Nihon Kohden BR-903PA Compatible 3-Lead ECG Leadwire, Grabber/Pinch, AHA, Molded, 3.0 ft (0.9 m)
The Nihon Kohden BR-903PA compatible 3-lead ECG leadwire (SKU EL-NKB3-90G-A) is a reusable aftermarket replacement (not OEM) with grabber/pinch electrode ends, AHA color coding, and a 3.0 ft (0.9 m) length, in the Nihon Kohden BR-9XXP lead type.
| Lead Count | 3-Lead |
| Electrode End | Grabber/Pinch |
| AHA/IEC Code | AHA |
| Cable Length | 3.0 ft (0.9 m) |
| Lifecycle | Reusable |
| Replaces | Nihon Kohden BR-903PA |
Works with: select Nihon Kohden BSM, Life Scope, PVM, and TEC models, plus select Skanray / Larsen & Toubro models. See the Specifications tab for the full list. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EL-NKB3-90G-A |
| Replaces OEM Part | Nihon Kohden BR-903PA |
| Category | Cables & Sensors > ECG/EKG |
| Product | ECG Leadwire |
| Lead Count | 3-Lead |
| Lead Placement | Limb Lead |
| Electrode End | Grabber/Pinch |
| AHA/IEC Code | AHA (RA white, LA black, LL red) |
| Distal Connector | Molded |
| Feature | Shielded |
| Lead Type | Nihon Kohden (BR-9XXP) |
| Cable Length | 3.0 ft (0.9 m) |
| Intended Use | Monitoring |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Nihon Kohden | BSM-73, BSM-73C, BSM-230K, BSM-1101, BSM-1101K, BSM-1102, BSM-1102K, BSM-1700 Series, BSM-2000, BSM-2101, BSM-2102, BSM-2300, BSM-2300 Life Scope I, BSM-2300 Series, BSM-2300 with YJ 230P, BSM-2300C, BSM-2301, BSM-2301C, BSM-2303, BSM-2303C, BSM-2304, BSM-2351, BSM-2351C, BSM-2353, BSM-2353C, BSM-2354A, BSM-3000, BSM-3000 Series, BSM-3000 with AY 631P, BSM-3000 with AY 633P, BSM-3000 with AY 651P, BSM-3000 with AY 653P, BSM-3101, BSM-3500, BSM-3532, BSM-3552, BSM-3562, BSM-3700, BSM-3733, BSM-3753, BSM-3763, BSM-4100, BSM-4100 Life Scope P, BSM-4100 Series, BSM-4101, BSM-4101K, BSM-4102, BSM-4103, BSM-4103K, BSM-4104, BSM-4111, BSM-4111K, BSM-4112, BSM-4113, BSM-4113K, BSM-4114, BSM-5000 Series, BSM-5100, BSM-5100 Life Scope A, BSM-5100 Series, BSM-5100 with YJ 510P, BSM-5105, BSM-5105K, BSM-5135, BSM-5135K, BSM-6000 Series, BSM-6000 with AY 631P, BSM-6000 with AY 633P, BSM-6000 with AY 651P, BSM-6000 with AY 653P, BSM-6301, BSM-6301C, BSM-6301K, BSM-6311, BSM-6312, BSM-6312-NKFL/ZA, BSM-6313, BSM-6331, BSM-6332, BSM-6333, BSM-6501, BSM-6501C, BSM-6501K, BSM-6531, BSM-6532, BSM-6533, BSM-6571, BSM-6572, BSM-6573, BSM-6701, BSM-6701C, BSM-6701K, BSM-6731, BSM-6732, BSM-6733, BSM-6771, BSM-6772, BSM-6773, BSM-7100, BSM-7102A, BSM-7200, BSM-7201K, BSM-7211K, BSM-8200, BSM-8201, BSM-8300, BSM-8301, BSM-8301A, BSM-8302, BSM-8302A, BSM-8500, BSM-8500A, BSM-8502, BSM-8502A, BSM-8800, BSM-8800A, BSM-9100, BSM-9100 with AY 631P, BSM-9100 with AY 633P, BSM-9100 with AY 651P, BSM-9100 with AY 653P, BSM-9100 with YJ 671P, BSM-9101, BSM-9172, BSM-9173, BSM-9510, BSM-9510 Life Scope M, BSM-9510K, BSM-9800 Life Scope S, BSS 9800K, Life Scope 6700 Series, Life Scope LC BSM-3101K, Life Scope SVM 7200 Series, Life Scope TR, Lifescope G Series, Lifescope GZ-130, Lifescope GZ-140, Lifescope GZ-140P, NTX ZM-540/541P, PVM 2700, PVM 2703, PVM-2701, TEC 5500, TEC 7700, TEC 8300, Vismo PVM 2701, Vismo PVM 2703, ZM 920PG, ZM 930PG, ZM 940PG, ZM-520-PA, ZM-521-PA, ZM-530-PA, ZM-531-PA, ZM-900 Series Transmitters, ZS 530PG, ZS 910PG, ZS 920PG, ZS 930PG, ZS 940PG |
| Skanray / Larsen & Toubro | Galaxy, Planet 55, Star 50, Star 55 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Nihon Kohden | K911A, BR-903PA, BR-903P |
