Philips Avalon FM50 Fetal Monitor | Intrapartum, DECG & IUP

$2,495.00

The Philips Avalon FM50 is an intrapartum fetal/maternal monitor for labor and delivery rooms and antepartum testing areas, combining external ultrasound and Toco monitoring with internal direct fetal ECG (DECG) and intrauterine pressure (IUP). It monitors singletons, twins, and optionally triplets on one 6.5-inch color touchscreen, prints to a built-in thermal trace recorder, and connects to Philips OB TraceVue and IntelliSpace Perinatal over LAN.

Display 6.5-inch color touchscreen; VGA output for an external display
Fetal Parameters Ultrasound FHR (twins standard, triplets optional), fetal movement profile, DECG, Toco, IUP
Maternal Parameters MECG heart rate and wave, Smart Pulse from Toco; NIBP, SpO₂, and tympanic temperature by option
Signal Verification Cross-channel verification (automated coincidence detection)
Recorder Built-in thermal array recorder, Z-fold paper, 1, 2, or 3 cm/min
Connectivity LAN/RS232 to OB TraceVue or IntelliSpace Perinatal; rear connection for Avalon CL or Avalon CTS cableless systems

IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon FM50 Fetal Monitor. Contact us at 855-477-8866 or cs@iprmed.com.

Also available from IPR Medical:
Philips Avalon CL Base Station — cableless transducer base station for Avalon fetal monitors  |
Philips Avalon CL Toco+ MP Transducer — cableless Toco with Smart Pulse  |
Philips Avalon CL Ultrasound Transducer — cableless fetal heart rate  |
Philips Avalon CL ECG/IUP Transducer — cableless DECG, MECG, and IUP

SKU: philips-avalon-fm50-fetal-monitor Category: Brand:
Send In Philips Avalon FM50 Fetal Monitor | Intrapartum, DECG & IUP for Repair

Philips Avalon FM50 — Specifications


Manufacturer Philips Healthcare
Model Avalon FM50
Model Versions (OEM-identified) M2705A
Device Classification Fetal/maternal monitor for intrapartum and high-risk antepartum monitoring
Intended Use Antepartum testing areas, labor and delivery rooms, and postpartum recovery in the hospital; not intended for ICU or OR use
Patient Categories Pregnant women; singleton, twin, and triplet fetuses
Display 6.5-inch color touchscreen
User Interface Touchscreen with configurable SmartKeys; optional PS/2 or USB keyboard, mouse, and bar code reader; optional external touch display
External Fetal Parameters Ultrasound FHR (twins standard, triplets optional), fetal movement profile (FMP), external Toco
Internal Fetal Parameters Direct fetal ECG (DECG) heart rate and wave, intrauterine pressure (IUP)
Maternal Parameters MECG heart rate and wave, maternal pulse from Toco (Smart Pulse); NIBP, SpO₂, and tympanic temperature are option-dependent
Ultrasound FHR Pulsed Doppler, 1 MHz; 50–240 bpm; thermal and mechanical index always below 1.0
DECG / MECG Heart Rate 30–240 bpm; ±1 bpm or 1%, whichever is greater
Maternal Pulse from Toco 40–240 bpm; ±2% or 1 bpm, whichever is greater
Toco Strain gauge sensor; signal range 0–127 units; auto offset to 20 units
IUP Passive resistive strain gauge; measurement range -100 to +300 mmHg
NIBP (optional) Systolic 30–270 mmHg, diastolic 10–245 mmHg, mean 20–255 mmHg; pulse rate 40–300 bpm
SpO₂ (optional) 0–100%; pulse rate 30–300 bpm; Philips, Nellcor OxiMax, and Masimo sensor families supported
Cross-Channel Verification Standard; compares fetal and maternal heart rates and issues a Coincidence INOP
FHR Alarm Limits Low 60–200 bpm (default 110); high 70–210 bpm (default 170)
Recorder Built-in thermal array recorder; standard Z-fold paper; 1, 2, or 3 cm/min; 5.0-inch print width; 200 dpi
Trace Backup Memory Minimum 3.5 hours with software J.3 or later; minimum 7 hours with mainboard hardware revision A 00.18
Software Versions J.3x.xx and L.3x.xx releases documented. See the Description Tab for release detail.
Power 100–240 VAC ±10%, 50–60 Hz, 1.3–0.7 A; AC mains operation (no internal battery)
Electrical Safety Class I equipment; Type CF applied parts; IPX1 with recorder drawer shut; not defibrillator-protected
Dimensions (W x H x D) 16.6 x 6.9 x 14.4 inches (without options)
Weight Less than 19.5 lbs
Operating Environment 32°F to 113°F; below 95% relative humidity at 104°F; -1,640 to 9,840 ft altitude
Storage Temperature -4°F to 140°F
Connectivity Optional LAN/RS232 system interface (100Base-TX, RJ45); VGA video output; rear telemetry interface; optional dual PS/2, dual MIB/RS232, quad USB, or flexible nurse call interface
Cableless Monitoring Up to two Avalon CL base stations or one Avalon CTS system via the rear telemetry interface
EMR / Enterprise Integration OB TraceVue E.00.00 or later and IntelliSpace Perinatal H.0 or later over LAN; RS232 read-only secondary output. See the Description Tab.
Maintenance Interval Safety checks, performance assurance, and NIBP calibration at least once every two years
Regulatory FDA 510(k) K092028 (Feb 17, 2010), K111083 (Aug 17, 2011), K140535 (Nov 25, 2014); product code HGM; 21 CFR 884.2740; Class II; Rx only
FDA Device Corrections Two Class II corrections named the FM50 (2009 ultrasound FHR labeling addendum; 2014 software J.30.58 NIBP sequence issue), both terminated. A 2024 Class II correction covers the 867246 ultrasound transducer. See the Description Tab.

IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon FM50 Fetal Monitor. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Masimo, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips, Masimo, or Nellcor.

Overview

The Philips Avalon FM50 (M2705A) is the intrapartum model of the Avalon FM40/FM50 fetal/maternal monitor pair, built for labor and delivery rooms, antepartum testing areas, and postpartum recovery in the hospital. It shares every feature of the Avalon FM40 and adds the internal measurements needed during active labor: direct fetal ECG (DECG) from a fetal scalp electrode and intrauterine pressure (IUP) from a catheter, both connected through a Toco+ transducer or an ECG/IUP module. Philips labels the FM50 with the IP (intrapartum) designation for this reason. Externally, the monitor tracks fetal heart rate by ultrasound for singletons and twins as standard, with triplet monitoring available as an option, along with uterine activity by Toco and gross fetal body movements through the Fetal Movement Profile. The Avalon family, which also includes the FM20, FM30, and FM40, shares transducers, accessories, and software, so facilities running mixed Avalon fleets can standardize on one set of transducers, one paper stock, and one software release across bedside and triage locations. Philips states that the FM50 is not intended for intensive care units or operating rooms.


Display and User Interface

The FM50 is operated almost entirely from its 6.5-inch color touchscreen, which shows measurement numerics, maternal and fetal ECG waves, alarm fields, status indicators, and menus. The only hardware control outside the screen is the On/Standby button. Configurable SmartKeys give one-touch access to common tasks such as starting the recorder, entering notes, starting NIBP, calling an ambulating patient wearing cableless transducers, and quick-admitting a patient. Smart transducers are recognized automatically when plugged in, and the monitor rebuilds its screen layout around the active measurements, while a finder LED on each transducer helps staff identify which one is assigned to which channel. A rear VGA output drives an external display approved for medical use at a cable run of up to about 33 feet, and an optional MIB interface supports an external touch display so the monitor can be operated from across the room or a family-facing screen. Optional PS/2 and USB interfaces add a keyboard, mouse, or bar code reader for admission workflows. With IntelliSpace Perinatal revision K or later and the IntelliVue XDS solution, clinicians can also view and operate a LAN-connected FM50 remotely.


Clinical Measurements and Transducer Support

External fetal heart rate is measured by 1 MHz pulsed Doppler ultrasound across 50–240 bpm, with Philips specifying that thermal and mechanical index remain below 1.0. Twin FHR monitoring is standard, and the triplet option adds a third ultrasound channel with configurable trace separation offsets on the recorder so overlapping traces remain readable. Internal fetal heart rate is derived from a single-lead DECG across 30–240 bpm, and the FM50 displays the DECG waveform for signal-quality assessment. Uterine activity is measured externally by a strain-gauge Toco transducer or internally by IUP over a measurement range of -100 to +300 mmHg. On the maternal side, heart rate comes from MECG electrodes, and a Toco MP or Toco+ MP transducer adds Smart Pulse, an optical maternal pulse measurement from 40–240 bpm. The operator manual lists maternal NIBP, SpO₂ (Philips, Nellcor OxiMax, and Masimo sensor families), and tympanic temperature as options, so the installed configuration should be confirmed on each unit. The FM50 accepts both previous-generation and new-generation wired Avalon transducers across four front fetal sensor sockets. Philips notes that the ECG display is for signal quality only and that the monitor is not a diagnostic ECG device.


Software Versions and Platform Evolution

Avalon fetal monitor software is released by lettered revision, and the same release covers the FM20, FM30, FM40, and FM50. Release J.3 (software J.3x.xx) introduced support for the Avalon CL cableless transducer system with twin and triplet capability, the IntelliVue CL SpO₂ and NBP Pods, cableless ECG/IUP, underwater monitoring with watertight CL transducers, and patient calling. J.3 also redesigned the user interface, added maternal tympanic temperature and manual temperature entry, configurable SpO₂ recording and transmission intervals, an audible Coincidence INOP, DHCP support, data export over LAN or MIB/RS232, a configurable NBP measurement sequence, alarm reminders, and optional USB and flexible nurse call interfaces. J.3 increased trace backup memory to at least 3.5 hours, or at least 7 hours on units with mainboard hardware revision A 00.18. Release L.3 (software L.3x.xx), the current release documented in the Philips operator manual, added the Avalon CL Wide Range Pod for WLAN-based ambulatory monitoring, support for the new-generation wired transducers, IntelliVue XDS remote display support, typed notes of up to 30 characters, and an alarm mode default of All. The new-generation wired Toco+ MP transducer requires L.3x.xx. Two L.3 features, the CL Fetal & Maternal Pod and Dawes/Redman NST interpretation, are not available in the U.S. Note that a software upgrade clears stored trace memory. IPR Medical can identify the software and hardware revision installed on a specific unit before sale or service.


Power, Recorder, and Physical Configuration

The FM50 is a mains-powered bedside monitor. It runs on 100–240 VAC ±10% at 50–60 Hz, draws 1.3–0.7 A, and is Class I equipment requiring an earthed outlet; Philips advises against extension cords and multiple portable socket-outlets. Unlike the FM20 and FM30, which offer a lithium-ion battery option for in-transport monitoring, the FM40 and FM50 have no internal battery. The unit measures 16.6 x 6.9 x 14.4 inches (W x H x D) without options and weighs less than 19.5 lbs, and it starts displaying parameter labels in under 30 seconds. The front panel carries the touchscreen, the recorder paper drawer and transparent paper guide with tear-off edge, the four fetal sensor sockets, and the optional NIBP and SpO₂ sockets. The built-in thermal array recorder prints on standard Z-fold paper at 1, 2, or 3 cm/min across a 5.0-inch print width at 200 dpi, uses optical sensing of black page marks, and fast-prints stored traces at up to about 0.8 inches per second. Philips calls for cleaning the thermal printhead at each paper pack change. Operating range is 32°F to 113°F at below 95% relative humidity at 104°F, and the enclosure is rated IPX1 with the recorder drawer shut.


Trace Recovery, NST Reporting, and Cross-Channel Verification

The FM50 keeps trace data and annotations in internal backup memory so traces are not lost when paper runs out or the drawer is open. When new paper is loaded, the monitor can automatically fast-print the missed interval from the stored data, and at least one hour of recovery data is available for printout. On a LAN connection, stored data uploads to OB TraceVue or IntelliSpace Perinatal automatically when the link is restored, provided the patient has an open episode. Buffered memory retains active settings, alarm review, and stored trace data for at least eight hours without power, and the alarm review log holds 300 items. Cross-channel verification is standard: the monitor compares all monitored maternal and fetal heart rates, flags any two channels picking up the same or similar signal with a Coincidence INOP and a configurable tone, and marks the affected numerics and trace with a question mark, helping staff avoid mistaking a doubled maternal heart rate for the fetal rate. Philips still instructs users to confirm fetal life and check maternal pulse periodically. An NST timer is standard, and optional NST trace interpretation based on the 2008 NICHD guideline prints a report on the fetal strip for up to three fetal heart rates.


