Philips Compatible M1356A Fetal Ultrasound Transducer | Series 50
This is an aftermarket-compatible wide-beam Doppler ultrasound transducer designed to function as a direct replacement for the M1356A fetal ultrasound transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It is applied externally to the maternal abdomen and uses a wide-beam Doppler ultrasound element to detect fetal heart sounds, which the host monitor then processes through its auto-correlation algorithm to produce a continuous fetal heart rate (FHR) trace. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.
| Device Type | Aftermarket-compatible external wide-beam Doppler ultrasound transducer for fetal heart rate (FHR) |
| Replaces / Cross Reference | M1356A fetal ultrasound transducer (also referenced as part 80310120) |
| Compatible Monitors | Philips Series 50 A (M1351A Single and Dual Ultrasound Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 series fetal monitors |
| Patient Population | Antepartum (from approximately 20–25 weeks gestation) and intrapartum monitoring |
| Connector | Keyed round multi-pin connector compatible with the US, US1, or US2/ECG socket on the Series 50 monitor |
| Mounting | Snap-clip belt fixing onto compatible reusable fetal monitoring belts (e.g., M1562A); transducer knob adapter (M1356-43201) optional |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact us at 855-477-8866 or cs@iprmed.com.
Compatible Fetal Ultrasound Transducer for Philips Series 50 (M1356A) — Specifications
| Sold By | IPR Medical — aftermarket-compatible part; not manufactured by, affiliated with, or endorsed by Philips |
| Replaces / Cross Reference | M1356A fetal ultrasound transducer (also referenced as part 80310120) |
| Device Type | External wide-beam Doppler ultrasound transducer for non-invasive fetal heart rate monitoring |
| Intended Function | External, non-invasive monitoring of fetal heart rate (FHR) using wide-beam Doppler ultrasound, applied to the maternal abdomen during antepartum and intrapartum monitoring |
| Doppler Type | Continuous-wave wide-beam Doppler with multiple piezoelectric crystals; auto-correlation FHR signal processing performed by the host monitor |
| Compatible Host Monitors | Philips Series 50 A (M1351A Single Ultrasound and Dual Ultrasound Twins), Series 50 IP-2 (M1353A); also used as a service replacement on earlier Philips/HP M1350 series fetal monitors |
| Monitor Sockets Used | US socket (Single Ultrasound model); US1 and US2 sockets (Dual Ultrasound Twins); US1 and US2/ECG sockets (M1353A IP-2) |
| Mode Identification | Identified by the host monitor as ultrasound mode automatically when connected; the host selects the correct operating mode without operator action |
| Signal Quality Reporting | Per-channel signal quality indicator on the host monitor: green (optimum), yellow (fair to potentially poor), red (unacceptable) |
| Belt Attachment | Integrated snap-clip designed to slide on compatible reusable transducer belts (e.g., M1562A); optional fixing-button adapter (M1356-43201) for the buttoned belt-attachment style |
| Patient Contact Material | Latex-free; designed for use with standard ultrasound coupling gel (e.g., Aquasonic / part 40483A) |
| Compatible Accessories | Reusable transducer belt M1562A; transducer knob adapter M1356-43201; ultrasound coupling gel 40483A |
| Cleaning & Disinfection | Surface clean and disinfect per the host system’s instructions for use; do not immerse the transducer in liquid while connected to the monitor; do not steam-sterilize |
| Regulatory Classification | Accessory to a Class II fetal ultrasonic monitor under 21 CFR 884.2660 (FDA Obstetrics/Gynecology panel); host monitor cleared via 510(k) by its original manufacturer |
| FDA Device Corrections | An FDA Class 2 device recall record exists for the original Ultrasound Transducer (M1356A) in the FDA Medical Device Recalls Database (Recall Event ID 175942). This recall affects original-manufacturer transducers and lots — not this aftermarket-compatible part — but is referenced here for fleet awareness. See the Description Tab for further detail and links to the FDA’s official record. |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Overview
This is an aftermarket-compatible external Doppler ultrasound transducer offered by IPR Medical as a direct replacement for the M1356A fetal ultrasound transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs). It is designed for use with the Series 50 A (M1351A) Single Ultrasound and Dual Ultrasound Twins models and the Series 50 IP-2 (M1353A) intrapartum model, and can also be used as a service replacement on earlier Philips/HP M1350 series monitors. The transducer is applied externally to the maternal abdomen and uses wide-beam Doppler ultrasound to detect fetal heart sounds; the host monitor processes that signal through an auto-correlation algorithm to produce a continuous fetal heart rate (FHR) trace on its integrated thermal recorder. The compatible part is intended for antepartum monitoring from approximately 20 to 25 weeks of gestation through term and, in combination with the M1353A, may also be used during labor and delivery alongside DECG and IUP measurements. This is a compatible aftermarket part sold and supported by IPR Medical and is not manufactured by, affiliated with, or endorsed by Philips.
