The Philips Avalon CL Wireless Transducer Base Station (866074) is the hub of the Philips Avalon CL cableless fetal monitoring system — the docking station, charger, and wireless gateway that transforms a wired Avalon fetal monitor into a fully cableless L&D solution. A single 866074 base station docks up to three cableless fetal transducers (866075 Toco+ MP, 866076 Ultrasound, and 866077 ECG/IUP) plus one maternal parameters slot for an IntelliVue CL Pod or range extension module, with a total assignment capacity of four CL transducers and two CL Pods. It connects to any Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor via the fetal sensor socket — or to the rear telemetry connectors on the FM40 and FM50 — and delivers a line-of-sight operating range of up to 100 m (300 ft).

Docked transducers and pods are assigned and recharged automatically, so labor teams can grab a patient-ready device and apply it with no setup. The 866074 base station is required for all Avalon CL transducers and pods. IPR Medical sells, buys, repairs, and stocks parts for the Philips Avalon CL system — including base stations, transducers, antennas, power supplies, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: philips-avalon-cl-base-station-866074 Category: Brand:
Send In Philips Avalon CL Wireless Transducer Base Station (866074) for Repair

Philips Avalon CL Wireless Transducer Base Station (866074) Specifications

The Philips 866074 is the base station for the Avalon CL Fetal Transducer System. It houses three docking slots for cableless fetal transducers plus one slot for maternal parameters or a range extension module, manages wireless telemetry to the fetal monitor, and recharges docked transducers and pods.


OEM Part Number 866074
Device Type Base station for Avalon cableless transducers
Slot Configuration 3 slots for cableless fetal transducers + 1 slot for maternal parameters (IntelliVue CL Pod) or range extension module
Total Assignment Capacity Up to 4 CL transducers and 2 IntelliVue CL Pods per base station
Compatible Cableless Transducers 866075 Toco+ MP, 866076 Ultrasound, and 866077 ECG/IUP
Compatible Fetal Monitors Philips Avalon FM20, FM30, FM40, and FM50
Monitor Connection Any fetal sensor socket on FM20/30/40/50, or rear telemetry connectors on FM40/50
Dual Base Station Support FM40/50 supports two 866074 base stations (left telemetry socket used for primary radio communication)
Required Monitor Software Avalon fetal monitor software release J.3 or higher
CL Pods Software Option CL2 software option required to operate IntelliVue CL SpO2 and CL NBP Pods (not available for FM20/30 #E25 battery option)
Operating Range Up to 100 m (300 ft) line of sight; effective range varies with building geography and underwater use
Wireless Technology Philips IntelliVue Instrument Telemetry — Short-Range Radio, IEEE 802.15.4
Antenna Standard Philips antenna compatible (sold separately); remote antenna system available for facilities with non-standard mounting or coverage needs
Transducer Charging Automatic recharging of docked CL transducers and CL Pods whenever base station is powered and connected to fetal monitor
Assignment Behavior Docked transducers and pods are assigned and paired to the connected monitor automatically — no manual configuration required
Built-In Alarms Loss of radio connection, low or depleted transducer battery, and cableless transducer malfunction
Power Supply AC mains via included hospital-grade power cord; 3-wire grounded receptacle required
Front Panel Controls On/Stand-by switch on front panel; transducer status LEDs at each slot
Rear Interfaces AC mains socket, equipotential terminal, service socket (3.5 mm stereo jack), fetal monitor interface socket, and antenna input
Dimensions (Approx.) 13.7 × 7.2 × 2.9 in (348 × 183 × 74 mm)
Weight (Approx.) 2.2 lbs (0.98 kg)
Mounting Options Standard cart drawer, desk or flat surface, on-monitor bracket mount, or GCX mounting adapter (mounting hardware sold separately)
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Operating Humidity Less than 95% relative humidity at 113°F (45°C)
Storage Humidity Less than 90% relative humidity at 140°F (60°C)
Operating Altitude -1,640 to 9,840 ft (-500 to 3,000 m)
Storage/Transportation Altitude -1,640 to 43,000 ft (-500 to 13,100 m)
Safety Classification Protection Class I — requires 3-wire grounded power connection
Intended Use Environment Healthcare facility only; not intended for domestic use
Purchase Scope Base station and hospital-grade AC power cord only — no cableless transducers, IntelliVue CL Pods, telemetry interface cables, antennas, or mounting accessories included. Cableless transducers (866075, 866076, 866077), CL Pods, interface cables, and antennas are sold separately. Contact IPR Medical to build a complete Avalon CL kit.

IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Transducer Base Station (866074). Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.

The hub of the Avalon CL cableless system

Every Avalon CL cableless transducer and every IntelliVue CL Pod needs a base station, and the 866074 is it. The base station is the wireless gateway between the cableless devices and the Philips Avalon fetal monitor — it receives the radio signals from docked or untethered transducers, handles pairing and identification, charges the transducer batteries, and passes the measurement data to the monitor for display, recording, and alarm processing. Without the 866074, the 866075, 866076, and 866077 transducers cannot be used. It is the single required piece of equipment that enables every cableless workflow on an Avalon FM20, FM30, FM40, or FM50.


Three fetal slots plus one maternal slot

The 866074 is designed with three docking slots for cableless fetal transducers — enough to cover the full Avalon CL lineup simultaneously (Toco+ MP, Ultrasound, and ECG/IUP) — plus a fourth slot dedicated to maternal parameters or a range extension module. That fourth slot is where the IntelliVue CL SpO2 and CL NBP Pods charge and pair, enabling fully cableless maternal vital signs alongside fetal monitoring. A single base station can have up to four CL transducers and two CL Pods assigned to it, so a facility can monitor twins or triplets with multiple ultrasound transducers while simultaneously tracking maternal pulse oximetry and blood pressure wirelessly.


100 m range and automatic assignment

The 866074 communicates with docked and in-use transducers over Philips IntelliVue Instrument Telemetry — a Short-Range Radio (IEEE 802.15.4) protocol that delivers a line-of-sight operating range of up to 100 m (300 ft). That range is what makes labor ambulation, shower monitoring, and birthing tub hydrotherapy practical on Avalon CL. Assignment is automatic: when a transducer or pod is docked at the base station, it is paired and charged without any manual configuration. Clinicians simply pick up a patient-ready device and apply it — no menu navigation, no numeric pairing codes, no dropped traces when a patient leaves the room for imaging or a walk.


Connects to any Avalon FM20/30/40/50

The 866074 plugs into any fetal sensor socket on the Avalon FM20, FM30, FM40, or FM50 — or into the dedicated rear telemetry connectors on the FM40 and FM50. For larger L&D floors, the FM40 and FM50 can host two base stations simultaneously (one on each telemetry socket), expanding transducer and pod capacity. When two base stations are connected, the base station on the left telemetry socket is used for primary radio communication and should be mounted for optimal RF line of sight; the second base station can be placed in a drawer or enclosed space since it handles charging and assignment only. Avalon fetal monitor software release J.3 or higher is required to operate the Avalon CL system, and the CL2 software option (license-dependent) is required to enable the IntelliVue CL Pods.


Built-in alarms and transducer management

The base station monitors every assigned device continuously. Loss-of-radio alarms alert clinicians if a transducer moves out of range or loses signal due to interference, low-battery and out-of-battery alarms flag a transducer before the trace is interrupted, and malfunction alarms indicate a hardware fault. Each slot on the front panel has status LEDs — green or yellow indicators that signal when a docked device is ready for use. An on/stand-by switch on the front panel controls the base station operating mode; wired transducers can continue to be used on the fetal monitor with the base station in stand-by, no cable disconnection required.


Flexible mounting for any L&D layout

At approximately 13.7 × 7.2 × 2.9 inches and 2.2 lbs, the 866074 fits in a standard cart drawer (Philips Carts CL, CX, and CM are all designed to accommodate it), on top of a cart or desk using the supplied mounting brackets, on top of the FM40/50 fetal monitor directly, or on a GCX adapter for articulated wall or pole mounting. A remote antenna system is also available for installations where the base station cannot be mounted with good RF line of sight — typically required when the 866074 is placed inside a metal drawer or cabinet. IPR Medical can advise on antenna extension configurations for challenging installations.


