Philips M1500A Compatible 3-Lead ECG Trunk Cable, Defib-Proof, AHA, 8.2 ft (2.5 m)
The M1500A compatible 3-lead ECG trunk cable (SKU ET-3005R-AA-A) is a reusable aftermarket replacement (not OEM) with a defib-proof feature, limb lead placement, AHA designation, and an 8.2 ft (2.5 m) length.
| Lead Count | 3-Lead |
| Lead Placement | Limb Lead |
| AHA/IEC Code | AHA |
| Feature | Defib-Proof (with Resist) |
| Lead Type | AA Twin-Pin |
| Cable Length | 8.2 ft (2.5 m) |
| Replaces | Philips M1500A |
Works with: the monitor models listed in the Specifications tab. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | ET-3005R-AA-A |
| Replaces OEM Part | Philips M1500A |
| Category | Cables & Sensors > ECG/EKG |
| Product | ECG Trunk Cable |
| Lead Count | 3-Lead |
| Lead Placement | Limb Lead |
| AHA/IEC Code | AHA |
| Feature | Defib-Proof (with Resist) |
| Lead Type | AA Twin-Pin |
| Cable Length | 8.2 ft (2.5 m) |
| Intended Use | Monitoring |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Newtech | NT3A |
| Nihon Kohden | NT3B, Omnicare CMA |
| Philips | 43100A, 43110A, 43120A, 78352C, 78354A/C, 78354C, 78534C, 78834A/B/C, 78834C, 862472, 862473, 862474, 862474 C3, 862475, 862475 C3, 862478, 862478 C3, 862479, 862479 C3, 863063 VM4, 863064, 863065, 863066, 863068, 863069, 863077, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, C3, C Series, Codemaster XL, CodeMaster XL+, CX50, Efficia CM10 (863301), Efficia CM12 (863303), Efficia CM100 (863300), Efficia CM120 (863302), Efficia CM150 (863304), Envisor, EPIQ 7, HD11, HD11XE, HD15, HeartStart MRx, HeartStart XL, IE33, IntelliVue MP5, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX700 Masimo Rainbow, IntelliVue MX800, Intellivue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M2, M3, M4, M1001A, M1001B, M1002A, M1002B, M1094A, M1094B, M1165A, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1264A, M1275A, M1275A Transport, M1276A, M1280A, M1722A, M1722B, M1723A, M1723B, M2475B, M2601A, M2601B, M3000A, M3001A, M3001A Opt. C12, M3001A Opt. C18, M3002A, M3002A MMS X2, M3002A X2, M3046A, M3046A (M4 chip), M3046A M3, M3535A, M3536A, M4735A, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A MP2, M8105A MP5, Merlin, P60E, SureSigns VM3, SureSigns VM4, SureSigns VM6, SureSigns VM8, TRx4851A, V24, V24E, V26, Viridia 24, Viridia 24C |
| Smiths Medical / BCI | SurgiVet V9200 |
| Solaris | NT3C, NT3E, NT3F |
| Welch Allyn | 242, Propaq Encore 206EL |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | M1500A, 453561233921, M1540C, 989803103811 |
| AMC | CB-81385R |
| Cardinal Health / Kendall | 31285276A |
| Curbell | CBT-03JB-10CS-0121 |
| Mindray / Datascope | 0012-00-0846 |
| Pacific Medical | NEPH1500 |
| Sage | T08-03-30M |
| Tenacore | 43385 |
| Unimed | AA-2385 |
IPR Medical buys, sells, repairs, and stocks parts for ECG trunk cables, leadwires, and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, CodeMaster, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the M1500A Compatible 3-Lead ECG Trunk Cable?
The IPR Medical ET-3005R-AA-A is a compatible aftermarket (not OEM) 3-lead ECG trunk cable that replaces OEM part M1500A. A trunk cable is the link between the patient leadwires and the monitor; this one is reusable, set up for limb lead placement, AHA-designated, and 8.2 ft (2.5 m) long. It is defib-proof and intended for ECG monitoring. The leadwire type it pairs with is given in the Lead Type row of the Specifications table.
Compatible Monitor Models
The compatibility list for this 3-lead trunk cable is long and covers models from several manufacturers. Among them are select Welch Allyn models such as the Propaq Encore 206EL and 242, select Solaris models such as the NT3C, NT3E, and NT3F, the SurgiVet V9200 listed under Smiths Medical / BCI, and select Nihon Kohden and Newtech models. Every model is listed by manufacturer in the Compatible Monitor Models table on the Specifications tab, and checking your exact model there first is the surest way to order the right cable.
Design and Construction
The ET-3005R-AA-A is configured for a 3-lead limb setup and uses AHA designation. It measures 8.2 ft (2.5 m) and is listed as defib-proof. The cable is reusable; clean it between patients following your facility protocol. Packaging is one cable per bag. Match the lead type shown in the Specifications table to the leadwires already in use on your floor.
When to Replace Your 3-Lead ECG Trunk Cable
Every lead signal travels through the trunk cable, so a fault here tends to affect all three leads at once: flat or intermittent traces on every lead, lead-off alarms that persist with fresh electrodes, or noise that appears whenever the cable is flexed. On inspection, look for a cracked or kinked jacket, a damaged connector housing, and bent pins at the monitor connector. Swapping in a known-good trunk cable while keeping the same leadwires and monitor is a quick way to confirm where the fault lies.
Cross Reference and Interchange Part Numbers
OEM part M1500A is the primary reference for this compatible trunk cable, and OEM numbers 989803103811 and 453561233921 also cross-reference to it. The rest of the OEM and aftermarket interchange numbers are collected, brand by brand, in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source ECG Trunk Cables from IPR Medical?
Patient monitors and infusion pumps are the equipment IPR Medical supports every day: we buy, sell, repair, and stock their parts as an ISO 9001:2015-certified independent service organization. Because our technicians handle monitor repair and testing in-house, we can help match trunk cables and leadwires to the monitors you already run. See more ECG cables and leadwires, or call 855-477-8866 if you need a part, a repair, or help choosing a replacement cable.
IPR Medical buys, sells, repairs, and stocks parts for ECG trunk cables, leadwires, and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, CodeMaster, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.




