Connector, Cable, and Belt Attachment
The compatible M1356A-style transducer terminates in a keyed round multi-pin connector that mates with the dedicated US, US1, or US2/ECG socket on the front face of the Series 50 monitor. On the M1351A Single Ultrasound model, the transducer connects to the single US socket; on the M1351A Dual Ultrasound Twins model, two transducers are used — one in each of the US1 and US2 sockets — to monitor both fetuses simultaneously. On the M1353A Series 50 IP-2, the US2/ECG socket can accept either an ultrasound transducer (for twin external monitoring) or a DECG legplate (for direct fetal scalp ECG monitoring). Once connected, the host monitor automatically detects the transducer type and selects the correct operating mode without operator action. The transducer body includes a snap-shut clip that secures it to a compatible reusable abdominal belt and is designed to slide along the belt for easy repositioning during monitoring; an optional transducer knob adapter is available where the buttoned belt-attachment style is preferred.
Doppler Operation and Signal Quality
The compatible transducer is a wide-beam Doppler device that uses a multi-element piezoelectric crystal array to emit a broad ultrasound beam through the maternal abdominal wall and to receive Doppler-shifted echoes returning from the moving fetal heart. The host Series 50 monitor performs auto-correlation processing on the received signal to extract a stable beat-to-beat fetal heart rate even when the transducer is not perfectly centered over the fetal heart, which simplifies clinical placement. During monitoring, the per-channel signal quality indicator on the monitor’s display shows green for an optimum signal, yellow for fair-to-poor signal, and red for an unacceptable signal; brief fluctuations between yellow and green can result from fetal movement and do not necessarily mean the transducer requires repositioning. A consistently red indicator typically signals a need for repositioning the transducer, reapplying coupling gel, or replacing a worn transducer. When suspected fetal demise is being investigated, clinicians should be aware that maternal heart rate can be detected by the transducer and confused with fetal heart rate, and cross-channel verification with another modality is recommended.
Compatibility with the Philips Series 50 Family
The compatible M1356A-style ultrasound transducer is designed for use with the Philips Series 50 A and Series 50 IP-2 monitors documented in the Series 50 family’s instructions for use and service guide. The Series 50 A Single Ultrasound model is configured for a single ultrasound channel; the Dual Ultrasound Twins model uses two ultrasound transducers simultaneously, one on each US channel, for twin external monitoring; and the Series 50 IP-2 (M1353A) supports a single ultrasound transducer on the primary US1 channel and a second transducer on the US2/ECG channel for external twin monitoring. The compatible transducer is also commonly used as a service replacement on the earlier Hewlett-Packard / Philips M1350 series fetal monitor lineage from which the Series 50 platform evolved. Original-manufacturer color variants of this part exist (Brown M1356-60001 and Blue M1356-60011, supplied historically to color-match different monitor cabinets); the compatible aftermarket part is interchangeable on any Series 50 ultrasound socket regardless of monitor housing color.
Use with Coupling Gel, Belts, and Disposables
External Doppler ultrasound transducers require an acoustic coupling medium between the transducer face and the maternal skin to transmit the ultrasound beam efficiently. Standard ultrasound coupling gel (e.g., Aquasonic, supplied historically with Series 50 monitors under part 40483A) is recommended for use with this compatible transducer. The transducer is held in position with a compatible reusable abdominal belt — the M1562A style remains the most common — fastened around the mother with the fixing button positioned to one side and the loose ends arranged so they remain at the patient’s side rather than under her body. Two belts are typically used when monitoring uterine activity (with a Toco transducer) and FHR simultaneously, and three belts are typical for twin and IP-2 configurations. Belts are reusable and should be cleaned per the host system’s instructions for use between patients; the transducer body itself should be wiped clean of gel after each use, surface-disinfected per the host system’s care and cleaning instructions, and never immersed in liquid while connected to the monitor.
