Philips 989803171821 Compatible 5-Lead Telemetry ECG Leadwire, Snap, AHA, Molded, 3.0 ft (0.9 m)
The 989803171821 compatible 5-lead telemetry ECG leadwire (SKU EL-TMX5-90S-A) is a reusable aftermarket replacement (not OEM) with snap electrode ends, AHA color coding, shielded leads, a molded distal connector, and a 3.0 ft (0.9 m) length.
| Lead Count | 5-Lead |
| Electrode End | Snap |
| AHA/IEC Code | AHA |
| Cable Length | 3.0 ft (0.9 m) |
| Intended Use | Telemetry |
| Replaces | Philips 989803171821 |
Works with: the telemetry model listed in the Specifications tab. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for telemetry accessories and patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EL-TMX5-90S-A |
| Replaces OEM Part | Philips 989803171821 |
| Category | Cables & Sensors > ECG/EKG |
| Product | Telemetry ECG Leadwire |
| Lead Count | 5-Lead |
| Lead Placement | Limb + Chest Lead |
| Electrode End | Snap |
| AHA/IEC Code | AHA (RA white, LA black, LL red, RL green, V brown) |
| Distal Connector | Molded |
| Feature | Shielded |
| Lead Type | Philips MX40 |
| Cable Length | 3.0 ft (0.9 m) |
| Intended Use | Telemetry |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Philips | MX40 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | 989803171821 |
| Sage | L20-05-29S |
| Unimed | PT5-90S |
IPR Medical buys, sells, repairs, and stocks parts for telemetry ECG leadwires and the telemetry equipment they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, MX40, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the 989803171821 Compatible 5-Lead Telemetry ECG Leadwire?
The IPR Medical EL-TMX5-90S-A is a compatible aftermarket (not OEM) 5-lead telemetry ECG leadwire that replaces OEM part 989803171821. Built for limb and chest placement, it pairs snap electrode ends and AHA color coding with a molded distal connector in a 3.0 ft (0.9 m) length, and it is a reusable accessory for telemetry monitoring.
Compatible Monitor Models
The EL-TMX5-90S-A is listed for the single telemetry model shown in the Compatible Monitor Models table on the Specifications tab. Please confirm that your equipment matches that entry before ordering, or call 855-477-8866 and our team will help you check.
Design and Construction
Five leads end in snap electrode ends and follow AHA colors: RA white, LA black, LL red, RL green, and V brown. The leadwire is shielded, its leads join a molded distal connector, and the overall length is 3.0 ft (0.9 m). The lead type designation appears in the Specifications table. Being reusable, it should be cleaned per facility protocol between patients and inspected before it is reused. Each leadwire is packed one per bag.
When to Replace Your 5-Lead Telemetry ECG Leadwire
Telemetry leadwires flex constantly as patients move, so wear tends to appear first near the snaps and where the leads meet the connector. Replace the leadwire if a snap has lost its grip on the electrode, if the insulation is nicked or cracked, or if the connector shows bent pins or a damaged housing. Dropouts in the ECG signal, lead-off alerts that come and go, and noise that changes with patient movement are other common indicators.
Cross Reference and Interchange Part Numbers
No OEM numbers beyond the replaced part, 989803171821, are listed for this leadwire. Aftermarket interchange numbers appear in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source Telemetry ECG Leadwires from IPR Medical?
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps, and we are an ISO 9001:2015-certified independent service organization. Because our technicians repair and test patient monitoring equipment in-house, they can help you match telemetry leadwires to the units your staff supports. Visit our ECG cables and leadwires page, or call 855-477-8866 for help with orders, repairs, or parts.
IPR Medical buys, sells, repairs, and stocks parts for telemetry ECG leadwires and the telemetry equipment they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, MX40, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.



