| AMC | LW-3810029/3A |
| Curbell | LDW-03BF-29AN-0000 |
| Sage | L07-03-29P |
| Skanray / Larsen & Toubro | LALW-3810029/3A |
| Unimed | NKB3-90P |
IPR Medical buys, sells, repairs, and stocks parts for Nihon Kohden ECG leadwires and the monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, or any other manufacturer or supplier named on this page. Nihon Kohden, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Nihon Kohden BR-903PA Compatible 3-Lead ECG Leadwire?
The IPR Medical EL-NKB3-90G-A is a compatible aftermarket (not OEM) 3-lead ECG leadwire that replaces the Nihon Kohden BR-903PA. It is a reusable limb-lead leadwire with grabber/pinch electrode ends, AHA color coding, and a 3.0 ft (0.9 m) length, and its lead type is listed as Nihon Kohden BR-9XXP. It is intended for ECG monitoring.
Compatible Monitor Models
Listed compatible equipment for the EL-NKB3-90G-A includes select Nihon Kohden BSM models such as the BSM-2301, BSM-4100 Series, BSM-6000 Series, and BSM-9510, select Life Scope models including the Life Scope TR and Life Scope 6700 Series, and select PVM, TEC, ZM, and ZS models. Select Skanray / Larsen & Toubro models, including the Galaxy, Planet 55, Star 50, and Star 55, are also listed. Several BSM entries are listed together with YJ or AY part numbers, and those configurations appear in the table exactly as listed. Confirm your monitor in the Compatible Monitor Models table on the Specifications tab before ordering.
Design and Construction
This leadwire has three leads for limb placement, each finished with a grabber/pinch electrode end, and it follows AHA color coding (RA white, LA black, LL red). It is a shielded leadwire with a molded distal connector and an overall length of 3.0 ft (0.9 m). Because it is reusable, the leadwire can be cleaned between patients per facility protocol and kept in service while it passes inspection. It ships one per bag.
When to Replace Your 3-Lead ECG Leadwire
Replace the leadwire when the insulation is cracked, cut, or kinked, when a grabber no longer closes firmly on the electrode, or when the connector shows bent pins or other damage. Noisy or wandering ECG traces, frequent lead-off alarms, and artifact that appears whenever the leads are moved are also common signs of wear. Swapping in a known-good leadwire on the same monitor is a quick way for biomedical staff to confirm the fault.
Cross Reference and Interchange Part Numbers
This compatible leadwire replaces the Nihon Kohden BR-903PA and also cross-references to Nihon Kohden BR-903P and K911A and to Skanray / Larsen & Toubro LALW-3810029/3A. The remaining interchange numbers are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source ECG Leadwires from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our technicians repair and test monitors in-house, so we can help you match leadwires to the Nihon Kohden monitors in your facility and keep those monitors in service. Browse more ECG cables and leadwires, or call 855-477-8866 for help with ordering, repairs, or parts.
IPR Medical buys, sells, repairs, and stocks parts for Nihon Kohden ECG leadwires and the monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, or any other manufacturer or supplier named on this page. Nihon Kohden, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.

















