Nellcor OxiMax Compatible Adult Finger Clip SpO2 Sensor, Reusable, 9.8 ft (3.0 m)
Nellcor OxiMax Compatible Adult Finger Clip SpO2 Sensor (SKU SS-003XC-AF30) is a compatible aftermarket replacement (not OEM) for Nellcor OxiMax adult finger clip sensors. It is a reusable hard-shell adult finger clip sensor with a 9.8 ft (3.0 m) cable.
| Replaces | Nellcor OxiMax adult finger clip sensors |
| Sensor Type | Finger Clip (Hard Shell) |
| Patient Size | Adult |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
Works with: select Nellcor, Mindray and Datascope, GE Healthcare Dinamap and Carescape, Welch Allyn, Midmark and Cardell, and other monitors. See the Specifications tab for the full compatibility list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-003XC-AF30 |
| Replaces OEM Part | Nellcor OxiMax adult finger clip sensors (no single OEM part number listed) |
| Category | Cables & Sensors > SpO2 |
| Product | SpO2 Sensor |
| Sensor Type | Finger Clip (Hard Shell) |
| Patient Size | Adult |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| CAS Medical Systems (CASMED) | 511, 740 |
| Cardio Aid | 200 |
| Criticare / CSI | 506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506N3, 506NV3, 506NVP3 |
| Datex-Ohmeda | Cardiocap/5, enGuard CM5 |
| Digicare | LW600 |
| DRE | Waveline |
| Edan (with Nellcor OxiMax SpO2 Option) | elite V5, elite V6, elite V8 |
| Fukuda Denshi | Dynascope DS-7100 |
| GE Healthcare / Critikon Dinamap | Carescape B650, Carescape V100, E-NSAT, M-NSAT Module, Pro 200, Pro 300, Pro 300V2, Pro 400, Pro 1000, Pro 1000 V3, Pro Series, Pro Series V2, ProCare, ProCare 100, ProCare 200, ProCare 300, ProCare 400, ProCare Auscultatory 400, V300 |
| Invivo | 200, Escort II OPT30 Prism, MDE Escort Prism, T8 |
| Ivy Biomedical | 450C, 700, CM5 |
| Mediana | M30, YM1000, YM6000 |
| Midmark / Cardell | 9403, 9500HD |
| Mindray / Datascope | Accutorr Plus, Accutorr V, Duo, EPM4, Passport 2, Passport 2LT, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V-Series, V12, V21 |
| Mindray / Datascope (with Nellcor OxiMax SpO2 Option) | Accusat, Accutorr Plus, Accutorr V, Duo, Passport 2, Passport 2LT, Passport V, Spectrum, Spectrum OR, Trio, V12, V21 |
| Nellcor (Covidien) | Capnostream 20p, Capnostream 35, N-390, N-395, N-550, N-560, N-595, N-600, N-600x, N-3000, N-5500, N-5600 Plus, N-6000, NPB-290, NPB-295, PM100N, PM1000N, Symphony N-3000 |
| Nihon Kohden | BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100 |
| Omron / Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, BP-S510, Press-Mate, T105NXM |
| Oridion | Capnostream 20 |
| Philips | Prodigy, VS1 |
| Physio-Control | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
| Respironics | Alice 5 |
| Welch Allyn | 1500, 42NT0-E1 LXi, 45NE0-E1 LX, 53STP, 71WT-B Connex Spot, 73CE-B, 73CT-B, 74CE-B, 74CT-B, 74CX-B, 75CE-B, 75CT-B, Connex 6000 Series, Propaq CS, Spot Vital Signs 42MTB-E1, Spot Vital Signs 42NTB-E1, Spot Vital Signs LXi |
| Zoll | E Series, M Series, R Series |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Praymed | PSA0001-L, PSA0117-L |
| Unimed | U410-70P |
IPR Medical buys, sells, repairs, and stocks parts for SpO2 sensors and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Nellcor OxiMax Compatible Adult Finger Clip SpO2 Sensor?
The IPR Medical SS-003XC-AF30 is a compatible aftermarket adult finger clip SpO2 sensor (not an OEM part) built for Nellcor OxiMax pulse oximetry. It is a reusable hard-shell clip that fits on the patient’s finger and measures oxygen saturation and pulse rate for display on a compatible monitor. Its 9.8 ft (3.0 m) cable gives clinicians room to position the patient and route the cable at the bedside.
Compatible Monitor Models
This sensor is listed as compatible with select Nellcor pulse oximeters and Capnostream monitors, select Mindray and Datascope Passport, Spectrum, Trio, Duo, Accutorr, and V-Series monitors, select GE Healthcare Dinamap, ProCare, and Carescape monitors, select Welch Allyn Spot Vital Signs, Connex, and Propaq models, select Midmark and Cardell monitors, and select Criticare, Nihon Kohden, Omron and Colin, Physio-Control Lifepak, Zoll, and other monitors. Datascope Accusat and Edan elite V5, V6, and V8 monitors are listed only when equipped with the Nellcor OxiMax SpO2 option, and several Mindray and Datascope models are listed both as standard and with that option, so they appear in both rows of the table. See the Compatible Monitor Models table on the Specifications tab for the complete list, and confirm your monitor model and SpO2 option before ordering.
Design and Construction
The sensor uses a hard-shell finger clip sized for adult patients and is designed around Nellcor OxiMax SpO2 technology. It has a 9.8 ft (3.0 m) cable and ships one per bag. As a reusable sensor, it can be cleaned between patients per facility protocol and the manufacturer’s instructions for your monitor, and kept in service as long as it passes inspection.
When to Replace Your Adult Finger Clip SpO2 Sensor
Replace the sensor when you see a cracked or broken clip housing, a hinge that no longer holds the clip closed on the finger, damaged or cloudy sensor windows, a cracked or split cable jacket, or bent or damaged pins at the monitor connector. Erratic or intermittent SpO2 readings, frequent sensor-off or no-signal alarms, or readings that drop out when the cable is moved are also common signs of a failing sensor. Trying a known-good sensor is a quick way for biomedical staff to isolate whether the sensor or the monitor is at fault.
Cross Reference and Interchange Part Numbers
This sensor is offered as a compatible replacement for Nellcor OxiMax adult finger clip sensors rather than against a single Nellcor OEM part number. Interchange part numbers for equivalent compatible sensors are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our in-house technicians service patient monitoring equipment, so we can help you confirm the right sensor for your equipment and keep your fleet in service. Browse more SpO2 cables, sensors, and accessories in our SpO2 category, or call 855-477-8866 for help with ordering, repairs, or parts.
IPR Medical buys, sells, repairs, and stocks parts for SpO2 sensors and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.