Masimo 2258 (LNCS Y-I) Compatible Multi-Site Y SpO2 Sensor, All Patient Sizes, Reusable, 3.3 ft (1.0 m)
The Masimo 2258 (LNCS Y-I) compatible SpO2 sensor (SKU SS-005RB-MY10) is a reusable, aftermarket replacement (not OEM) multi-site Y sensor for Masimo SET-equipped monitors, built to match the original’s fit, form, and function. One sensor covers neonatal through adult patients on the foot, hand, finger, or toe.
| Sensor Type | Multi-Site Y |
| Patient Size | All Sizes (Neonatal through Adult) |
| Connector | Masimo LNCS |
| SpO2 Technology | Masimo SET (LNCS) |
| Cable Length | 3.3 ft (1.0 m) |
| Lifecycle | Reusable |
| Replaces | Masimo 2258, Draeger MP00789, Datascope 0010-10-43016, and more |
Works with: Masimo Radical-7, Rad-5, Rad-8, and Rad-57; Masimo SET-equipped Mindray/Datascope Passport and Spectrum, GE Dash, Solar, CARESCAPE, and Dinamap, Philips IntelliVue, Physio-Control Lifepak 11 through 20e, Zoll E, M, R, and X Series, Draeger Infinity, Welch Allyn Connex Spot, Propaq, and Spot Vital Signs monitors, and the Datex-Ohmeda Giraffe Infant Warmer. Some monitors require an LNCS patient cable. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-005RB-MY10 |
| Replaces OEM Part | Masimo 2258 (LNCS Y-I) |
| Category | Reusable SpO2 Sensor |
| Sensor Type | Multi-Site Y |
| Patient Size | All Sizes (Neonatal through Adult) |
| Cable Length | 3.3 ft (1.0 m) |
| Connector | Masimo LNCS |
| SpO2 Technology | Masimo SET (LNCS) |
| Lifecycle | Reusable |
| Packaging | 1 Set per Bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Masimo | 9216, 9226, Pronto-7, R7CDS-1, Rad-5, Rad-8, Rad-57, Rad-87, Radical-7 |
| Mindray / Datascope | Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision N1, BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision TD60, BeneVision TMS60, BeneVision TMS80, BeneHeart D6, cPM 8, cPM 12, DPM3, DPM4, DPM5, DPM6, DPM7, Duo, EPM4, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM-9800, MEC 12, MPM, Passport 2, Passport 2LT, Passport 8, Passport 12, Passport 12m, Passport 17m, Passport V, Passport XG, PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, T8, Trio, V12, V21, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, VS 800 |
| GE Healthcare (Marquette) | Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, Eagle 1000, PDM Module, ProCare B40, Solar 7000, Solar 8000, Solar 8000M, i/9500 (Tram 451N5/851N5), Tram 451, TRAM Modular, x50SL Series, SMK SMV |
| GE Healthcare (Dinamap) | B105M, B105P, B125M, B125P, B155M, CARESCAPE B650, CARESCAPE B850, CARESCAPE V100, CARESCAPE VC150, ProCare with Masimo (Pro 1000, Pro 300V2, Pro 400V2), ProCare 300, ProCare Auscultatory 400, ProSeries V2, V300 |
| GE Healthcare (Corometrics) | 128, 250, 250cx, 259, TRAM 450SL |
| Datex-Ohmeda | Giraffe Infant Warmer, S/5 |
| Philips | Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A MP2, M8105A MP5, M8105AS, MP30, SureSigns VS2, SureSigns VS3, VM4 |
| Physio-Control (Stryker) | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20e |
| Zoll | E Series, M Series, R Series, X Series |
| Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400 |
| Welch Allyn | 1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, 64H Series, 64M Series, 65H Series, 65M Series, 67M Series, 68M Series, 73ME-B, 73MT-B, 74ME-B, 74MT-B, 74MX-B, 75MT-B Connex Spot, 75ME-B, 75MX-B, Propaq CS, Propaq LT, Series 420, Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi, Vital Signs 4700 Series |
| Invivo | Escort II OPT30 Prism, T8 |
| Respironics | Alice 5, Alice 6 |
| CASMed | 740 |
| Natus | Connex |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| Comen | K12 Pro |
| Mennen | Horizon XVu |
| Penlon InterMed | Masimo SET-Equipped Models |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2258 (LNCS Y-I) |
| Datascope (Mindray) | 0010-10-43016 |
| Draeger | MP00789, MP03023 |
| Spacelabs | 690-0291-00 |
| Praymed | PSF0153-S, PSF0204-S |
| Sage | P109M-49M |
| Tenacore | TCPY-1404-0112, TY1515Y03 |
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2258 LNCS Y-I SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Compatible Masimo 2258 LNCS Y-I Multi-Site Sensor?
