Philips 896083021 Compatible IBP Adapter Cable, for Edwards Transducers, 13.1 ft (4.0 m)
The 896083021 compatible IBP adapter cable (SKU IBP-PH-EW40) is a reusable aftermarket replacement (not OEM) with a 13.1 ft (4.0 m) length, for use with Edwards transducers.
| Product | IBP Adapter Cable |
| Transducer Brand | Edwards |
| Cable Length | 13.1 ft (4.0 m) |
| Lifecycle | Reusable |
| Replaces | Philips 896083021 |
Works with: the monitor models listed in the Specifications tab. Browse more IBP cables and accessories.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and invasive blood pressure accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | IBP-PH-EW40 |
| Replaces OEM Part | Philips 896083021 |
| Category | Cables & Sensors > IBP |
| Product | IBP Adapter Cable |
| Transducer Brand | Edwards |
| Cable Length | 13.1 ft (4.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Contec | Patient Simulator MS400 |
| Mediblu | MM12 |
| Medica D | Logicare Series 2000 |
| Philips | 3536A, 8030A, 8040A, 78205A-D, 78341A, 78342A, 78352A, 78354C, 867030, 867033, 867036, 867039, 867040, 867041, CMS 24, Efficia CM120 (863302), HeartStart MRx, IntelliVue MMS X2, IntelliVue MMX, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MX400, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, M2, M3, M4, M1006A, M1006A/B, M1006B, M1026A, M1165A, M1166A, M1175A, M1176A, M1205A, M1350A, M1350B, M1353A, M3000A, M3001A, Merlin 1300, MX8000, MX Series, Omnicare M1006A, SureSigns VM8, Tempus Pro, V26, Viridia 24 |
| Pronk Technologies | SL-8 |
| Welch Allyn | Propaq CS |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | 896083021 |
| Edwards | 105649, PX1800, 896135021 |
| Mortara | 9293-058-60 |
| Unimed | BC-HP-ED |
| Welch Allyn | 9293-058-60 |
IPR Medical buys, sells, repairs, and stocks parts for IBP adapter cables and invasive pressure monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Edwards, or any other manufacturer or supplier named on this page. Philips, Edwards, IntelliVue, HeartStart, SureSigns, Efficia, Viridia, Omnicare, Merlin, Tempus Pro, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the 896083021 Compatible IBP Adapter Cable?
The IPR Medical IBP-PH-EW40 is a compatible aftermarket (not OEM) invasive blood pressure (IBP) adapter cable that replaces OEM part 896083021. Intended for use with Edwards transducers, this reusable cable measures 13.1 ft (4.0 m).
Compatible Monitor Models
Most of the compatibility list for OEM part 896083021 consists of the original equipment manufacturer’s own models, which you can review in the Compatible Monitor Models table on the Specifications tab. Beyond those, the list takes in the Welch Allyn Propaq CS, the Mediblu MM12, the Medica D Logicare Series 2000, the Pronk Technologies SL-8, and the Contec Patient Simulator MS400. That table is the reference to check against before you place an order.
Design and Construction
The job of the IBP-PH-EW40 is to connect an Edwards pressure transducer to the compatible equipment named in the table. The cable runs 13.1 ft (4.0 m), is made for reuse, and ships one per bag. Clean it between patients according to your facility protocol, and inspect it before it goes back into service.
When to Replace Your IBP Adapter Cable
Typical signs that this adapter cable needs replacing are a pressure trace that looks damped or erratic, an IBP channel that will not zero or keeps losing the transducer, and values that shift when someone touches the cable. Check the jacket along its full length for cuts and kinks, look at the transducer-end connector for cracks or a loose fit, and inspect the monitor connector for bent pins. A known-good adapter cable on the same setup will show quickly whether the cable is the problem.
Cross Reference and Interchange Part Numbers
The IBP-PH-EW40 takes the place of OEM part 896083021. OEM numbers 105649, PX1800, and 9293-058-60 also cross-reference to it; every interchange number, the aftermarket equivalent included, is grouped by brand in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source IBP Cables from IPR Medical?
Need another IBP adapter cable for an Edwards transducer setup? IPR Medical sells them as part of a business that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps, and its repairs are performed in-house by its own technicians. The company operates as an ISO 9001:2015-certified independent service organization; call 855-477-8866 to confirm the right adapter cable for your Edwards transducers, or browse our IBP cables and accessories.
IPR Medical buys, sells, repairs, and stocks parts for IBP adapter cables and invasive pressure monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Edwards, or any other manufacturer or supplier named on this page. Philips, Edwards, IntelliVue, HeartStart, SureSigns, Efficia, Viridia, Omnicare, Merlin, Tempus Pro, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews