Jorgensen Labs Jorvet Vet-Pro VIP 2000
The Jorvet Vet-Pro VIP 2000 is a compact veterinary infusion pump manufactured by Caesarea Medical Electronics and distributed through Jorgensen Labs. At under 1 lb with battery and barely larger than a soda can, it is one of the smallest and lightest veterinary infusion pumps available — purpose-built for clinic, mobile, and home care environments where portability and ease of use are priorities.
Despite its compact size, the Vet-Pro 2000 delivers a comprehensive clinical feature set: five infusion programs including Continuous, 25-Step Protocol, TPN with automatic taper up/down, Intermittent, and PCA with up to five lockable drug protocols. Flow rates range from 0.1 to 1,200 ml/h at ±5% accuracy, with an ultrasonic adjustable air-in-line sensor, three-level adjustable occlusion pressure, Anti-Bolus System (ABS), and a 15-hour battery life at 125 ml/h. The pump latches into a pole-mounted charger and charges automatically whenever connected.
IPR Medical buys, sells, repairs, and stocks parts for the Vet-Pro VIP 2000, keeping these reliable pumps in service for veterinary practices across the country.
Also available from IPR Medical:
- PETite™ – Touchscreen veterinary IV pump
- PETite Heat™ – PETite with integrated inline fluid warmer
- SnipPet™ – Non-touchscreen veterinary IV pump
- PETfusion™ – Touchscreen veterinary syringe pump
- InfuPet™ – Non-touchscreen veterinary syringe pump
- View all IPR Medical veterinary pumps →
Jorvet Vet-Pro VIP 2000 Veterinary Infusion Pump
Ultra-compact veterinary volumetric infusion pump weighing under 1 lb. Five infusion programs including Continuous, 25-Step Protocol, TPN with auto-taper, Intermittent, and PCA. Flow rates 0.1–1,200 ml/h at ±5% accuracy. Ultrasonic adjustable air sensor, Anti-Bolus System, 15-hour battery life. IPR Medical buys, sells, repairs, and stocks parts for the Vet-Pro VIP 2000.
| Manufacturer | Jorgensen Labs / Jorvet / Caesarea Medical Electronics Ltd (CME) |
| Pumping Mechanism | Piston mechanism; 1.8 mcL linear infusion |
| Infusion Programs | Continuous, 25-Step Protocol, TPN (auto taper up/down), Intermittent, PCA |
| Flow Rate Range | 0.1 – 1,200 ml/h (Continuous, 25-Step, TPN, Intermittent); 0–100 ml/h (PCA); increments of 0.1 or 1 ml/h |
| Accuracy | ± 5% |
| VTBI | 0.1–9,999 ml (Continuous, TPN, Intermittent); up to 1,000 ml (PCA); up to 9,999 ml per step / 10 liters accumulated (25-Step) |
| KVO Rate | 0.1 – 5 ml/h (adjustable); KVO volume limited to 5 ml |
| PCA Program | Up to 5 lockable protocols with drug names; continuous basal rate plus programmable boluses; lockout time between boluses; 4-hour volume limit; MD bolus; 24-hour history with graphical display |
| 25-Step Protocol | Up to 25 steps, each with independent rate and volume; accumulated volume up to 10 liters; rate taper with programmable up and down times |
| TPN Program | Trapezoid infusion pattern with programmable taper-up time, flat rate, and taper-down time; pump calculates and displays maximum rate for verification |
| Anti-Bolus System | ABS — automatically reverses pump mechanism upon downstream occlusion alarm to return line pressure to neutral within 15 seconds; prevents inadvertent bolus on occlusion release; max single fault volume ≤0.1 ml |
| Air-in-Line Sensor | Ultrasonic; adjustable single-bubble threshold; plus cumulative air accumulation detection over a 0.5 ml moving window |
| Occlusion Pressure | 3 selectable levels: Low — 5 psi, Normal — 7.5 psi, High — 10 psi (default); adjustable per session |
| Program Locking | 3 levels: Key lock (Level 1), Program lock / parameter lockout (Level 2, code 902), Maximum rate lock (Level 3, code 901) |
| Program Delay | Up to 20 hours (available in Continuous, TPN, and 25-Step programs); KVO runs during delay period |
| History Log | Up to 1,000 events; BodyComm software (PC) for history review and pump settings management |
| Display | Graphic LCD; displays rate, VTBI, volume infused, time remaining, battery level, program status; numeric keypad with arrow keys and dedicated function keys |
| Classification | Type CF; ABS fire-retardant housing |
| Power — AC | 110–240 VAC, 50/60 Hz, 20W (via pole-mounted charger base) |
| Battery | Li-Ion 7.2V, 1,800 mAh rechargeable; ≥15 hours runtime at 125 ml/h; automatic charging when latched in charger; charge time approx. 4 hours; replace every 2 years |
| Mounting | Latches into pole-mounted charger base; can also be used as a fully portable standalone unit |
| Dimensions | 4.4″ L × 3.5″ W × 1.3″ H |
| Weight | Approx. 0.62 lbs without battery; approx. 0.86 lbs with battery |
| Alarms | Air in Line, Door Open, Down Occlusion, End Program, Low Battery, End Battery, Pump Unattended, Internal Malfunction, Locking State, Missing Key |
| Operating Environment | Temperature: 59–113°F; Humidity: 20–90% |
| Storage / Transport | Temperature: -13–122°F; Humidity: 5–100% |
| Standards | EN 60601-1, IEC 60601-2-24, IEC 60601-1-4, UL 2601-1, CAN/CSA C22.2 No. 601.1; ISO 9001:2000; ISO 13485:2003; CE marked |
IPR Medical buys, sells, repairs, and stocks parts for the Jorvet Vet-Pro VIP 2000. Contact us for unit availability, parts inventory, repair turnaround, and pricing at 855-477-8866 or cs@IPRmed.com.
