Philips M1943NL Compatible SpO2 Adapter Cable, for Use with Nellcor OxiMax Sensors, 9.8 ft (3.0 m)
The M1943NL compatible SpO2 adapter cable (SKU SA-024X-30) is a reusable aftermarket replacement (not OEM) with a 9.8 ft (3.0 m) cable, for use with Nellcor OxiMax sensors.
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
| Replaces | Philips M1943NL |
Works with: the monitor models listed in the Specifications tab. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors, SpO2 cables, and sensors. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SA-024X-30 |
| Replaces OEM Part | Philips M1943NL |
| Category | Cables & Sensors > SpO2 |
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Nellcor OxiMax |
| Used With | Nellcor OxiMax sensors |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Philips | Heartstream XL, IntelliVue MP2, IntelliVue MP20, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP90, IntelliVue MX450, M1020A, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, SureSigns VS2, SureSigns VS3, SureSigns VS4, VM4 |
| Philips (with Nellcor SpO2 Option) | 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, IntelliVue MP5SC, IntelliVue MP5T, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M3002A, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8105AS, M8105AT |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | M1943NL, 989803136591 |
| AMC | CB-A400-1006NL |
| Covidien | 10013514 |
| Curbell | 5565 |
| Sage | E01X-30M |
| Tenacore | TCEO-0114-1021, TE1516 |
| Unimed | U710X-43 |
IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables, sensors, and the patient monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Nellcor, or any other manufacturer or supplier named on this page. Philips, Nellcor, OxiMax, IntelliVue, SureSigns, Heartstream, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the M1943NL Compatible SpO2 Adapter Cable?
The IPR Medical SA-024X-30 is a compatible aftermarket (not OEM) SpO2 adapter cable that replaces OEM part M1943NL. Intended for use with Nellcor OxiMax sensors, it runs 9.8 ft (3.0 m) and can be reused from one patient to the next with proper cleaning.
Compatible Monitor Models
Every model on record for this adapter comes from the original equipment manufacturer, so the complete list is kept in the Compatible Monitor Models table on the Specifications tab instead of being repeated here. Some models are listed for use with the Nellcor SpO2 option; those configurations appear in a separate row, and several models show up in both rows. Check both rows for your model and its SpO2 configuration before ordering.
Design and Construction
The SA-024X-30 has a 9.8 ft (3.0 m) cable intended for use with Nellcor OxiMax SpO2 technology, and each adapter is bagged individually. Treat it as a reusable accessory: wipe it down between patients following your facility’s cleaning protocol, and look over the full length of the cable and its connectors before each use.
When to Replace Your SpO2 Adapter Cable
Pull the adapter from service when the jacket is cut or kinked, when a connector body is cracked or loose, or when either end has bent pins. Clinically, frequent sensor-off alerts, saturation numbers that vanish and return, and readings that change as the cable is flexed all point to a cable that is wearing out. To rule out the sensor or the monitor, repeat the check with a known-good adapter in place.
Cross Reference and Interchange Part Numbers
Apart from M1943NL, the OEM part it replaces, this compatible adapter is also known by OEM numbers 989803136591 and 10013514. Brand by brand, the aftermarket equivalents are laid out in the cross-reference table on the Specifications tab.
Why Source SpO2 Adapter Cables from IPR Medical?
Biomedical and materials teams can source this adapter from IPR Medical, which holds ISO 9001:2015 certification as an independent service organization and handles the buying, selling, repair, and stocking of parts for patient monitoring equipment and infusion pumps. When a repair is needed, IPR Medical technicians complete it in-house. For related parts, look through our SpO2 sensors and cables or phone 855-477-8866.
IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables, sensors, and the patient monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Nellcor, or any other manufacturer or supplier named on this page. Philips, Nellcor, OxiMax, IntelliVue, SureSigns, Heartstream, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.