Philips 989803129161 Compatible 10-Lead ECG Leadwire Set, 4 mm Banana, AHA, Individual, 2.6 ft + 3.9 ft (0.8 m + 1.2 m)
The 989803129161 compatible 10-lead ECG leadwire set (SKU EKL-PWA10-B-A) is a reusable aftermarket replacement (not OEM) with 4 mm banana electrode ends, AHA color coding, shielded leads, and lead lengths of 2.6 ft + 3.9 ft (0.8 m + 1.2 m).
| Lead Count | 10-Lead |
| Electrode End | 4 mm Banana |
| AHA/IEC Code | AHA |
| Cable Length | 2.6 ft + 3.9 ft (0.8 m + 1.2 m) |
| Lead Type | Philips Trim Series |
| Replaces | Philips 989803129161 |
Works with: the monitor models listed in the Specifications tab. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for ECG accessories and patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EKL-PWA10-B-A |
| Replaces OEM Part | Philips 989803129161 |
| Category | Cables & Sensors > ECG/EKG |
| Product | ECG Leadwire Set |
| Lead Count | 10-Lead |
| Lead Placement | Limb + Chest Lead |
| Electrode End | 4 mm Banana |
| AHA/IEC Code | AHA |
| Distal Connector | Individual |
| Feature | Shielded |
| Lead Type | Philips Trim Series |
| Cable Length | 2.6 ft + 3.9 ft (0.8 m + 1.2 m) |
| Intended Use | Monitoring |
| Lifecycle | Reusable |
| Packaging | 1 set per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Philips | CardioDynamics BioZ, M1701A, PageWriter PIM module – 989803130091, PageWriter PIM module – 989803130101, PageWriter TC70, PageWriter Touch, PageWriter Trim I, PageWriter Trim II, PageWriter Trim III, PageWriter XLE 1702A, PageWriter XLi M1700A |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | 989803129161, M1702A, M1700-69501 |
| Sage | L01-10-MSB |
| Sonosite | 32027700 |
| Unimed | PW10-LB |
IPR Medical buys, sells, repairs, and stocks parts for banana-end ECG leadwire sets and the equipment they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, PageWriter, Trim, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the 989803129161 Compatible 10-Lead ECG Leadwire Set?
The IPR Medical EKL-PWA10-B-A is a compatible aftermarket (not OEM) 10-lead ECG leadwire set that replaces OEM part 989803129161. The set combines limb and chest leads, uses 4 mm banana electrode ends, and follows AHA color coding. It is a reusable accessory intended for ECG monitoring, with lead lengths listed as 2.6 ft + 3.9 ft (0.8 m + 1.2 m).
Compatible Monitor Models
The EKL-PWA10-B-A is listed for eleven models, and every one of them appears in the Compatible Monitor Models table on the Specifications tab. Two entries include an additional part number next to the model name, and the table shows both exactly as listed. Compare your model designation with the table before ordering, or call IPR Medical at 855-477-8866 and we will help you confirm the fit.
Design and Construction
Each lead in this set terminates in a 4 mm banana electrode end, and the leads are color coded to the AHA standard. Lead lengths are listed as 2.6 ft + 3.9 ft (0.8 m + 1.2 m), the distal connector type is listed as Individual, and the leads are shielded. The lead type designation is shown in the Specifications table. Because the set is reusable, it can be cleaned between patients per facility protocol and inspected before it returns to service. It ships one set per bag.
When to Replace Your 10-Lead ECG Leadwire Set
Replace the set when a banana end no longer seats firmly, when the insulation shows cracks, cuts, or flattened sections, or when a connector housing is chipped or loose. On the tracing, a wandering or noisy baseline, intermittent lead-off messages, and artifact that follows cable movement can all point to a failing conductor. Testing with a known-good set on the same device is a quick way to separate a leadwire problem from an equipment fault.
Cross Reference and Interchange Part Numbers
Beyond OEM part 989803129161, this leadwire set cross-references to OEM number M1700-69501. Further OEM references, along with the aftermarket interchange numbers, are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source ECG Leadwires from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Repairs and testing are handled in-house by our own technicians, so our team can help you confirm the right leadwire set for your equipment before it ships. Browse our ECG cables and leadwires, or call 855-477-8866 for help with orders, repairs, or parts.
IPR Medical buys, sells, repairs, and stocks parts for banana-end ECG leadwire sets and the equipment they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, PageWriter, Trim, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.