 11.8 ft (3.6 m) length suits your setup. IPR Medical also stocks the compatible Masimo Red LNC-10 (2056) at 9.8 ft, SKU SA-009RB-30LS, and Red LNC-4 (2055) at 3.9 ft, SKU SA-009RB-12LS.
Why Source SpO2 Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible Masimo red and gray connector cables, Nellcor, and TruSignal SpO2 accessories in multiple lengths for monitors, oximeters, and defibrillators, so biomedical teams can standardize sourcing at lower cost than OEM. Our team can help identify each device’s SpO2 technology and connector and support your equipment with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for Masimo rainbow SET oximeters, monitors, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.