GE Healthcare 2016032-001 Compatible 10-Lead Multi-Link ECG Leadwire Set, 4 mm Banana Ends, Individual Leads, AHA
The GE Healthcare 2016032-001 compatible 10-lead ECG leadwire set (SKU EKL-MQS10-B-A) is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 10-lead banana leadwire set, built to match the original’s fit, form, and function.
| Lead Type | GE Multi-Link, Individual Leads |
| Lead Count | 10 Leads (12-Lead ECG) |
| Electrode End | 4 mm Banana |
| Color Code | AHA (US) |
| Lead Lengths | Limb 3.9 ft (1.2 m), Chest (V) 2.6 ft (0.8 m) |
| Patient Size | Adult/Pediatric |
| Lifecycle | Reusable |
| Replaces | GE Healthcare 2016032-001, 2104724-001, 2104724-005 |
Works with: the GE CAM 14 acquisition module, select GE MAC electrocardiographs (MAC 400 through MAC 5500 HD and MAC VU360), CASE stress systems, and CARESCAPE B450, B650, and B850 monitors. See the Specifications tab for the full list. Browse more ECG/EKG cables and accessories from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for GE diagnostic ECG and patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | EKL-MQS10-B-A |
| OEM Reference | GE Healthcare 2016032-001 |
| Lead Type | GE Multi-Link |
| Lead Count | 10 Leads (12-Lead ECG) |
| Lead Placement | Limb + Chest (RA, LA, LL, RL, V1–V6) |
| Color Code | AHA (US) |
| Module-End Connector | Individual Leads, Twin-Pin, Straight |
| Patient-End Connector | 4 mm Banana |
| Limb Lead Length | 3.9 ft (1.2 m) |
| Chest (V) Lead Length | 2.6 ft (0.8 m) |
| Shielding | Shielded |
| Cable Jacket | TPU, Gray |
| Lead Diameter | 0.12 in (3.0 mm) |
| Patient Size | Adult/Pediatric |
| Lifecycle | Reusable |
| Latex-Free | Yes |
| Sterile | No |
| Packaging | 1 Set per Bag |
| Weight | 0.4 lbs |
Compatible Equipment Models
| Manufacturer | Compatible Models |
| GE Healthcare / Marquette | CAM 14 Acquisition Module |
| GE Healthcare / Marquette | MAC 400, MAC 500, MAC 600, MAC 800, MAC 1000, MAC 1100, MAC 1200, MAC 1600, MAC 2000, MAC 3500 |
| GE Healthcare / Marquette | MAC 5000, MAC 5000ST, MAC 5500, MAC 5500 HD, MAC VU360 |
| GE Healthcare / Marquette | CASE Series, CASE 8000, CASE P2 |
| GE Healthcare / Marquette | CardioSmart, CardioSoft, CardioSys, Microsmart M |
| GE Healthcare | CARESCAPE B450, B650, B850 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| GE Healthcare | 2016032-001 |
| GE Healthcare | 2104724-001 |
| GE Healthcare | 2104724-005 (OEM is gold-plated) |
| Unimed | MQB10-LB |
| Aftermarket Equivalent | EKL-MQ10-B-A |
IPR Medical buys, sells, repairs, and stocks parts for GE MAC resting ECG systems, CAM 14 acquisition modules, and CARESCAPE monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the GE 2016032-001 Compatible 10-Lead ECG Leadwire Set?
The GE Healthcare 2016032-001 compatible 10-lead ECG leadwire set is a reusable, aftermarket set of 10 individual Multi-Link leads for diagnostic 12-lead ECG. Each lead runs from an electrode adapter on the patient to its own position on the CAM 14 acquisition module or Multi-Link input, which gathers the signals for the electrocardiograph, stress system, or monitor. Because the leads are individual, a single damaged lead is easy to identify. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 2016032-001 leadwire set.
Compatible Equipment Models
This compatible leadwire set is confirmed for use with the GE Marquette CAM 14 acquisition module and a broad range of GE MAC electrocardiographs: the MAC 400, 500, 600, 800, 1000, 1100, 1200, 1600, 2000, 3500, 5000, 5000ST, 5500, 5500 HD, and VU360. It also fits CASE Series, CASE 8000, and CASE P2 stress systems, the CardioSmart, CardioSoft, CardioSys, and Microsmart M systems, and GE CARESCAPE B450, B650, and B850 patient monitors. This set uses Multi-Link connectors and is not for the AM4/AM5 modules on older MAC 12 and MAC 15 systems, which use a different leadwire connection.
Design and Construction
The four limb leads are 3.9 ft (1.2 m) long to reach the arms and legs, and the six chest leads are 2.6 ft (0.8 m) long to reduce slack across the precordium. Each lead is shielded to keep the diagnostic ECG clean in busy exam rooms and stress labs. At the module end, each lead has a straight twin-pin Multi-Link connector that seats into its own labeled position. At the patient end, each lead has a 4 mm banana tip that accepts banana-style electrode adapters, so staff can match the snap, tab, or clip adapter to the electrodes in use. The leads follow the AHA color code for all 10 positions. The gray TPU jacket is about 0.12 in (3.0 mm) in diameter and stays flexible through repeated cleaning. The set is latex-free, non-sterile, rated for adult and pediatric use, weighs about 0.4 lbs, and ships as one set per bag.
When to Replace Your GE Multi-Link Leadwire Set
Diagnostic ECG leadwires are handled on every patient and flex constantly at both ends. Replace the set when one or more leads show noise, baseline wander, or lead-off messages with good electrode contact, when a banana tip no longer grips its adapter firmly, when a Multi-Link connector no longer seats securely, or when you find cracked jackets, exposed shielding, or faded color coding. A single failing lead can distort the recorded 12-lead ECG or cause a lead to be flagged as missing, so many departments replace the full set at the first sign of wear.
Cross Reference and Interchange Part Numbers
This compatible 10-lead Multi-Link leadwire set, IPR Medical SKU EKL-MQS10-B-A, cross-references to GE Healthcare part numbers 2016032-001, 2104724-001, and 2104724-005 (the OEM version of 2104724-005 has gold-plated contacts). It also interchanges with Unimed MQB10-LB and aftermarket equivalent EKL-MQ10-B-A. Materials managers and purchasing staff can use any of these numbers to confirm the match against existing inventory, work orders, or requisitions. For the CAM 14 interface cable, IPR Medical also stocks the compatible GE 2016560-001 and 2016560-003 cables, along with the GE 900178-001 banana electrode adapter set.
Why Source ECG Leadwires from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for diagnostic ECG, patient monitoring, and infusion equipment. Our compatible leadwires, interface cables, and adapters give cardiology and biomedical departments an affordable alternative to OEM accessories while matching OEM fit and function across GE MAC, CASE, and CARESCAPE fleets. Our team can help assemble the right leadwire, adapter, and cable combination for your systems and support your equipment with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for GE MAC resting ECG systems, CAM 14 acquisition modules, and CARESCAPE monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.