Common failure modes and what we fix

In field use, the most common reasons for 866074 failure are liquid damage to the charging contacts, physical damage to the housing from drops or cart impacts, and power supply issues. IPR Medical services all of these — contact cleaning, housing and bracket replacement, power supply and switchboard PCA repair or replacement, antenna socket service, and full functional testing using Philips-specified test procedures. We also handle firmware and software updates to bring older base stations up to the current Avalon CL release, which is required when customers upgrade their FM20/30/40/50 monitors to newer software revisions.


IPR Medical — sales, repairs, parts, and service

IPR Medical sells refurbished and patient-ready Philips Avalon CL base stations, and we buy surplus or decommissioned 866074 units from facilities upgrading their fetal monitoring fleet. Our service team performs power supply repair, antenna socket service, charging interface service, housing replacement, and firmware updates on the 866074 using Philips-specified procedures and test equipment. We also stock replacement antennas, AC power cables, telemetry interface cables for the FM20/30/40/50, and the complete Avalon CL transducer line — so a single call covers the base station, the transducers, the accessories, and the service that keeps the system running.

IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Transducer Base Station (866074). Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.

Product Condition

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips Avalon CL Wireless Transducer Base Station (866074). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


Avalon CL Cableless Transducers

866075 Philips Avalon CL Toco+ MP Cableless Transducer — Toco and Smart Pulse with connector for MECG, DECG, or IUP
866076 Philips Avalon CL Ultrasound Cableless Transducer — external fetal heart rate
866077 Philips Avalon CL ECG/IUP Cableless Transducer — MECG, DECG, and IUP measurement

Compatible Fetal Monitors

Avalon FM20 Mid-tier Philips fetal monitor; connects to 866074 via fetal sensor socket (software J.3+ required)
Avalon FM30 Mid-tier Philips fetal monitor with integrated maternal SpO2; connects to 866074 via fetal sensor socket (software J.3+ required)
Avalon FM40 Advanced Philips fetal monitor; supports up to two 866074 base stations via fetal sensor sockets or rear telemetry connectors
Avalon FM50 Top-tier Philips fetal monitor; supports up to two 866074 base stations via fetal sensor sockets or rear telemetry connectors

IntelliVue CL Pods (Maternal Vital Signs)

CL SpO2 Pod Wireless maternal pulse oximetry pod; requires CL2 software option on the fetal monitor
CL NBP Pod Wireless maternal non-invasive blood pressure pod; requires CL2 software option on the fetal monitor

Cables and Connectivity

AC Power Cable Hospital-grade AC mains cable for the 866074 base station; 3-wire grounded plug
Fetal Monitor Interface Cable Telemetry interface cable connecting the 866074 to the fetal sensor socket or rear telemetry connector on Avalon FM20/30/40/50
Service Cable 3.5 mm stereo jack service cable for connecting the Philips IntelliVue Support Tool (authorized service personnel)

Antenna and RF Accessories

Standard Antenna Replacement standard antenna with right-angle BNC connector for the 866074 antenna input
Antenna Extension Kit (M1361A Option 1AA) Extension kit used when the base station is mounted in a drawer or cart where the standard antenna cannot achieve adequate RF line of sight
Remote Antenna System Facility-wide remote antenna installation for extended coverage beyond standard line-of-sight range (Philips-designed and installed)

Mounting Solutions

Mounting Brackets Standard Philips mounting brackets for desk, cart-top, or on-monitor placement of the 866074
GCX Mounting Adapter (PH-0042-80) GCX-compatible adapter for mounting the 866074 on GCX wall channels, poles, or articulated arms
Philips Carts (CL/CX/CM) Philips carts designed to hold the 866074 with docked transducers in the drawer

Service and Replacement Components

Top Cover Assembly Complete top cover with HIF board, keypad inlay, and battery charge contacts (serviced as a complete assembly per Philips)
Chassis / Power Supply Assembly Metal chassis with integrated power supply; serviced as a complete assembly per Philips procedures
Receiver Board (MIF) Monitor interface and receiver board for wireless communication and fetal monitor interface
Charging Contacts Slot-level charging contact service — most common repair due to liquid damage or oxidation
Firmware / Software Updates IPR Medical performs Avalon CL base station firmware updates to match fetal monitor software release (J.3 and later)

IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Transducer Base Station (866074). Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.