IPR Medical

Philips M1194AL Compatible Adult Ear Clip SpO2 Sensor, Philips FAST, 9.8 ft (3.0 m)

$100.00

The M1194AL compatible adult ear clip SpO2 sensor (SKU SS-024-AE30) is a reusable aftermarket replacement (not OEM) with an ear clip design and a 9.8 ft (3.0 m) cable, for use with the SpO2 technology shown in the table below.

Sensor Type Ear Clip
Patient Size Adult
SpO2 Technology Philips FAST
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Replaces Philips M1194AL

Works with: the monitor models listed in the Specifications tab. Browse more SpO2 sensors and cables.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors and pulse oximetry accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: SS-024-AE30 Categories: , Tags: ,
Send In Philips M1194AL Compatible Adult Ear Clip SpO2 Sensor, Philips FAST, 9.8 ft (3.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SS-024-AE30
Replaces OEM Part Philips M1194AL
Category Cables & Sensors > SpO2
Sensor Type Ear Clip
Patient Size Adult
SpO2 Technology Philips FAST
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Goldway G30, G40
Mindray / Datascope V12
Philips 862108, 862231, 862439, 862472, 862474 C3, 863063 VM4, 863064, 863065, 863066, 863068, 863071, 863071 VS3, 863072, 863073, 863074, 863077, 863080, 863081, 863082, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, Avalon FM20, Avalon FM30, Avalon FM40, Avalon FM50, C1, C3, Codemaster 100, HeartStart 4000, HeartStart MPx, HeartStart MRx, HeartStart XL, HeartStart XLT, Heartstream XL, IntelliVue MP5, IntelliVue MP5SC, IntelliVue MP5T, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX750, IntelliVue MX800, IntelliVue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M3, M4, M1020A, M1020B, M1350A, M1350C, M2475B, M2601A, M2601B, M2702A, M2703A, M2704A, M2705A, M3000A, M3001A, M3001A A01, M3001A A01C06, M3001A A01C12, M3001A A01C18, M3002A MMS X2, M3002A Opt. C12, M3046A (M4 chip), M3046A M3, M3500B, M3535A, M3536A, M3536M, M4735A, M4841A, M5500B, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, M8102A Opt.C12 MP2, M8105A, M8105A MP5, M8105A Opt. C12 MP5, M8105AS, M8105AT, MX4841A, MX Series, P60E, SureSigns VM1, SureSigns VM4, SureSigns VM6, SureSigns VM8, SureSigns VS2, SureSigns VS2+, SureSigns VS3, SureSigns VS4, SureSigns VSi, TRx 4851A, TRx M4841A, TRx+ M4841A, Viridia 24C, Viridia 50 XMO
Solaris NT2A, NT2C

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips M1194AL
Praymed PSG0015-L
Unimed U910-91

IPR Medical buys, sells, repairs, and stocks parts for ear clip SpO2 sensors and compatible patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the M1194AL Compatible Adult Ear Clip SpO2 Sensor?

The IPR Medical SS-024-AE30 is a compatible aftermarket (not OEM) adult ear clip SpO2 sensor that replaces OEM part M1194AL. The clip is reusable and comes on a 9.8 ft (3.0 m) cable; the SpO2 technology it is designed for is named in the Specifications table. For departments that prefer an ear clip over other sensor styles for adult patients, it offers a compatible alternative to the OEM part.


Compatible Monitor Models

Monitor compatibility for the SS-024-AE30 is set out model by model in the Compatible Monitor Models table on the Specifications tab, where the original equipment manufacturer’s models make up the bulk of the list. Select Solaris models (NT2A and NT2C) and the Mindray / Datascope V12 are on the list too. Locate your monitor in the table to confirm the match.


Design and Construction

The sensing end is an ear clip sized for adult patients, and it is attached to a 9.8 ft (3.0 m) cable. Each one is reusable and arrives in its own bag. After each patient, clean the clip and cable following facility protocol, and look for cracks, cuts, or connector damage before the next use.


When to Replace Your Adult Ear Clip SpO2 Sensor

An ear clip sensor is due for replacement when the clip no longer closes firmly or evenly, when its housing is cracked, or when the cable shows cuts, crush damage, or a stiff, kinked section. Bent pins at the monitor connector, readings that fluctuate when the cable is moved, and recurring sensor-off alarms point to the same conclusion. A known-good sensor tried on the same monitor separates a sensor fault from a monitor fault.


Cross Reference and Interchange Part Numbers

For OEM records, look up M1194AL, the part this sensor replaces. Matching aftermarket numbers from other brands are collected in the Cross Reference / Interchange Part Numbers table, which you will find on the Specifications tab.


Why Source Ear Clip SpO2 Sensors from IPR Medical?

The parts IPR Medical buys, sells, repairs, and stocks are for two kinds of equipment: patient monitors and infusion pumps. Every repair job stays in-house with our technicians, and IPR Medical is certified to ISO 9001:2015 as an independent service organization. Explore our SpO2 sensors and cables, or reach us at 855-477-8866.

IPR Medical buys, sells, repairs, and stocks parts for ear clip SpO2 sensors and compatible patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.