IPR Medical

GE Healthcare 2106397-001 / 421932-001 Compatible 6-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Individual, 3 ft (0.9 m), AHA

$60.00

The GE Healthcare 2106397-001 compatible 6-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 6-lead grabber set (also sold as 421932-001), built to match the original’s fit, form, and function.

Leads 6 (4 Limb + 2 Chest)
Trunk-End Connector GE Multi-Link, Individual Leads
Patient-End Connector Grabber/Pinch Clips
Lead Length 3 ft (0.9 m)
Color Code AHA (US)
Patient Size Adult/Pediatric
Construction Shielded, Reusable, Latex-Free

Works with: GE CARESCAPE B450, B650, B850, and CARESCAPE ONE monitors, and ApexPro CH telemetry. Browse more ECG/EKG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: EL-MQS6-90G-A Categories: , Tags: , ,
Send In GE Healthcare 2106397-001 / 421932-001 Compatible 6-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Individual, 3 ft (0.9 m), AHA for Repair
Product Type Compatible Replacement (Aftermarket, Not OEM)
IPR Medical SKU EL-MQS6-90G-A
OEM Reference GE Healthcare 2106397-001 / 421932-001
Lead Type GE Multi-Link
Lead Count 6 Leads
Lead Placement Limb + Chest (4 Limb, 2 Chest)
Color Code AHA (US)
Trunk-End Connector GE Multi-Link, Individual Leads
Patient-End Connector Grabber/Pinch Clip
Leadwire Length 3 ft (0.9 m), Limb and Chest Leads
Shielding Shielded
Patient Size Adult/Pediatric
Lifecycle Reusable
Latex-Free Yes
Sterile No
Packaging 1 per Bag
Weight 0.3 lbs

Compatible Monitor Models

Manufacturer Compatible Model
GE Healthcare CARESCAPE B450
GE Healthcare CARESCAPE B650
GE Healthcare CARESCAPE B850
GE Healthcare CARESCAPE ONE
GE Healthcare / Marquette ApexPro CH Telemetry

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
GE Healthcare 2106397-001
Marquette 2106397-002, 2106397-003
Marquette 421932-001, 421932-002, 421932-003
AMC LW-3410029/6A
AMC LW-3400029/6A
Curbell LDW-06BD-29AM-0100, LDW-06BD-51AM-0100, LDW-06BD-MXAM-0100
Tenacore 40300-30-6A

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE patient monitors and ApexPro telemetry. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the GE 2106397-001 Compatible 6-Lead ECG Leadwire?

The GE Healthcare 2106397-001 compatible 6-lead ECG leadwire is a reusable, aftermarket lead set for GE’s Multi-Link ECG system. It carries cardiac signals from six surface electrodes, four limb leads and two chest leads, to a Multi-Link trunk cable and on to the monitor or telemetry transmitter. Its two chest leads provide an additional precordial view compared with a 5-lead set, supporting more complete arrhythmia and ST-segment surveillance in critical care, telemetry, and step-down units. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 2106397-001 and 421932-001 lead sets.


Compatible Monitor Models

This compatible grabber-end 6-lead set is confirmed for use with GE CARESCAPE B450, B650, B850, and CARESCAPE ONE patient monitors, and with GE ApexPro CH telemetry. It connects through a GE Multi-Link trunk cable configured for 6-lead monitoring. Confirm that the trunk cable in service accepts six leads before switching from a 3- or 5-lead setup.


Design and Construction

Each of the six leads is 3 ft (0.9 m) long and shielded to limit interference from nearby electrical equipment. The trunk end of every lead has its own Multi-Link connector that plugs into its labeled position on the trunk cable. The patient end has a spring-loaded grabber/pinch clip. Because the clip opens wide, it attaches to both tab electrodes and snap electrodes, which makes this version a flexible choice for units that stock more than one electrode style. The leads follow the AHA color code. The set is latex-free, non-sterile, rated for adult and pediatric patients, weighs about 0.3 lbs, and ships one per bag.


When to Replace Your GE 6-Lead Grabber Leadwire

Grabber clips take the most wear on a reusable lead set, since their springs weaken with repeated opening and closing. Replace the set when a clip no longer holds the electrode firmly, when one or more leads show artifact or intermittent “lead fail” alarms despite good electrode prep, or when you notice cracked jacketing near the clips or connectors, exposed shielding, worn color bands, or a Multi-Link connector that no longer seats securely. Because the 6-lead set is chosen for its extra chest view, a failing chest lead defeats the purpose of the configuration, so prompt replacement keeps monitoring reliable.


Cross Reference and Interchange Part Numbers

This compatible 6-lead grabber leadwire, IPR Medical SKU EL-MQS6-90G-A, cross-references to GE Healthcare part number 2106397-001 and to Marquette part numbers 2106397-002, 2106397-003, 421932-001, 421932-002, and 421932-003. It also interchanges with AMC LW-3410029/6A and LW-3400029/6A, Curbell LDW-06BD-29AM-0100, LDW-06BD-51AM-0100, and LDW-06BD-MXAM-0100, and Tenacore 40300-30-6A. The OEM -001 numbers are 29 in, -002 are 51 in, and -003 are mixed lengths, so confirm the 3 ft (0.9 m) length suits your application. For snap-style electrodes only, IPR Medical also stocks the compatible 2106395-001 6-lead snap set.


Why Source ECG Leadwires from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. Our compatible Multi-Link leadwires come in 3-, 5-, and 6-lead configurations with snap and grabber ends, so biomedical and materials teams can standardize accessories across GE CARESCAPE and ApexPro fleets at lower cost than OEM. Our team can help match lead sets to your trunk cables and support your monitors with in-house repair services.

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE patient monitors and ApexPro telemetry. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.