Service, Testing, and Preventive Maintenance
The Philips Series 50 service guide defines a structured ultrasound parameter test that biomedical staff use to validate the ultrasound channel in the field. The Series 50 monitor includes a built-in Self Test, Quick Test, and Parameter Test, and the Ultrasound Parameter Test exercises the front-end ultrasound circuitry together with an attached transducer to confirm correct beat-to-beat detection. Common bench failures on aged transducers — original-manufacturer or aftermarket — include intermittent signal quality due to cable flex damage near the strain relief and at the connector backshell, reduced acoustic output from the piezoelectric assembly resulting in chronically poor signal quality even with fresh gel and good positioning, and connector pin damage from repeated insertion. The transducer is treated as a field-replaceable assembly; component-level repair of the piezoelectric element is not generally recommended, and the standard remedy for a failed transducer is replacement of the assembly. Performance verification after replacement should follow the same parameter test sequence the host system’s service guide defines for the ultrasound channel.
Service and Maintenance Considerations
The compatible M1356A-style transducer is a passive ultrasound transducer rather than a networked device and has no software, cybersecurity, or EMR integration of its own; data transmission, alerts, trend storage, and integration with obstetrical surveillance systems are handled by the host Series 50 monitor and its optional Combined Interface Module or Modem Interface Module. From a clinical engineering perspective the transducer should be inspected at each preventive maintenance interval for housing cracks, wear of the patient-contact face, cable jacket integrity, strain-relief integrity at both the transducer body and the monitor connector, and connector pin condition. Because the transducer is used directly on the maternal abdomen with conductive coupling gel, the safety testing schedule that applies to the host monitor’s patient-applied parts should also be carried through to the transducer when it is the suspected source of leakage current or signal quality issues. IPR Medical’s biomed team can support facilities that need bench testing, evaluation, or replacement of compatible transducers as part of fleet maintenance on Philips Series 50 monitors.
FDA Device Corrections and Safety Bulletins
A Class 2 medical device recall record exists in the FDA Medical Device Recalls Database for the original Ultrasound Transducer (M1356A) under Recall Event ID 175942. Class 2 indicates a situation in which use of, or exposure to, the device may cause temporary or medically reversible adverse health consequences, and the probability of serious adverse health consequences is remote. This recall affects original-manufacturer transducers and specific lots identified by the recalling firm — it does not affect this aftermarket-compatible replacement part offered by IPR Medical — but it is referenced here so clinical engineering teams responsible for Philips Series 50 fleets are aware of the active record. IPR Medical recommends that those teams review the FDA’s official record for this recall directly to confirm the affected lot or date ranges, the recalling firm’s reference and reason, the specific corrective action requested, and the current status of the recall, because these details may be updated by FDA after the date of this listing. Facilities operating Philips Series 50 fetal monitors should also review the broader Philips fetal-monitoring transducer safety communications referenced on the original manufacturer’s customer support portal, including any field correction or service notices that affect transducers refurbished beyond their useful life.
Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.
FDA resources for further review:
FDA Medical Device Recalls Database |
FDA Medical Device Safety
IPR Medical — Buy, Sell, Repair, and Parts
IPR Medical buys, sells, repairs, and stocks parts and accessories for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers offered as direct replacements for the M1356A. Whether your facility needs a single replacement transducer to bring a Series 50 A or Series 50 IP-2 back into service, additional transducers for a Labor and Delivery floating cart, or evaluation and repair of an existing transducer that is producing intermittent or poor signal quality, IPR Medical’s biomed team can support the request. We also buy back surplus Series 50 monitors and accessories from facilities decommissioning older fetal monitor fleets, and can supply matching Toco transducers, DECG legplates, MECG transducers, patient modules, and recorder paper to keep existing units in service. Reach out for compatibility verification against your specific Series 50 configuration, fleet sourcing for multi-bed deployments, and service questions on the host monitor.
IPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
| Weight | 0.6 lbs |
|---|---|
| Dimensions | 4 × 4 × 4 in |
| Product Condition |
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips Series 50 fetal monitor family on which the M1356A-compatible fetal ultrasound transducer is used. The sections below cover the most commonly requested companion components with reference part numbers where confirmed by Series 50 system documentation. Some accessory SKUs vary by monitor configuration (Single Ultrasound, Dual Ultrasound Twins, IP-2), region, and revision, so part numbers should be verified for your specific monitor before ordering. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Heart Rate and Activity Transducers
| Compatible Fetal Ultrasound Transducer (M1356A) | Aftermarket-compatible wide-beam Doppler ultrasound transducer for fetal heart rate; replaces the M1356A. |
| Compatible External Toco Transducer (M1355A) | Aftermarket-compatible strain-gauge external tocodynamometer for uterine activity; replaces the M1355A. |
| DECG Transducer / Legplate (M1357A) | Direct fetal ECG legplate for use with fetal scalp electrodes on the Series 50 IP-2 (M1353A). |
| MECG Transducer (M1359A) | Maternal ECG transducer for the Series 50 IP-2 US2/ECG socket. |
| DECG/MECG Patient Module (M1364A) | Patient-worn module that accepts DECG legplate adapter cable M1362B and MECG adapter cable M1363A. |
Belts and Belt Accessories
| Reusable Transducer Belt (M1562A) | Standard reusable abdominal belt for securing the ultrasound and Toco transducers to the maternal abdomen; supplied two with Series 50 A Single Ultrasound and three with Twins / IP-2 configurations. |
| Transducer Knob Adapter (M1356-43201) | Optional fixing-button adapter for attaching the ultrasound or Toco transducer to the abdominal belt via a buttoned mounting style. |
DECG / MECG Cables and Electrodes
| DECG Legplate Adapter Cable (M1362B) | Adapter cable that connects the M1357A DECG legplate to the M1364A patient module on the Series 50 IP-2. |
| MECG Adapter Cable (M1363A) | Adapter cable that connects MECG electrodes to the M1364A patient module. |
| Disposable Spiral Scalp Electrode, Single (15133D) | Single-spiral fetal scalp electrode (US configuration) used with M1353A IP-2 monitors. |
| Disposable Spiral Scalp Electrode, Double (15133E) | Double-spiral fetal scalp electrode (Europe configuration) used with M1353A IP-2 monitors. |
Coupling Gel and Disposables
| Aquasonic Ultrasound Coupling Gel (40483A) | Standard ultrasound coupling gel supplied historically with Series 50 monitors; required for use with the M1356A-compatible ultrasound transducer. |
Recorder Paper
| Series 50 Trace Paper, USA / Canada (M1910A) | Thermal Z-fold recorder paper for the Series 50 internal recorder; US/Canada scaling. |
| Series 50 Trace Paper, Europe (M1911A) | Thermal Z-fold recorder paper for the Series 50 internal recorder; European scaling. |
| Series 50 Trace Paper, Japan (M1913A) | Thermal Z-fold recorder paper for the Series 50 internal recorder; Japan scaling. |
Remote Event Marker and Interface Modules
| Remote Event Marker (15249A) | Patient-held event marker that connects to the dedicated event marker socket on the Series 50 monitor. |
| Combined Interface Module | Optional add-on interface module providing RS232 serial, NIBP monitor, FSpO₂, and barcode reader connectivity. Contact IPR Medical for the specific part number matching your Series 50 revision. |
| Modem Interface Module | Optional add-on module supporting trace transmission to obstetrical surveillance systems via a PCMCIA modem. Contact IPR Medical for the specific part number matching your Series 50 revision. |
Field-Replaceable Boards (Series 50 Host Monitor)
| Front End Board, M1351A (M1353-66501 / M1353-66511) | Front-end signal acquisition board for M1351A Series 50 A monitors; revision varies by build. |
| Front End Board, M1353A (M1353-66512 / M1350-66517) | Front-end signal acquisition board for M1353A Series 50 IP-2 monitors; revision varies by build. |
| Power Supply Board (M1353-66502) | Mains and battery power supply board for the Series 50 chassis. |
| CPU Board (M1353-66503 / M1353-66513) | Main CPU board for the Series 50 platform; revision varies by build and software level. |
| Display Board (M1350-66520) | Front-panel digital display board. |
| Recorder Interface Board (M1353-66510) | Interface board for the integrated thermal strip-chart recorder. |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.