Masimo Red MNC (2641) Compatible SpO2 Adapter Cable, 20-Pin to Nellcor Oxismart Sensors, 3.9 ft (1.2 m)
The Masimo Red MNC (2641) compatible SpO2 adapter cable (SKU SA-009RB-12) is a reusable, aftermarket replacement (not OEM) that lets Nellcor Oxismart-style sensors run on Masimo SET-equipped monitors, built to match the original’s fit, form, and function.
| SpO2 Technology | Nellcor Oxismart |
| Monitor Connector | 20-Pin Masimo Red |
| Sensor Connector | Nellcor-Style 9-Pin |
| Cable Length | 3.9 ft (1.2 m) |
| Lifecycle | Reusable |
| Replaces | Masimo 2641, Physio-Control 11996-000365, Zoll 8000-000460 |
Works with: Physio-Control Lifepak 15, Masimo-equipped Zoll X Series, Masimo Radical-7, Rad-5, Rad-8, Rad-57, Rad-87, Rad-97, and Pronto series monitors, and Comen K12 Pro. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SA-009RB-12 |
| Replaces OEM Part | Masimo 2641 (Red MNC) |
| Category | SpO2 Adapter Cable |
| Cable Length | 3.9 ft (1.2 m) |
| Monitor Connector | 20-Pin Masimo Red |
| Sensor Connector | Nellcor-Style 9-Pin |
| SpO2 Technology | Nellcor Oxismart |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Physio-Control (Stryker) | Lifepak 15 |
| Zoll | X Series |
| Masimo | Pronto, Pronto-7, Pronto with Next Generation SpHb, Rad-5, Rad-5v, Rad-8, Rad-57, Rad-57c, Rad-57cm, Rad-57m, Rad-87, Rad-97, Rad-97 NIBP, Rad-97 with NomoLine Capnography, Radical (20-Pin), Radical-7 |
| Comen | K12 Pro |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2641 (Red MNC) |
| Physio-Control (Stryker) | 11996-000365 |
| Zoll | 8000-000460 |
IPR Medical buys, sells, repairs, and stocks parts for the Masimo Red MNC SpO2 Adapter Cable. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Masimo, or any other manufacturer or supplier named on this page. Nellcor, Masimo, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Compatible Masimo Red MNC SpO2 Adapter Cable?
The Masimo Red MNC compatible SpO2 adapter cable (IPR SKU SA-009RB-12) is an aftermarket replacement for Masimo 2641, a cable that allows Nellcor Oxismart-style SpO2 sensors to be used on monitors and defibrillators equipped with a 20-pin Masimo Red input. It is a compatible replacement, not an OEM Masimo product, built to match the fit, form, and function of the original. Facilities that stock Nellcor sensors can use this cable to run those sensors on Masimo SET-equipped devices, which simplifies sensor inventory across mixed fleets. At 3.9 ft (1.2 m), it is sized for transport, EMS, and point-of-care configurations where a shorter cable keeps the sensor line manageable.
Compatible Monitor Models
This compatible adapter cable works with the Physio-Control Lifepak 15 monitor/defibrillator and Masimo-equipped Zoll X Series units, both common in emergency and transport settings. It is also compatible with Masimo pulse oximeters and Pulse CO-Oximeters including the Radical-7, Radical (20-pin), Rad-5, Rad-5v, Rad-8, Rad-57, Rad-57c, Rad-57cm, Rad-57m, Rad-87, Rad-97, Rad-97 NIBP, Rad-97 with NomoLine Capnography, Pronto, Pronto-7, and Pronto with Next Generation SpHb, as well as the Comen K12 Pro. Confirm that your device is configured for Masimo SET oximetry with a 20-pin Red input before ordering.
Design and Construction
The cable terminates in a 20-pin Masimo Red monitor connector on one end and a Nellcor-style 9-pin sensor connector on the other, so Nellcor Oxismart-compatible sensors plug in directly at the patient end. The 3.9 ft (1.2 m) length keeps excess cable to a minimum on stretchers, crash carts, and portable monitors. The cable is reusable and supplied one per bag.
When to Replace Your Red MNC SpO2 Adapter Cable
Adapter cables used in emergency and transport environments see heavy handling, and the connector ends are typically the first point of failure. Replace the cable when you see intermittent “sensor off” or “no sensor” alarms that clear when the cable is moved, signal dropouts that persist after a new sensor is installed, cracked or loose connector housings, bent or recessed pins, or cuts and kinks in the jacket. If a known-good Nellcor sensor fails to read on a monitor that passes self-test, the adapter cable is the fastest item to rule out. Keeping a spare on each truck or cart minimizes downtime on critical monitoring.
Cross Reference and Interchange Part Numbers
This compatible cable cross-references to Masimo 2641 (Red MNC), Physio-Control 11996-000365, and Zoll 8000-000460. All three numbers identify the 4 ft OEM Red MNC adapter cable distributed for Masimo, Lifepak 15, and Zoll applications. This listing is the 3.9 ft (1.2 m) compatible version.
Why Source Masimo-Compatible SpO2 Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment. Compatible SpO2 adapter cables give EMS agencies, biomedical departments, and materials managers a cost-effective way to keep Masimo-equipped monitors and defibrillators in service without paying OEM pricing. Our team can confirm fit against your monitor model and sensor line before you order, and we also offer in-house repair services, replacement parts, and refurbished equipment, so you can source accessories and service from a single partner.
IPR Medical buys, sells, repairs, and stocks parts for the Masimo Red MNC SpO2 Adapter Cable. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Masimo, or any other manufacturer or supplier named on this page. Nellcor, Masimo, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.



