Network and OB Information System Integration

The FM50 connects to Philips OB TraceVue and IntelliSpace Perinatal, the Philips obstetrical surveillance and information management systems, through the optional LAN/RS232 system interface in rear slot 01. LAN connection requires OB TraceVue revision E.00.00 or later or IntelliSpace Perinatal revision H.0 or later, and the network port is 100Base-TX on an RJ45 connector with basic isolation. The monitor supports both BOOTP and DHCP addressing. While connected over LAN, the monitor takes its date and time from the OB system, including daylight saving changes, and local date and time settings are locked. When a LAN connection to the OB system is active, the RS232 port can serve a second system, such as an EMR, on a read-only basis; that system can read output data but cannot change ADT data or monitor settings. Measurement data export is also available over LAN or the optional MIB/RS232 interface, although Philips notes that compatibility with third-party obstetrical systems has not been verified and must be validated before clinical use. For cableless monitoring, the rear telemetry interface accepts up to two Avalon CL base stations or one Avalon CTS system.


FDA Device Corrections and Safety Bulletins

Two FDA-classified corrections have named the Avalon FM50 directly, and both are now terminated. In November 2009, Philips issued an Urgent Medical Device Recall notice with an Instructions for Use addendum covering the Avalon FM20, FM30, FM40, and FM50, including all FM50 serial numbers (FM50 recall Z-0552-2010, Class II), after complaints of inaccurate ultrasound-derived fetal heart rate readings. Philips stated that the inaccuracies reflected known limitations of ultrasound FHR monitoring but occurred more frequently than with the previous Series 50 monitors; the correction was a labeling addendum explaining these phenomena and the differences from Series 50 displays. In October 2014, Philips issued an Urgent Medical Device Correction for FM20, FM30, and FM50 monitors running software revision J.30.58 (FM50 recall Z-0105-2015, Class II): with NBP in time-synchronized automatic or sequence mode, the automatic NBP series could stop, and the root cause was a software design change. Philips corrected it with a no-charge software upgrade. Separately, in May 2024 Philips issued an Urgent Medical Device Correction for the 867246 Avalon ultrasound transducer used with the FM50 (Z-2239-2024, Class II, listed as ongoing by FDA): transducers with transducer software L.01.04 can produce inaccurate fetal heart rates when monitoring multiples and must be used only for singletons.

Recommended actions: Confirm that each FM50 is running software newer than J.30.58, and if it is not, restart automatic NBP measurement whenever the repetition interval is changed until the software is upgraded. Keep the 2009 Instructions for Use addendum with the monitor labeling and train staff on ultrasound FHR limitations, including doubled maternal heart rate. Check the software revision of every 867246 ultrasound transducer, remove any unit at L.01.04 from twin or triplet monitoring, and use unaffected transducers or the Avalon CL ultrasound transducer for multiples.

Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.

FDA resources for further review:
FDA Medical Device Recalls Database  |
FDA Medical Device Safety


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical supports the Avalon FM50 across its full service life. We sell tested FM50 monitors configured to your requirements, including triplet capability, NIBP and SpO₂ options, and the LAN/RS232 system interface for OB TraceVue or IntelliSpace Perinatal. Our technicians repair FM50 monitors in-house, covering touchscreen displays, thermal recorders, fetal sensor sockets, interface boards, and power supplies, and they perform the electrical safety checks, performance assurance, and NIBP calibration that Philips calls for at least once every two years. Before a unit ships, we confirm the installed software and mainboard revision so you know whether it supports new-generation transducers and extended trace memory, and whether the J.30.58 NBP issue applies. We also stock wired and cableless Avalon transducers, Avalon CL base stations, DECG and IUP accessories, belts, NIBP cuffs, SpO₂ sensors, and fetal recorder paper. If your facility is retiring or consolidating fetal monitors, IPR Medical buys used FM50 units and Avalon transducers.

IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon FM50 Fetal Monitor. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Masimo, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips, Masimo, or Nellcor.

Weight 20 lbs
Dimensions 7 × 17 × 15 in
Product Condition

,

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips Avalon FM50 Fetal Monitor. The sections below cover the most commonly requested components with OEM part numbers where confirmed by Philips documentation. Some accessories are not available in every region, and interface and assembly SKUs vary by hardware revision. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


Wired Fetal Transducers — Current Generation

Toco+ MP Transducer (867245) Toco, maternal pulse (Smart Pulse), and ECG/IUP adapter connection; requires Avalon software L.3x.xx; OEM P/N 867245
Ultrasound Transducer (867246) External ultrasound fetal heart rate; see FDA note on the Description Tab regarding transducer software L.01.04; OEM P/N 867246
ECG/IUP Transducer (867247) Connects DECG, MECG, or IUP adapter cables; replaces the M2738A patient module; OEM P/N 867247
Toco MP Transducer (867248) External Toco with maternal pulse; replaces M2734B; OEM P/N 867248
Toco+ Transducer (867249) External Toco with ECG/IUP adapter connection; replaces M2735A; OEM P/N 867249