The Masimo 2258 (LNCS Y-I) compatible SpO2 sensor (IPR SKU SS-005RB-MY10) is a reusable multi-site Y sensor for monitors that use Masimo SET pulse oximetry with an LNCS sensor interface. It is a compatible aftermarket replacement, not an OEM Masimo product, built to match the fit, form, and function of the original Y-I sensor. The emitter and detector sit on separate flexible leads that split from a single cable in a “Y,” so they can be positioned on opposite sides of a foot, hand, finger, or toe. That makes one sensor usable across patient sizes from neonates to adults. The 3.3 ft (1.0 m) cable ends in a Masimo LNCS connector, which plugs directly into LNCS-equipped Masimo devices or into an LNCS patient cable on other brands’ monitors that use Masimo SET technology.
Compatible Monitor Models
This compatible sensor works across a very broad installed base of Masimo SET-equipped devices. Compatibility includes Masimo Radical-7, Rad-5, Rad-8, Rad-57, Rad-87, and Pronto-7; Mindray and Datascope Passport, Spectrum, Accutorr, BeneView, BeneVision, DPM, iMEC, VS, and PM series monitors; GE Healthcare Dash, Solar, Eagle, Tram, CARESCAPE B650, B850, V100, and VC150, and Dinamap B105, B125, B155, and ProCare monitors, plus Corometrics fetal monitors; Philips IntelliVue MP-series and M3001A MMS configurations, SureSigns VS2 and VS3, and Heartstream XL; Physio-Control Lifepak 11, 12, 15, 20, and 20e; Zoll E, M, R, and X Series; Draeger Infinity Delta, Kappa, M540, and Narkomed 6400; Welch Allyn Connex Spot, Propaq, Spot Vital Signs, and 4700 Series; and Datex-Ohmeda S/5 and Giraffe Infant Warmer. The Specifications tab lists every compatible model. Confirm that your device is configured for Masimo SET oximetry, and whether it requires an LNCS patient cable, before ordering.
Design and Construction
The Y design separates the emitter and detector onto two small, flexible heads, so they can be aligned directly across from each other on sites a clip cannot reach, such as a neonate’s foot or palm, an infant’s great toe, or an adult finger. The heads are secured with a wrap suited to the patient and site, following your facility’s application protocol. Because one reusable sensor covers neonatal, pediatric, and adult patients, the Y-I simplifies stocking on NICUs, PICUs, and mixed-acuity units. The 3.3 ft (1.0 m) cable terminates in a Masimo LNCS connector. The sensor is reusable and supplied as one set per bag.
When to Replace Your 2258 LNCS Y-I SpO2 Sensor
The thin leads on a Y sensor are the part most exposed to wear, especially where they split from the main cable. Replace the sensor when either lead is cut, kinked, or pulling away at the split, the emitter or detector face is cracked, scratched, or discolored, the LNCS connector is damaged or has bent pins, or the cable jacket shows cuts. Persistent “sensor off” alarms, low signal quality on a properly applied sensor, or readings that drop out when the cable is moved also point to a failing sensor. If a sensor fails to read on a monitor that passes self-test, try a known-good sensor and patient cable to isolate the fault quickly.
Cross Reference and Interchange Part Numbers
This compatible sensor cross-references to Masimo 2258 (LNCS Y-I), and to the OEM-labeled equivalents sold under other monitor brands, including Datascope 0010-10-43016, Draeger MP00789 and MP03023, and Spacelabs 690-0291-00. Aftermarket interchange numbers include Praymed PSF0153-S and PSF0204-S, Sage P109M-49M, and Tenacore TCPY-1404-0112 and TY1515Y03.
Why Source Masimo-Compatible SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment. Compatible reusable SpO2 sensors give NICUs, pediatric units, and materials managers a cost-effective way to keep Masimo SET-equipped monitors in service across multiple brands without paying OEM pricing. Our team can confirm fit against your monitor model and patient cable before you order, and we also offer in-house repair services, replacement parts, and refurbished equipment, so you can source accessories and service from a single partner.
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2258 LNCS Y-I SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.