Trademark Notice: Jorgensen Labs, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Jorgensen Labs.
The smallest pump in veterinary practice — with a full clinical feature set
The Vet-Pro VIP 2000 is one of the most compact and lightweight veterinary infusion pumps ever made. At under 1 lb with battery and measuring just 4.4″ × 3.5″ × 1.3″, it is barely larger than a soda can — yet it delivers five complete infusion programs, a 15-hour battery life, ultrasonic air detection, and a full locking and PCA system that many larger pumps don’t match. It latches into a pole-mounted charger base and charges automatically whenever it is docked. Detach it and carry it — the pump runs entirely on battery with no change to operation.
Five infusion programs for any clinical scenario
The Vet-Pro 2000 offers five programs selectable from the keypad. Continuous mode covers standard rate-over-volume or volume-over-time infusions from 0.1 to 1,200 ml/h. The 25-Step Protocol allows up to 25 individually configured rate-and-volume steps in sequence — up to 10 liters accumulated — with a programmable rate taper. TPN mode delivers a full trapezoid infusion pattern with configurable taper-up time, flat rate period, and taper-down time; the pump calculates and displays the maximum rate for verification before starting. Intermittent mode runs a dose-at-interval program with KVO between doses — useful for IV antibiotic protocols and similar scheduled therapies. PCA mode combines a continuous basal rate with up to five lockable, named drug protocols, lockout time between boluses, a 4-hour volume limit, and a 24-hour graphical bolus history.
Anti-Bolus System and ultrasonic air detection
The built-in Anti-Bolus System (ABS) automatically reverses the pump mechanism upon a downstream occlusion alarm, returning line pressure to neutral within 15 seconds. This prevents the inadvertent fluid bolus that can occur when a downstream clamp is released after an occlusion — a meaningful safety feature for any patient but particularly important for small and pediatric-equivalent veterinary patients. The maximum volume deliverable under a single fault condition is 0.1 ml. The ultrasonic air sensor provides both single-bubble detection at an adjustable threshold and a cumulative air accumulation function that monitors total air volume over a 0.5 ml moving window — catching the small repeated bubbles that single-event sensors miss.
Three-level locking for secure clinical and home care use
The Vet-Pro 2000 supports three independent locking levels. Level 1 key-locks the keypad to prevent accidental changes during infusion. Level 2 locks the program parameters entirely — useful for home care patients who repeat the same protocol daily without staff present. Level 3 sets a maximum rate ceiling, allowing the pump to be operated within a safe upper boundary regardless of what rate a user attempts to enter. All locking levels are code-protected and persist in memory until changed.
IPR Medical — sales, repairs, and parts for the Vet-Pro VIP 2000
IPR Medical buys, sells, repairs, and stocks replacement parts for the Jorvet Vet-Pro VIP 2000. Whether you need a patient-ready refurbished unit, a specific replacement component, or repair service on a pump already in your fleet, our team is ready to help. The Vet-Pro 2000 remains a popular and reliable pump in veterinary practice, and IPR Medical keeps them in service.
IPR Medical buys, sells, repairs, and stocks parts for the Jorvet Vet-Pro VIP 2000. Contact us for unit availability, parts inventory, repair turnaround, and pricing at 855-477-8866 or cs@IPRmed.com.
Trademark Notice: Jorgensen Labs, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Jorgensen Labs.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 8 in |
Reviews