Wired Fetal Transducers — Previous Generation

Avalon Toco Transducer (M2734A) External Toco; still supported by the FM50; OEM P/N M2734A
Avalon Toco MP Transducer (M2734B) External Toco with maternal pulse; OEM P/N M2734B
Avalon Toco+ Transducer (M2735A) External Toco plus DECG, MECG, or IUP via adapter cable; OEM P/N M2735A
Avalon US Transducer (M2736A / M2736AA) External ultrasound fetal heart rate; OEM P/N M2736A or M2736AA
ECG/IUP Patient Module (M2738A) DECG, MECG, or IUP input module; OEM P/N M2738A
Remote Event Marker (989803143411) Patient-activated event marker for fetal movement annotation; OEM P/N 989803143411

Avalon CL Cableless System

Avalon CL Base Station (866074) Order option K30 (red connector, front fetal socket), K40 (black connector, rear telemetry socket), or K60 (charging station); OEM P/N 866074
Avalon CL Toco+ MP Transducer (866075) Cableless Toco with maternal pulse and ECG/IUP capability; OEM P/N 866075
Avalon CL Ultrasound Transducer (866076) Cableless ultrasound fetal heart rate; OEM P/N 866076
Avalon CL ECG/IUP Transducer (866077) Cableless DECG, MECG, or IUP; OEM P/N 866077
Avalon CL Wide Range Pod (866487) Extends cableless range over the hospital WLAN; OEM P/N 866487
IntelliVue CL SpO₂ Pod (865215) Patient-worn cableless maternal SpO₂; OEM P/N 865215
IntelliVue CL NBP Pod (865216) Patient-worn cableless maternal NIBP; OEM P/N 865216
Avalon CL Battery Replacement Kit (989803184861) Battery, opening tool, and two O-ring seals for CL transducers; OEM P/N 989803184861
Avalon CL Wide Range Battery Kit (989803196421) Replacement battery for the CL Wide Range Pod; OEM P/N 989803196421
Avalon CL Belt Clip, kit of 10 (989803184851) Belt clips for CL transducers; OEM P/N 989803184851
Avalon CL Connector Caps, kit of 10 (989803184841) Connector caps for CL transducers; OEM P/N 989803184841
Avalon CTS Interface Cable Interface cable connecting an Avalon CTS base station to the monitor. Contact IPR Medical for the specific OEM part number matching your connector (front or rear).

DECG and IUP Accessories

DECG Reusable Leg Plate Adapter Cable (989803137651) Philips DECG solution with flushing port; not compatible with QwikConnect Plus accessories; OEM P/N 989803137651
DECG Leg Attachment Electrode (989803139771) For the DECG leg plate adapter cable; OEM P/N 989803139771
DECG Fetal Scalp Electrode, Single Spiral (989803137631) Single-use fetal scalp electrode; OEM P/N 989803137631
Reusable Koala IUP Adapter Cable (989803143931) Connects an IUP catheter to the Toco+ transducer or patient module; OEM P/N 989803143931

MECG Accessories

MECG Reusable Adapter Cable (M1363A) Maternal ECG adapter cable; OEM P/N M1363A
Foam ECG Electrodes, Snap-Fit (40493D/E) Disposable electrodes for the MECG adapter cable; OEM P/N 40493D/E

Belts, Clips, and Gel

Reusable Belt, 2.4 in, 5 Belts (M4602A) Gray, water-resistant transducer belts; OEM P/N M4602A
Reusable Belt, 2.4 in x 49 ft Roll (M4603A) Gray, water-resistant belt roll; OEM P/N M4603A
Reusable Belt, 1.3 in x 49 ft Roll (M4601A) Gray, water-resistant belt roll; OEM P/N M4601A
Reusable Belt, 2.0 in, 5 Belts (M1562B) Gray, water-resistant transducer belts; OEM P/N M1562B
Disposable Belt, 2.4 in, Pack of 100 (M2208A) Yellow, water-resistant single-use belts; OEM P/N M2208A
Belt Buttons, Kit of 10 (M1569A) For previous-generation M273xA wired transducers; OEM P/N M1569A
Belt Clips for Wired Smart Transducers, Kit of 6 (989803143401) OEM P/N 989803143401
Ultrasound Gel, 12 Bottles (40483A) Coupling gel for ultrasound transducers; OEM P/N 40483A
Cable Management Kit (989803148841) OEM P/N 989803148841

