GE Healthcare 2106397-001 / 421932-001 Compatible 6-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Individual, 3 ft (0.9 m), AHA
The GE Healthcare 2106397-001 compatible 6-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 6-lead grabber set (also sold as 421932-001), built to match the original’s fit, form, and function.
| Leads | 6 (4 Limb + 2 Chest) |
| Trunk-End Connector | GE Multi-Link, Individual Leads |
| Patient-End Connector | Grabber/Pinch Clips |
| Lead Length | 3 ft (0.9 m) |
| Color Code | AHA (US) |
| Patient Size | Adult/Pediatric |
| Construction | Shielded, Reusable, Latex-Free |
Works with: GE CARESCAPE B450, B650, B850, and CARESCAPE ONE monitors, and ApexPro CH telemetry. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | EL-MQS6-90G-A |
| OEM Reference | GE Healthcare 2106397-001 / 421932-001 |
| Lead Type | GE Multi-Link |
| Lead Count | 6 Leads |
| Lead Placement | Limb + Chest (4 Limb, 2 Chest) |
| Color Code | AHA (US) |
| Trunk-End Connector | GE Multi-Link, Individual Leads |
| Patient-End Connector | Grabber/Pinch Clip |
| Leadwire Length | 3 ft (0.9 m), Limb and Chest Leads |
| Shielding | Shielded |
| Patient Size | Adult/Pediatric |
| Lifecycle | Reusable |
| Latex-Free | Yes |
| Sterile | No |
| Packaging | 1 per Bag |
| Weight | 0.3 lbs |
Compatible Monitor Models
| Manufacturer | Compatible Model |
| GE Healthcare | CARESCAPE B450 |
| GE Healthcare | CARESCAPE B650 |
| GE Healthcare | CARESCAPE B850 |
| GE Healthcare | CARESCAPE ONE |
| GE Healthcare / Marquette | ApexPro CH Telemetry |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| GE Healthcare | 2106397-001 |
| Marquette | 2106397-002, 2106397-003 |
| Marquette | 421932-001, 421932-002, 421932-003 |
| AMC | LW-3410029/6A |
| AMC | LW-3400029/6A |
| Curbell | LDW-06BD-29AM-0100, LDW-06BD-51AM-0100, LDW-06BD-MXAM-0100 |
| Tenacore | 40300-30-6A |
IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE patient monitors and ApexPro telemetry. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the GE 2106397-001 Compatible 6-Lead ECG Leadwire?
The GE Healthcare 2106397-001 compatible 6-lead ECG leadwire is a reusable, aftermarket lead set for GE’s Multi-Link ECG system. It carries cardiac signals from six surface electrodes, four limb leads and two chest leads, to a Multi-Link trunk cable and on to the monitor or telemetry transmitter. Its two chest leads provide an additional precordial view compared with a 5-lead set, supporting more complete arrhythmia and ST-segment surveillance in critical care, telemetry, and step-down units. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 2106397-001 and 421932-001 lead sets.
Compatible Monitor Models
This compatible grabber-end 6-lead set is confirmed for use with GE CARESCAPE B450, B650, B850, and CARESCAPE ONE patient monitors, and with GE ApexPro CH telemetry. It connects through a GE Multi-Link trunk cable configured for 6-lead monitoring. Confirm that the trunk cable in service accepts six leads before switching from a 3- or 5-lead setup.
Design and Construction
Each of the six leads is 3 ft (0.9 m) long and shielded to limit interference from nearby electrical equipment. The trunk end of every lead has its own Multi-Link connector that plugs into its labeled position on the trunk cable. The patient end has a spring-loaded grabber/pinch clip. Because the clip opens wide, it attaches to both tab electrodes and snap electrodes, which makes this version a flexible choice for units that stock more than one electrode style. The leads follow the AHA color code. The set is latex-free, non-sterile, rated for adult and pediatric patients, weighs about 0.3 lbs, and ships one per bag.
When to Replace Your GE 6-Lead Grabber Leadwire
Grabber clips take the most wear on a reusable lead set, since their springs weaken with repeated opening and closing. Replace the set when a clip no longer holds the electrode firmly, when one or more leads show artifact or intermittent “lead fail” alarms despite good electrode prep, or when you notice cracked jacketing near the clips or connectors, exposed shielding, worn color bands, or a Multi-Link connector that no longer seats securely. Because the 6-lead set is chosen for its extra chest view, a failing chest lead defeats the purpose of the configuration, so prompt replacement keeps monitoring reliable.
Cross Reference and Interchange Part Numbers
This compatible 6-lead grabber leadwire, IPR Medical SKU EL-MQS6-90G-A, cross-references to GE Healthcare part number 2106397-001 and to Marquette part numbers 2106397-002, 2106397-003, 421932-001, 421932-002, and 421932-003. It also interchanges with AMC LW-3410029/6A and LW-3400029/6A, Curbell LDW-06BD-29AM-0100, LDW-06BD-51AM-0100, and LDW-06BD-MXAM-0100, and Tenacore 40300-30-6A. The OEM -001 numbers are 29 in, -002 are 51 in, and -003 are mixed lengths, so confirm the 3 ft (0.9 m) length suits your application. For snap-style electrodes only, IPR Medical also stocks the compatible 2106395-001 6-lead snap set.
Why Source ECG Leadwires from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. Our compatible Multi-Link leadwires come in 3-, 5-, and 6-lead configurations with snap and grabber ends, so biomedical and materials teams can standardize accessories across GE CARESCAPE and ApexPro fleets at lower cost than OEM. Our team can help match lead sets to your trunk cables and support your monitors with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE patient monitors and ApexPro telemetry. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews