IPR Medical

Nellcor DOC-10 Compatible SpO2 Adapter Cable for OxiMax Sensors, Reusable, 9.8 ft (3.0 m)

$60.00

Nellcor DOC-10 Compatible SpO2 Adapter Cable (SKU SA-003X-30) is a compatible aftermarket replacement (not OEM) for the Nellcor DOC-10. It is a reusable 9.8 ft (3.0 m) adapter cable for use with Nellcor OxiMax SpO2 sensors.

Replaces Nellcor DOC-10
SpO2 Technology Nellcor OxiMax
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable

Works with: select Nellcor, Mindray and Datascope, GE Healthcare Dinamap and Carescape, Welch Allyn, Midmark and Cardell, and other monitors. See the Specifications tab for the full compatibility list.

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: SA-003X-30 Categories: , Tags: ,
Send In Nellcor DOC-10 Compatible SpO2 Adapter Cable for OxiMax Sensors, Reusable, 9.8 ft (3.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SA-003X-30
Replaces OEM Part Nellcor DOC-10
Category Cables & Sensors > SpO2
Product SpO2 Adapter Cable (for use with OxiMax Sensors)
SpO2 Technology Nellcor OxiMax
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Bitmos sat 800, sat 801, sat 805, sat 816, satPuls
CAS Medical Systems (CASMED) 511, 740
Criticare / CSI 506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3
Datex-Ohmeda Cardiocap/5, enGuard CM5
Digicare LW600
DRE Waveline
Edan iM20
Edan (with Nellcor OxiMax SpO2 Option) elite V5, elite V6, elite V8
Fukuda Denshi Dynascope DS-7100, Dynascope DS-8100
GE Healthcare / Critikon Dinamap Carescape B650, Carescape V100, E-NSAT, M-NSAT Module, Pro 110, Pro 200, Pro 210, Pro 300, Pro 300V2, Pro 310, Pro 400, Pro 410, Pro 1000, Pro 1000 V3, Pro Series, Pro Series V2, ProCare, ProCare 100, ProCare 200, ProCare 300, ProCare 320, ProCare 400, ProCare 400V2, ProCare 420, ProCare Auscultatory 400, V300
Invivo 200, Escort II OPT30 Prism, MDE Escort Prism
Ivy Biomedical 450C, 700, CM5
Mediana M20, YM1000, YM6000
Midmark / Cardell 8019, 8019-001, 8019-002, 8019-003, 8020, 9402, 9403, 9405, 9405V, 9454 (Vet), 9500, 9500HD, MAX-12, Touch, Touch 8013
Mindray / Datascope Accutorr, Accutorr 5, Accutorr Plus, Accutorr V, Duo, EPM4, Passport 2, Passport 2LT, Passport V, Passport XG, Spectrum, Spectrum OR, T8, Trio, V-Series, V12, V21
Mindray / Datascope (with Nellcor OxiMax SpO2 Option) Accusat, Accutorr Plus, Accutorr V, Duo, Passport 2, Passport 2LT, Passport V, Spectrum, Spectrum OR, Trio, V12, V21
Mortara Surveyor S12/S19
Nellcor (Covidien / Medtronic) Capnostream 20p, Capnostream 35 (PM35MN), N-390, N-395, N-550, N-560, N-595, N-600, N-600x, N-3000, N-5500, N-5600 Plus, N-6000, NPB-290, NPB-295, PM100N, PM1000N, Symphony N-3000
Nihon Kohden BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100
Omron / Colin BP-306, BP-508, BP-808, BP-88, BP-88S, BP-S510, Press-Mate, T105NXM
Oridion Capnostream 20
Philips Prodigy, VS1
Physio-Control Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E
Respironics Alice 5
Welch Allyn 1500, 42NT0-E1 LXi, 45NE0-E1 LX, 53STP, 64N Series, 65N Series, 67N Series, 68M Series, 68N Series, 71WT-B Connex Spot, 73C Series, 74C Series, 901058, Connex 6000 Series, Propaq CS, Spot Vital Signs 42MTB-E1, Spot Vital Signs 42NTB-E1, Spot Vital Signs LXi
Zoll E Series, M Series, R Series

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Nellcor (Covidien) DOC-10, DOC10
AIV CB-10639
AMC (Advantage Medical) CB-A400-1011DO
Baxter CMANELLEP
Beta Biomed B400-1011B
CAS Medical Systems (CASMED) 01-02-0183, 01-04-0132
Comen 040-000243-00
Curbell 5574
Draeger MS20979
Edan 01.57.471069-10
Fukuda Denshi 1M1120
GE Healthcare (Marquette, Critikon, Datex-Ohmeda) 2008773-001, 2059001-001, OMN00122, OMEA0088
Huntleigh ACC-NEL-DOC10, 320325-1
Ivy Biomedical 590308
Maxtec DOC10C
Midmark / Cardell 01-02-0183
Mindray / Datascope 0012-00-1464, 0012-1464-10
Pacific Medical NXNE500
Sage E06X-30M
Spacelabs 010-2192-00
Tenacore TE1725, TCEO-0109-1221
Unimed U710-70
Welch Allyn WA-DOC-10

IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Nellcor DOC-10 Compatible SpO2 Adapter Cable?

The IPR Medical SA-003X-30 is a compatible aftermarket SpO2 adapter cable that replaces the Nellcor DOC-10 (not an OEM part). It is built for use with Nellcor OxiMax SpO2 sensors, linking the sensor to a compatible monitor so pulse oximetry readings reach the bedside display. At 9.8 ft (3.0 m), it gives clinicians room to position the patient and route the cable without pulling on the sensor.


Compatible Monitor Models

This adapter cable is listed as compatible with select Nellcor pulse oximeters and Capnostream monitors, select Mindray and Datascope Passport, Spectrum, Trio, Duo, Accutorr, and V-Series monitors, select GE Healthcare Dinamap, ProCare, and Carescape monitors, select Welch Allyn Spot Vital Signs, Connex, and Propaq models, select Midmark and Cardell monitors, and select Criticare, Edan, Nihon Kohden, Omron and Colin, Physio-Control Lifepak, Zoll, and other monitors. Datascope Accusat and Edan elite V5, V6, and V8 monitors are listed only when equipped with the Nellcor OxiMax SpO2 option, and several Mindray and Datascope models are listed both as standard and with that option, so they appear in both rows of the table. See the Compatible Monitor Models table on the Specifications tab for the complete list, and confirm your monitor model and SpO2 option before ordering.


Design and Construction

The cable is a reusable SpO2 adapter cable designed around Nellcor OxiMax SpO2 technology. It measures 9.8 ft (3.0 m) end to end and ships one per bag. As a reusable accessory, it can be cleaned between patients per facility protocol and the manufacturer’s instructions for your monitor, and kept in service as long as it passes inspection.


When to Replace Your SpO2 Adapter Cable

Replace the adapter cable when you see a cracked or split jacket, exposed conductors, bent or damaged pins at either connector, a loose or wobbly connection at the monitor or sensor, or kinks that do not relax. Intermittent SpO2 readings, frequent sensor-off or no-signal alarms, or readings that drop out when the cable is moved are also common signs of a failing cable. Swapping in a known-good cable is a quick way for biomedical staff to isolate whether the cable, the sensor, or the monitor is at fault.


Cross Reference and Interchange Part Numbers

This compatible cable replaces Nellcor DOC-10 (also listed as DOC10). It also cross-references to Mindray and Datascope 0012-00-1464 and 0012-1464-10, GE Healthcare 2008773-001, 2059001-001, OMN00122, and OMEA0088, Welch Allyn WA-DOC-10, Draeger MS20979, Huntleigh ACC-NEL-DOC10 and 320325-1, CAS Medical Systems 01-02-0183 and 01-04-0132, Midmark and Cardell 01-02-0183, Edan 01.57.471069-10, Fukuda Denshi 1M1120, Spacelabs 010-2192-00, Ivy Biomedical 590308, Comen 040-000243-00, Baxter CMANELLEP, and Curbell 5574. Additional interchange numbers are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.


Why Source SpO2 Adapter Cables from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our in-house technicians service patient monitoring equipment, so we can help you confirm the right cable for your equipment and keep your fleet in service. Browse more SpO2 cables, sensors, and accessories in our SpO2 category, or call 855-477-8866 for help with ordering, repairs, or parts.

IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.