NIBP Cuffs and Tubing

Comfort Care Small Adult Cuff (M1573A) Reusable 2-piece cuff, 8.1–11.0 in limb circumference; OEM P/N M1573A
Comfort Care Adult Cuff (M1574A) Reusable 2-piece cuff, 10.6–13.8 in limb circumference; OEM P/N M1574A
Comfort Care Large Adult Cuff (M1575A) Reusable 2-piece cuff, 13.4–16.9 in limb circumference; OEM P/N M1575A
Comfort Care Adult Thigh Cuff (M1576A) Reusable 2-piece cuff, 16.5–21.3 in limb circumference; OEM P/N M1576A
Comfort Care Cuff Kit, 4 Adult Sizes (M1578A) OEM P/N M1578A
Easy Care 1-Piece Reusable Cuffs (M4554B–M4559B) Small adult through adult thigh sizes; single cuffs or packs of 5. Contact IPR Medical to match the size to your patient population.
Gentle Care Single-Patient-Use Cuffs (M4574B–M4579B) Small adult through adult thigh sizes. Contact IPR Medical to match the size to your patient population.
NIBP Interconnect Tubing, 4.9 ft (M1598B) Required for all listed cuffs; OEM P/N M1598B
NIBP Interconnect Tubing, 9.8 ft (M1599B) Required for all listed cuffs; OEM P/N M1599B

SpO₂ Sensors and Cables

Philips Reusable Adult Finger Sensor (M1191B) 6.6 ft cable, patients over 110 lbs; OEM P/N M1191B
Philips Reusable Adult Finger Sensor, Long (M1191BL) 9.8 ft cable; OEM P/N M1191BL
Philips Adult Clip Sensor (M1196A) 9.8 ft cable, patients over 88 lbs; OEM P/N M1196A
Philips Adult Clip Sensor (M1196S) 6.6 ft cable, patients over 88 lbs; OEM P/N M1196S
Philips Ear Sensor (M1194A) 4.9 ft cable, adult patients over 88 lbs; OEM P/N M1194A
SpO₂ Extension Cable, 6.6 ft (M1941A) For Philips reusable sensors and adapter cables; OEM P/N M1941A
SpO₂ Adapter Cable (M1943A / M1943AL) For Philips and Nellcor disposable sensors; 3.6 ft (M1943A) or 9.8 ft (M1943AL)
Masimo LNC MP10 Patient Cable (989803148221) Adapter cable for Masimo LNCS sensors; OEM P/N 989803148221
Masimo LNCS DC-I Adult Reusable Sensor (989803148281) OEM P/N 989803148281

Maternal Temperature

Tympanic Thermometer (866149) Optional maternal temperature measurement; not for use in private households; OEM P/N 866149
Tympanic Temperature Probe (989803180831) OEM P/N 989803180831
Disposable Probe Covers, 22 Boxes of 96 (989803179381) OEM P/N 989803179381

Recorder Paper

Fetal Recorder Paper, U.S./Canada/Asia (M1910A) 30–240 bpm FHR scale, red/orange grid, mmHg; case of 40 packs, 150 pages each; OEM P/N M1910A
Fetal Recorder Paper, Europe (M1911A) 50–210 bpm FHR scale, green grid, mmHg and kPa; OEM P/N M1911A
Fetal Recorder Paper, Japan (M1913A) 50–210 bpm FHR scale, green grid, mmHg; OEM P/N M1913A

Interface Options and Field-Replaceable Units

LAN/RS232 System Interface Slot 01 board for OB TraceVue or IntelliSpace Perinatal connection. Contact IPR Medical for the specific OEM part number matching your hardware revision.
Dual PS/2, Dual MIB/RS232, Quad USB, and Flexible Nurse Call Interfaces Slot 02 option boards for input devices, external touch display, bar code readers, or nurse call. Contact IPR Medical for the specific OEM part number matching your configuration.
Touchscreen Display, Recorder, Mainboard, and Power Supply Assemblies Monitor-level FRUs. Contact IPR Medical for the specific OEM part number matching your hardware revision.

IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon FM50 Fetal Monitor. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.